Amperometric determination of hydrogen peroxide with a manganese dioxide-modified carbon paste electrode using flow injection analysis

被引:109
|
作者
Schachl, K
Alemu, H
Kalcher, K
Jezkova, J
Svancara, I
Vytras, K
机构
[1] KARL FRANZENS UNIV GRAZ,INST ANALYT CHEM,A-8010 GRAZ,AUSTRIA
[2] UNIV ADDIS ABABA,DEPT CHEM,ADDIS ABABA,ETHIOPIA
[3] UNIV PARDUBICE,DEPT ANALYT CHEM,CZ-53210 PARDUBICE,CZECH REPUBLIC
关键词
manganese dioxide; hydrogen peroxide; flow injection analysis; amperometry; modified carbon paste electrode;
D O I
10.1039/a701723e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A carbon paste electrode bulk modified with MnO2 was investigated as an amperometric detector for hydrogen peroxide in flow injection analysis (FIA). With an operating potential of +0.46 V versus Ag/AgCl, H2O2 produces catalytic oxidation currents which can be exploited for quantitative determinations. Factors influencing the analytical performance of the electrode, such as paste composition and pH, were studied both for batch voltammetry and for FIA. For the flow system the influence of the injection volume and flow rate were examined. The amperometric signals are linearly proportional to H2O2 concentrations in the range 0.5-350 mg l(-1), showing a detection limit (three times the signal-to-noise ratio) of 45 mu g l(-1).
引用
收藏
页码:985 / 989
页数:5
相关论文
共 50 条
  • [31] AMPEROMETRIC DETERMINATION OF DOPAMINE ON AN ENZYMATICALLY MODIFIED CARBON-PASTE ELECTRODE
    FORZANI, ES
    RIVAS, GA
    SOLIS, VM
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 382 (1-2): : 33 - 40
  • [32] A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxide
    An’amt Mohamed Noor
    Muhammad Mehmood Shahid
    Perumal Rameshkumar
    Nay Ming Huang
    Microchimica Acta, 2016, 183 : 911 - 916
  • [33] Modified carbon paste electrodes for flow injection amperometric determination of isocitrate dehydrogenase activity in serum
    Rodríguez-Granda, P
    Lobo-Castañón, MJ
    Miranda-Ordieres, AJ
    Tuñón-Blanco, P
    ANALYTICAL BIOCHEMISTRY, 2002, 308 (02) : 195 - 203
  • [34] Phosphomolybdate-polypyrrole composite bulk-modified carbon paste electrode for a hydrogen peroxide amperometric sensor
    Wang, XL
    Zhang, H
    Wang, EB
    Han, ZB
    Hu, CW
    MATERIALS LETTERS, 2004, 58 (10) : 1661 - 1664
  • [35] Flow injection-pulse amperometric detection of ephedrine at a cobalt phthalocyanine modified carbon paste electrode
    Cookeas, EG
    Efstathiou, CE
    ANALYST, 2000, 125 (06) : 1147 - 1150
  • [36] Differential amperometric determination of hydrogen peroxide in honeys using flow-injection analysis with enzymatic reactor
    de Abreu Franchini, Romulo Augusto
    Costa Matos, Maria Auxiliadora
    Colombara, Rosana
    Matos, Renato Camargo
    TALANTA, 2008, 75 (01) : 301 - 306
  • [37] Cost-effective flow injection amperometric system with metal nanoparticle loaded carbon nanotube modified screen printed carbon electrode for sensitive determination of hydrogen peroxide
    Reanpang, Preeyaporn
    Themsirimongkon, Suwaphid
    Saipanya, Surin
    Chailapakul, Orawon
    Jakmunee, Jaroon
    TALANTA, 2015, 144 : 868 - 874
  • [38] Amperometric biosensor for total monoamines using a glassy carbon paste electrode modified with human monoamine oxidase B and manganese dioxide particles
    Maximilian Aigner
    Dietlind Telsnig
    Kurt Kalcher
    Christian Teubl
    Peter Macheroux
    Silvia Wallner
    Dale Edmondson
    Astrid Ortner
    Microchimica Acta, 2015, 182 : 925 - 931
  • [39] Amperometric biosensor for total monoamines using a glassy carbon paste electrode modified with human monoamine oxidase B and manganese dioxide particles
    Aigner, Maximilian
    Telsnig, Dietlind
    Kalcher, Kurt
    Teubl, Christian
    Macheroux, Peter
    Wallner, Silvia
    Edmondson, Dale
    Ortner, Astrid
    MICROCHIMICA ACTA, 2015, 182 (5-6) : 925 - 931
  • [40] Electrochemical evaluation of the a carbon-paste electrode modified with spinel manganese(IV) oxide under flow conditions for amperometric determination of lithium
    Raymundo-Pereira, Paulo A.
    Martin, Cibely S.
    Bergamini, Marcio F.
    Bocchi, Nerilso
    Teixeira, Marcos F. S.
    ELECTROCHIMICA ACTA, 2011, 56 (05) : 2552 - 2558