An accurate method for correction of head movement in PET

被引:91
|
作者
Bühler, P
Just, U
Will, E
Kotzerke, J
van den Hoff, J
机构
[1] Tech Univ Dresden, Dept Nucl Med, D-01328 Dresden, Germany
[2] PET Ctr Rossendorf, D-01314 Dresden, Germany
关键词
motion compensation; motion measurement; positron emission tomography;
D O I
10.1109/TMI.2004.831214
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A method is presented to correct positron emission tomography (PET) data for head motion during data acquisition. The method is based on simultaneous acquisition of PET data in list mode and monitoring of the patient's head movements with a motion tracking system. According to the measured head motion, the line of response (LOR) of each single detected PET event is spatially transformed, resulting in a spatially fully corrected data set. The basic algorithm for spatial transformation of LORs is based on a number of assumptions which can lead to spatial artifacts and quantitative inaccuracies in the resulting images. These deficiencies are discussed, demonstrated and methods for improvement are presented. Using different kinds of phantoms the validity and accuracy of the correction method is tested and its applicability to human studies is demonstrated as well.
引用
收藏
页码:1176 / 1185
页数:10
相关论文
共 50 条
  • [1] Correction of head movement in PET studies: a comparison of methods
    Montgomery, A
    Mehta, M
    Turkheimer, F
    Thielemans, K
    Mustafovic, S
    Grasby, P
    NEUROIMAGE, 2004, 22 : T190 - T191
  • [2] Correction of head movement on PET studies: Comparison of methods
    Montgomery, Andrew J.
    Thielemans, Kris
    Mehta, Mitul A.
    Turkbeimer, Federico
    Mustafovic, Sanida
    Girasby, Paul M.
    JOURNAL OF NUCLEAR MEDICINE, 2006, 47 (12) : 1936 - 1944
  • [3] ACCURATE ATTENUATION CORRECTION DESPITE MOVEMENT DURING PET IMAGING
    ANDERSSON, JLR
    VAGNHAMMAR, BE
    SCHNEIDER, H
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (04) : 670 - 678
  • [4] A Sparse Transmission Method for PET Attenuation Correction in the Head
    Watson, Charles C.
    Panin, Vladimir Y.
    Keller, Sune H.
    Holm, Soren
    Nuyts, Johan
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [5] An Accurate PET Time Calibration Method With Phantom Position Correction
    Lu, Xinyu
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [6] A quality controlled method for movement correction in dynamic PET.
    Votaw, JR
    Faber, TL
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 200P - 201P
  • [7] Accurate attenuation correction in PET without accurate transmission measurements
    Welch, A
    Campbell, C
    Clackdoyle, R
    Natterer, F
    Mikecz, P
    Chillcot, F
    Dodd, M
    Hopwood, P
    Craib, S
    Gullberg, GT
    Sharp, P
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1697 - 1701
  • [8] Compensation for head movement in 3D PET
    Fulton, RR
    Tellmann, L
    Pietrzyk, U
    Herzog, H
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 2013 - 2017
  • [9] Correction of motion tracking errors for PET head rigid motion correction
    Miranda, Alan
    Kroll, Tina
    Schweda, Vanessa
    Staelens, Steven
    Verhaeghe, Jeroen
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (17):
  • [10] Evaluation of an attenuation correction method for PET/MR imaging of the head based on substitute CT images
    Anne Larsson
    Adam Johansson
    Jan Axelsson
    Tufve Nyholm
    Thomas Asklund
    Katrine Riklund
    Mikael Karlsson
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2013, 26 : 127 - 136