An accurate method for correction of head movement in PET

被引:91
|
作者
Bühler, P
Just, U
Will, E
Kotzerke, J
van den Hoff, J
机构
[1] Tech Univ Dresden, Dept Nucl Med, D-01328 Dresden, Germany
[2] PET Ctr Rossendorf, D-01314 Dresden, Germany
关键词
motion compensation; motion measurement; positron emission tomography;
D O I
10.1109/TMI.2004.831214
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A method is presented to correct positron emission tomography (PET) data for head motion during data acquisition. The method is based on simultaneous acquisition of PET data in list mode and monitoring of the patient's head movements with a motion tracking system. According to the measured head motion, the line of response (LOR) of each single detected PET event is spatially transformed, resulting in a spatially fully corrected data set. The basic algorithm for spatial transformation of LORs is based on a number of assumptions which can lead to spatial artifacts and quantitative inaccuracies in the resulting images. These deficiencies are discussed, demonstrated and methods for improvement are presented. Using different kinds of phantoms the validity and accuracy of the correction method is tested and its applicability to human studies is demonstrated as well.
引用
收藏
页码:1176 / 1185
页数:10
相关论文
共 50 条
  • [41] Clinical evaluation of a head motion correction algorithm on PET/CT system
    Yang, W.
    Kang, F.
    Xie, Z.
    Li, G.
    Guo, K.
    Xi, C.
    Liu, H.
    Li, Y.
    Sun, C.
    Revilla, E. M.
    Zhao, Y.
    Zhang, D.
    Shi, L.
    Yi, H.
    Zhao, Y.
    Lu, Y.
    Wang, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S683 - S683
  • [42] Accurate attenuation correction in PET using short transmission scans and consistency information
    Welch, A
    Hallett, W
    Marsden, P
    Bromiley, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (03) : 427 - 432
  • [43] Feasibility of high-resolution head and neck PET/CT imaging while maintaining accurate PET quantitation
    Murata, Taisuke
    Iimori, Takashi
    Sawada, Koichi
    Umezawa, Tetsuro
    Masuda, Yoshitada
    Horikoshi, Takuro
    Uno, Takashi
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [44] Specific recommendations for accurate and direct use of PET-CT in PET guided radiotherapy for head and neck sites
    Thomas, C. M.
    Pike, L. C.
    Hartill, C. E.
    Baker, S.
    Woods, E.
    Convery, D. J.
    Greener, A. G.
    MEDICAL PHYSICS, 2014, 41 (04)
  • [45] Head movement measurement: An alternative method for posturography studies
    Ciria, L. F.
    Munoz, M. A.
    Gea, J.
    Pena, N.
    Miranda, J. G. V.
    Montoya, P.
    Vila, J.
    GAIT & POSTURE, 2017, 52 : 100 - 106
  • [46] Accurate Estimation Method of Arterial Wall Movement in Longitudinal Direction
    Iwamori, Koji
    Mori, Shohei
    Arakawa, Mototaka
    Kanai, Hiroshi
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 460 - 462
  • [47] Multidomain Fusion Method for Human Head Movement Recognition
    Bu, Yuqing
    Wang, Xiang
    Zhang, Bo
    Guo, Shisheng
    Cui, Guolong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [48] A method for accurate spatial registration of PET images and histopathology slices
    Tanuj Puri
    Anastasia Chalkidou
    Rhonda Henley-Smith
    Arunabha Roy
    Paul R. Barber
    Teresa Guerrero-Urbano
    Richard Oakley
    Ricard Simo
    Jean-Pierre Jeannon
    Mark McGurk
    Edward W. Odell
    Michael J. O’Doherty
    Paul K. Marsden
    EJNMMI Research, 5
  • [49] A method for accurate spatial registration of PET images and histopathology slices
    Puri, Tanuj
    Chalkidou, Anastasia
    Henley-Smith, Rhonda
    Roy, Arunabha
    Barber, Paul R.
    Guerrero-Urbano, Teresa
    Oakley, Richard
    Simo, Ricard
    Jeannon, Jean-Pierre
    McGurk, Mark
    Odell, Edward W.
    O'Doherty, Michael J.
    Marsden, Paul K.
    EJNMMI RESEARCH, 2015, 5 : 1 - 11
  • [50] An automatic method for accurate volume delineation of heterogeneous tumors in PET
    Hofheinz, F.
    Langner, J.
    Petr, J.
    Beuthien-Baumann, B.
    Steinbach, J.
    Kotzerke, J.
    van den Hoff, J.
    MEDICAL PHYSICS, 2013, 40 (08)