Rotational Angiography Based Three-Dimensional Left Atrial Reconstruction: A New Approach for Transseptal Puncture

被引:7
|
作者
Koektuerk, Buelent [1 ]
Yorgun, Hikmet [1 ]
Koektuerk, Oezlem [1 ]
Turan, Cem H. [1 ]
Gorr, Eduard [1 ]
Horlitz, Marc [1 ]
Turan, Ramazan G. [1 ,2 ]
机构
[1] Univ Witten Herdecke, Krankenhaus Porz Rhein, Dept Cardiol Electrophysiol, D-51149 Cologne, Germany
[2] Univ Hosp Rostock, Dept Internal Med, Div Cardiol, Rostock, Germany
关键词
Atrial Fibrillation; Atrial Septum; Cardiac Imaging Techniques; Percutaneous Catheter Ablation; Rotational Angiography; Transseptal Puncture; FIBRILLATION ABLATION; X-RAY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; CATHETER ABLATION; PULMONARY VEINS; EFFICACY; SAFETY;
D O I
10.1111/1755-5922.12167
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AimRotational angiography is a well-known method for the three-dimensional (3-D) reconstruction of left atrium and pulmonary veins during left-sided atrial arrhythmia ablation procedures. In our study, we aimed to review our experience in transseptal puncture (TSP) using 3-D rotational angiography. MethodsWe included a total of 271 patients who underwent atrial fibrillation ablation using cryoballoon. Rotational angiography was performed to get the three-dimensional left atrial and pulmonary vein reconstructions using cardiac C-arm computed tomography. The image reconstruction was made using the DynaCT Cardiac software (Siemens, Erlangen, Germany). ResultsThe mean age of the study population was 6110years. The indications for left atrial arrhythmia ablation were paroxysmal AF in 140 patients (52%) and persistent AF patients in 131 (48%) patients. The success rate of TSP using only rotational guidance was (264/271 patients, 97.4%). In the remaining seven patients, transesophageal guidance was used after the initial attempt due to thick interatrial septum in five patients and difficult TSP due to abnormal anatomy and mild pericardial effusion in the remaining two patients. Mean fluoroscopy dosage of the rotational angiography was 4896.4 +/- 825.3Gym(2). The mean time beginning from femoral vein puncture to TSP was 12.3 +/- 5.5min. ConclusionTSP guided by rotational angiography is a safe and effective method. Our results indicate that integration of rotational angiographic images into the real-time fluoroscopy can guide the TSP during the procedure.
引用
收藏
页码:49 / 56
页数:8
相关论文
共 50 条
  • [31] Three-dimensional echocardiographic reconstruction of atrial membranes
    Samal, AK
    Nanda, NC
    Thakur, AC
    Aggarwal, R
    Jamil, F
    Kapur, G
    Aaluri, SR
    Moursi, M
    McGiffin, D
    Kirklin, J
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1998, 15 (06): : 605 - 610
  • [32] Computed Tomography Angiography with Three-Dimensional Reconstruction versus Rotational Angiography as a Screening Test in Patients with Suspected Cerebral Aneurysm
    Zarate Mendez, Antonio Maximiano
    Pena Rosas, Nadia Perez
    Lujan Guerra, Juan Carlos
    Garcia Mayagoitia, Antonio
    Betanzos Villegas, Aleixandre
    Lizararu Gutierrez, Eduardo Walter
    Cachon Camara, Gabriel Emmanuel
    Olvera Castro, Jorge Octavio
    Aceves Chimal, Jose Luis
    INDIAN JOURNAL OF NEUROSURGERY, 2016, 5 (02) : 95 - 100
  • [33] Left atrial appendage geometry and function using transesophageal three-dimensional echocardiography in atrial fibrillation: a new approach to characterize left atrial thrombogenic milieu
    Soulat-Dufour, L.
    Simon, T.
    Lang, S.
    Ederhy, S.
    Adavane-Scheuble, S.
    Chauvet-Droit, M.
    Capderou, E.
    Arnaud, C.
    Addetia, K.
    Lang, R.
    Scheuble, A.
    Hammoudi, N.
    Beraud, A.
    Boccara, F.
    Cohen, A.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [34] Reconstructing and Registering Three-Dimensional Rotational Angiogram of Left Atrium during Ablation of Atrial Fibrillation
    Tang, Min
    Kriatselis, Charalampos
    Ye, Gang
    Nedios, Sotiris
    Roser, Mathias
    Solowjowa, Natalia
    Fleck, Eckard
    Gerds-Li, Jin-Hong
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (11): : 1407 - 1416
  • [35] Transseptal puncture in left atrial appendage closure guided by 3D printing and multiplanar CT reconstruction
    Hozman, Marek
    Herman, Dalibor
    Zemanek, David
    Fiser, Ondrej
    Vrba, David
    Poloczek, Martin
    Varvarovsky, Ivo
    Obona, Peter
    Pokorny, Tomas
    Osmancik, Pavel
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2023, 102 (07) : 1331 - 1340
  • [36] Using three-dimensional rotational angiography for sizing of covered stents
    van den Berg, JC
    Overtoom, TTC
    de Valois, JC
    Moll, FL
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (01) : 149 - 152
  • [37] Three-dimensional rotational angiography image guidance for aneurysm surgery
    Raabe, A
    Seifert, V
    JOURNAL OF NEUROSURGERY, 2004, 100 (01) : A190 - A191
  • [38] THREE-DIMENSIONAL ROTATIONAL ANGIOGRAPHY IN MURINE MODELS: A TECHNICAL NOTE
    Ortiz-Velazquez, Rogelio Ivan
    Mendes Pereira Caldas, Jose Guilherme
    Rocha Lobo, Bruno Carmello
    Santos-Franco, Jorge Arturo
    Mercado-Pimentel, Rodrigo
    Revuelta, Rogelio
    CLINICS, 2009, 64 (12) : 1234 - 1236
  • [39] Feasibility of airway segmentation from three-dimensional rotational angiography
    Goreczny, Sebastian
    Haak, Alexander
    Morgan, Gareth John
    Zablah, Jenny
    CARDIOLOGY JOURNAL, 2020, 27 (06) : 875 - 878
  • [40] Effective radiation dosage of three-dimensional rotational angiography in children
    Peters, Marjolein
    Krings, Gregor
    Koster, Michel
    Molenschot, Mirella
    Freund, Mathhias W.
    Breur, Johannes M. P. J.
    EUROPACE, 2015, 17 (04): : 611 - 616