AMPEROMETRIC DETERMINATION OF DOPAMINE ON AN ENZYMATICALLY MODIFIED CARBON-PASTE ELECTRODE

被引:89
|
作者
FORZANI, ES
RIVAS, GA
SOLIS, VM
机构
[1] INFIQC, Departamento de Físico Química, Facultad de Ciencias Químicas, 5016 Córdoba, Sucursal 16
来源
JOURNAL OF ELECTROANALYTICAL CHEMISTRY | 1995年 / 382卷 / 1-2期
关键词
AMPEROMETRY; ENZYME ELECTRODE; DOPAMINE; CARBON PASTE ELECTRODE;
D O I
10.1016/0022-0728(94)03640-O
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The amperometric determination of dopamine under controlled convective conditions on an enzymatically modified carbon paste electrode was studied using potato tissue as a source of polyphenol oxidase. Enzymatic kinetic constants and substrate diffusional-resistance parameters were determined and an analysis of the most common interferents was made. It is concluded that the electrode is suitable for the quantification of dopamine with a detection limit as low as 2.5 x 10(-6) M when the hydrodynamic conditions are carefully controlled. The electrode is active towards dopac, ascorbic acid and pyrocatechol but not L-tyrosine, L-dopa, homovanillic acid, adrenaline, normetanephrine and vanilmandelic acid.
引用
收藏
页码:33 / 40
页数:8
相关论文
共 50 条
  • [1] DETERMINATION OF PHENYLEPHRINE WITH A MODIFIED CARBON-PASTE ELECTRODE
    PERLADO, JC
    ZAPARDIEL, A
    BERMEJO, E
    PEREZ, JA
    HERNANDEZ, L
    [J]. ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) : 83 - 90
  • [2] VOLTAMMETRIC DETERMINATION OF NITRATE WITH A MODIFIED CARBON-PASTE ELECTRODE
    NEUHOLD, C
    KALCHER, K
    DIEWALD, W
    CAI, XH
    RABER, G
    [J]. ELECTROANALYSIS, 1994, 6 (03) : 227 - 236
  • [3] ELECTROCATALYTIC AMPEROMETRIC DETECTION OF HYDROXYLAMINE WITH A PALLADIUM-MODIFIED CARBON-PASTE ELECTRODE
    CAI, XH
    KALCHER, K
    LINTSCHINGER, J
    NEUHOLD, CG
    TYKARSKI, J
    OGOREVC, B
    [J]. ELECTROANALYSIS, 1995, 7 (06) : 556 - 559
  • [4] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF THIOCYANATE AND SELENOCYANATE AT A COBALT PHTHALOCYANINE MODIFIED CARBON-PASTE ELECTRODE
    COOKEAS, EG
    EFSTATHIOU, CE
    [J]. ANALYST, 1994, 119 (07) : 1607 - 1612
  • [5] MODIFIED CARBON-PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF TRACE SILICON
    GURENTSOVA, OI
    PROKHOROVA, GV
    OSIPOVA, EA
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 47 (09) : 1224 - 1228
  • [6] VOLTAMMETRIC DETERMINATION OF LINURON AT A CARBON-PASTE ELECTRODE MODIFIED WITH SEPIOLITE
    HERNANDEZ, P
    VICENTE, J
    GONZALEZ, M
    HERNANDEZ, L
    [J]. TALANTA, 1990, 37 (08) : 789 - 794
  • [7] FLOW-INJECTION AMPEROMETRIC DETECTION OF ANILINE WITH A PEROXIDASE MODIFIED CARBON-PASTE ELECTRODE
    DOMINGUEZSANCHEZ, P
    OSULLIVAN, CK
    MIRANDAORDIERES, AJ
    TUNONBLANCO, P
    SMYTH, MR
    [J]. ANALYTICA CHIMICA ACTA, 1994, 291 (03) : 349 - 356
  • [8] MIXED FERROCENE GLUCOSE-OXIDASE CARBON-PASTE ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE
    WANG, J
    WU, LH
    LU, ZL
    LI, RL
    SANCHEZ, J
    [J]. ANALYTICA CHIMICA ACTA, 1990, 228 (02) : 251 - 257
  • [9] SELECTIVE DETERMINATION OF PYRIDOXAL WITH AN OCTADECYLAMINE-MODIFIED CARBON-PASTE ELECTRODE
    EGASHIRA, N
    ARAGAKI, S
    IWANAGA, H
    OHGA, K
    [J]. ANALYTICAL SCIENCES, 1991, 7 (05) : 691 - 694
  • [10] ON DETERMINATION OF MANGANESE AND LEAD AT CARBON-PASTE ELECTRODE
    MONIEN, H
    ZINKE, K
    [J]. ZEITSCHRIFT FUR ANALYTISCHE CHEMIE FRESENIUS, 1968, 240 (01): : 32 - &