Rotational Angiography Based Three-Dimensional Left Atrial Reconstruction: A New Approach for Transseptal Puncture

被引:7
|
作者
Koektuerk, Buelent [1 ]
Yorgun, Hikmet [1 ]
Koektuerk, Oezlem [1 ]
Turan, Cem H. [1 ]
Gorr, Eduard [1 ]
Horlitz, Marc [1 ]
Turan, Ramazan G. [1 ,2 ]
机构
[1] Univ Witten Herdecke, Krankenhaus Porz Rhein, Dept Cardiol Electrophysiol, D-51149 Cologne, Germany
[2] Univ Hosp Rostock, Dept Internal Med, Div Cardiol, Rostock, Germany
关键词
Atrial Fibrillation; Atrial Septum; Cardiac Imaging Techniques; Percutaneous Catheter Ablation; Rotational Angiography; Transseptal Puncture; FIBRILLATION ABLATION; X-RAY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; CATHETER ABLATION; PULMONARY VEINS; EFFICACY; SAFETY;
D O I
10.1111/1755-5922.12167
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AimRotational angiography is a well-known method for the three-dimensional (3-D) reconstruction of left atrium and pulmonary veins during left-sided atrial arrhythmia ablation procedures. In our study, we aimed to review our experience in transseptal puncture (TSP) using 3-D rotational angiography. MethodsWe included a total of 271 patients who underwent atrial fibrillation ablation using cryoballoon. Rotational angiography was performed to get the three-dimensional left atrial and pulmonary vein reconstructions using cardiac C-arm computed tomography. The image reconstruction was made using the DynaCT Cardiac software (Siemens, Erlangen, Germany). ResultsThe mean age of the study population was 6110years. The indications for left atrial arrhythmia ablation were paroxysmal AF in 140 patients (52%) and persistent AF patients in 131 (48%) patients. The success rate of TSP using only rotational guidance was (264/271 patients, 97.4%). In the remaining seven patients, transesophageal guidance was used after the initial attempt due to thick interatrial septum in five patients and difficult TSP due to abnormal anatomy and mild pericardial effusion in the remaining two patients. Mean fluoroscopy dosage of the rotational angiography was 4896.4 +/- 825.3Gym(2). The mean time beginning from femoral vein puncture to TSP was 12.3 +/- 5.5min. ConclusionTSP guided by rotational angiography is a safe and effective method. Our results indicate that integration of rotational angiographic images into the real-time fluoroscopy can guide the TSP during the procedure.
引用
收藏
页码:49 / 56
页数:8
相关论文
共 50 条
  • [21] Three-dimensional rotational angiography of the left atrium and the oesophagus: the short-term mobility of the oesophagus and the stability of the fused three-dimensional model of the left atrium and the oesophagus during catheter ablation for atrial fibrillation
    Starek, Zdenek
    Lehar, Frantisek
    Jez, Jiri
    Scurek, Martin
    Wolf, Jiri
    Kulik, Tomas
    Zbankova, Alena
    Novak, Miroslav
    EUROPACE, 2017, 19 (08): : 1310 - 1316
  • [22] Assessment of distortion in a three-dimensional rotational angiography system
    Bridcut, RR
    Winder, RJ
    Workman, A
    Flynn, P
    BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (891): : 266 - 270
  • [23] Three-dimensional rotational angiography in children with an aortic coarctation
    Starmans, N. L. P.
    Krings, G. J.
    Molenschot, M. M. C.
    van der Stelt, F.
    Breur, J. M. P. J.
    NETHERLANDS HEART JOURNAL, 2016, 24 (11) : 666 - 674
  • [24] Three-dimensional rotational angiography in the diagnosis of cerebral aneurysms
    Capello, D
    Mavilio, N
    Allegretti, L
    Rosa, ML
    RIVISTA DI NEURORADIOLOGIA, 2003, 16 : 45 - 50
  • [25] New three-dimensional rendering image of transoesophageal echocardiography for second transseptal puncture for transcatheter mitral valve repair
    Nagura, Fukuko
    Kataoka, Akihisa
    Watanabe, Yusuke
    Kozuma, Ken
    EUROINTERVENTION, 2019, 15 (09) : E764 - +
  • [26] Vascular segmentation in three-dimensional rotational angiography based on maximum intensity projections
    Gan, R
    Chung, ACS
    Wong, WCK
    Simon, CHW
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, 2004, : 133 - 136
  • [27] Markov random field modeling for three-dimensional reconstruction of the left ventricle in cardiac angiography
    Medina, Ruben
    Garreau, Mireille
    Toro, Javier
    Breton, Herve L.
    Coatrieux, Jean-Louis
    Jugo, Diego
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (08) : 1087 - 1100
  • [28] Reconstruction of three-dimensional cardiac shapes in biplane angiography: a fuzzy and evolutionary approach
    Medina, R
    Garreau, M
    Navarro, C
    Coatrieux, JL
    Jugo, D
    COMPUTERS IN CARDIOLOGY 1999, VOL 26, 1999, 26 : 663 - 666
  • [29] Feasibility and safety of a three-dimensional anatomic map-guided transseptal puncture for left-sided catheter ablation procedures
    Bohnen, Marius
    Minners, Jan
    Eichenlaub, Martin
    Weber, Reinhold
    Allgeier, Hans-Juergen
    Jadidi, Amir
    Neumann, Franz-Josef
    Westermann, Dirk
    Arentz, Thomas
    Lehrmann, Heiko
    EUROPACE, 2023, 25 (03): : 1126 - 1134
  • [30] A case report of left ventricular lead implantation via total three-dimensional transseptal puncture after tricuspid valve replacement
    Gao, Jia
    Zhang, Nan
    Zhang, Binghang
    Sun, Meng
    Meng, Zhijun
    Guo, Min
    Wang, Rui
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10