An accurate method for correction of head movement in PET

被引:91
|
作者
Bühler, P
Just, U
Will, E
Kotzerke, J
van den Hoff, J
机构
[1] Tech Univ Dresden, Dept Nucl Med, D-01328 Dresden, Germany
[2] PET Ctr Rossendorf, D-01314 Dresden, Germany
关键词
motion compensation; motion measurement; positron emission tomography;
D O I
10.1109/TMI.2004.831214
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A method is presented to correct positron emission tomography (PET) data for head motion during data acquisition. The method is based on simultaneous acquisition of PET data in list mode and monitoring of the patient's head movements with a motion tracking system. According to the measured head motion, the line of response (LOR) of each single detected PET event is spatially transformed, resulting in a spatially fully corrected data set. The basic algorithm for spatial transformation of LORs is based on a number of assumptions which can lead to spatial artifacts and quantitative inaccuracies in the resulting images. These deficiencies are discussed, demonstrated and methods for improvement are presented. Using different kinds of phantoms the validity and accuracy of the correction method is tested and its applicability to human studies is demonstrated as well.
引用
收藏
页码:1176 / 1185
页数:10
相关论文
共 50 条
  • [21] A METHOD FOR THE CORRECTION OF DRIFT IN MOVEMENT ANALYSIS
    STOKES, VP
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1991, 34 (04) : 275 - 281
  • [22] Fast Reconstruction for Deep Learning PET Head Motion Correction
    Zeng, Tianyi
    Zhang, Jiazhen
    Lieffrig, Eleonore V.
    Cai, Zhuotong
    Chen, Fuyao
    You, Chenyu
    Naganawa, Mika
    Lu, Yihuan
    Onofrey, John A.
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION, MICCAI 2023, PT X, 2023, 14229 : 710 - 719
  • [23] Motion correction of head movements in PET: Realisation for routine usage
    Tellmann, L
    Fulton, RR
    Bente, K
    Stangier, I
    Winz, O
    Just, U
    Herzog, H
    Pietrzyk, UK
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3105 - 3107
  • [24] PET Head-Motion Correction by facial feature tracking
    Goddard, James
    Mandelkern, Mark
    McClintick, Megan
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [25] The Effects of Complex Head Motion in PET/CT Attenuation Correction
    Lindsay, Clifford
    Mukherjee, Joyeeta M.
    Olivier, Patrick
    King, Michael A.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [26] Method for accurate registration of PET and MRI to histopathology of the prostate
    Piert, M. R.
    Siddiqui, J.
    Rogers, V.
    Montgomery, J.
    Davenport, M. S.
    Kunju, L. P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S390 - S390
  • [27] HEAD MOVEMENT IN NORMAL SUBJECTS DURING SIMULATED PET BRAIN IMAGING WITH AND WITHOUT HEAD RESTRAINT
    GREEN, MV
    SEIDEL, J
    STEIN, SD
    TEDDER, TE
    KEMPNER, KM
    KERTZMAN, C
    ZEFFIRO, TA
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (09) : 1538 - 1546
  • [28] Accurate Transmission-Less Attenuation Correction Method for Amyloid-β Brain PET Using Deep Neural Network
    Choi, Bo-Hye
    Hwang, Donghwi
    Kang, Seung-Kwan
    Kim, Kyeong-Yun
    Choi, Hongyoon
    Seo, Seongho
    Lee, Jae-Sung
    ELECTRONICS, 2021, 10 (15)
  • [29] FAST, ACCURATE METHOD OF MEASURING ANT HEAD WIDTHS
    PORTER, SD
    ANNALS OF THE ENTOMOLOGICAL SOCIETY OF AMERICA, 1983, 76 (05) : 866 - 867
  • [30] A fast and accurate method for registration of MR images of the head
    Kotsas, P
    Malasiotis, S
    Strintzis, M
    Piraino, DW
    Cornhill, JF
    INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 1998, 52 (1-3) : 167 - 182