Evaluation of A-SPECT: A desktop pinhole SPECT system for small animal Imaging

被引:0
|
作者
McElroy, DP [1 ]
MacDonald, LR [1 ]
Beekman, FJ [1 ]
Wang, YC [1 ]
Patt, BE [1 ]
Iwanczyk, JS [1 ]
Tsui, BMW [1 ]
Hoffman, EJ [1 ]
机构
[1] Univ Calif Los Angeles, Sch Med, Div Nucl Med & Biophys, Los Angeles, CA 90095 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Pinhole collimation of gamma rays to image distributions of radiolabeled tracers is considered promising for use in small animal imaging. The recent availability of transgenic mice, coupled with the development of I-125 and Tc-99m labeled tracers, has allowed the study of a range of human disease models while creating demand for ultra-high resolution imaging devices. We have developed a compact gamma camera that, in combination with pinhole collimation, allows for accessible, ultra-high resolution in vivo SPECT imaging of small animals. The system is based on a pixilated array of NaI(Tl) crystals coupled to an array of position sensitive photomultiplier tubes (PSPMTs). Interchangeable tungsten pinholes with diameters ranging from 0.5 mm to 3 mm are available, allowing the camera to be optimized for a variety of imaging situations. We use a 3D MLEM algorithm to reconstruct projection images, allowing for 3D positioning of isotope distributions. Our evaluation indicates that high quality, sub-millimeter spatial resolution images can be achieved in living mice. Reconstructed axial spatial resolution was measured to be 0.53 mm and 0.74 mm FWHM for rotation radii of 1 cm and 2 cm, respectively, using the 0.5 mm pinhole. In this configuration, sensitivity is comparable to that of a standard high resolution parallel hole collimator. SPECT images of hot and cold rod phantoms and a highly structured monkey brain phantom illustrate that high quality images can be obtained with the system. Images of living mice demonstrate the ability of the system to obtain high resolution images in vivo.
引用
下载
收藏
页码:1835 / 1839
页数:5
相关论文
共 50 条
  • [41] System Matrix Based on Sensitivity Model for Small Animal Multi-pinhole SPECT System
    Hsieh, Ho-Hui
    Hsu, Ching-Han
    Mok, Greta S. P.
    Tsai, Yu-Jung
    Chang, Shi-Ing
    Hsiao, Ing-Tsung
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3308 - 3311
  • [42] Integrated CT-SPECT system for small animal imaging
    Williams, MB
    Zhang, GM
    More, MJ
    Goode, AR
    Majewski, S
    Wojcik, R
    Kross, B
    Popov, V
    Weisenberger, AG
    Stanton, M
    Phillips, W
    Stewart, A
    McCauley, T
    Wu, T
    DiBella, EVR
    PENETRATING RADIATION SYSTEMS AND APPLICATIONS II, 2000, 4142 : 265 - 274
  • [43] A SMALL ANIMAL SYSTEM CAPABLE OF PET, SPECT AND PLANAR IMAGING
    GREEN, MV
    SEIDEL, J
    GANDLER, WR
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P61 - P61
  • [44] Compact CT/SPECT small-animal imaging system
    Kastis, GA
    Furenlid, LR
    Wilson, DW
    Peterson, TE
    Barber, HB
    Barrett, HH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (01) : 63 - 67
  • [45] Half-cone spect system for small animal imaging
    Li, Heng
    Zheng, Yibin
    Stolin, Alexander V.
    Kundu, Bijoy K.
    Williams, Mark B.
    2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 1236 - +
  • [46] ALBIRA: A small animal PET/SPECT/CT imaging system
    Sanchez, F.
    Orero, A.
    Soriano, A.
    Correcher, C.
    Conde, P.
    Gonzalez, A.
    Hernandez, L.
    Moliner, L.
    Rodriguez-Alvarez, M. J.
    Vidal, L. F.
    Benlloch, J. M.
    Chapman, S. E.
    Leevy, W. M.
    MEDICAL PHYSICS, 2013, 40 (05)
  • [47] Compact CT/SPECT small-animal imaging system
    Kastis, GA
    Furenlid, LR
    Wilson, DW
    Peterson, TE
    Barber, HB
    Barrett, HH
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 797 - 801
  • [48] Design and performance evaluation of a self-collimating SPECT system for small animal imaging
    Zhang, Debin
    Ma, Tianyu
    Lv, Zhenlei
    Wei, Qingyang
    Xu, Tianpeng
    Zhang, Hongyang
    Yao, Rutao
    Liu, Yaqiang
    He, Zuo-Xiang
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [49] A New Method for Submillimeter Desktop Small-Animal SPECT Imaging using Tilted Detector
    Zeraatakr, N.
    Rahmim, A.
    Sarkar, S.
    Ay, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S219 - S219
  • [50] Application of an ultra high-resolution pinhole SPECT system based on a conventional camera for small animal imaging.
    Tsui, BMW
    Wang, Y
    Frey, EC
    Wessell, DE
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 54P - 55P