Use of motor current in flow rate measurement for the magnetically suspended centrifugal blood pump

被引:0
|
作者
Tsukiya, T
Akamatsu, T
Nishimura, K
Yamada, T
Nakazeki, T
机构
[1] KYOTO UNIV,DEPT CARDIOVASC SURG,KYOTO,JAPAN
[2] NTN CORP,IWATA,JAPAN
关键词
ventricular assist device; rotary blood pump; magnetic suspension; indirect flow rate measurement; viscosity;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Indirect measurement of the flow rate of a centrifugal blood pump using the driving motor current was studied. The pump flow rate can be expressed as a function of the motor current under a given motor speed in the absence of energy loss resulting from uncertain mechanical contact friction. The magnetically suspended centrifugal blood pump (MSCP), developed by the collaboration of Kyoto University and NTN Inc., was suitable for the application of this measuring method because the impeller is suspended magnetically inside the pump housing without any mechanical contact. The effect of fluid viscosity on the pump performance was investigated in detail, and it was possible to estimate the pump flow rate and the pressure difference through the pump (from inlet port to outlet port) accurately by monitoring the motor current and speed when the kinematic viscosity of working fluids was known. The kinematic viscosity of working fluids can also be measured with the MSCP. The motor current and motor speed were monitored in a chronic animal experiment, and the estimated flow rate and pressure difference showed good correlation with directly measured data.
引用
收藏
页码:396 / 401
页数:6
相关论文
共 50 条
  • [31] A new magnetically suspended centrifugal pump: In vitro and preliminary in vivo assessment
    Park, CH
    Nishimura, K
    Akamatsu, T
    Tsukiya, T
    Matsuda, K
    Ban, T
    ARTIFICIAL ORGANS, 1996, 20 (02) : 128 - 131
  • [32] A Passive Magnetically and Hydrodynamically Suspended Rotary Blood Pump
    Stoiber, Martin
    Grasl, Christian
    Pirker, Stefan
    Raderer, Franz
    Schistek, Roland
    Huber, Leopold
    Gittler, Philipp
    Schima, Heinrich
    ARTIFICIAL ORGANS, 2009, 33 (03) : 250 - 257
  • [33] VentrAssist hydrodynamically suspended, open, centrifugal blood pump
    Watterson, PA
    Woodard, JC
    Ramsden, VS
    Reizes, JA
    ARTIFICIAL ORGANS, 2000, 24 (06) : 475 - 477
  • [34] Results of chronic animal experiments with a new version of a magnetically suspended centrifugal pump
    Nishimura, Kazunobu
    Kono, Satoshi
    Nishina, Takeshi
    Akamatsu, Teruaki
    Tsukiya, Tomonori
    Nojiri, Chisato
    Ozaki, Takayoshi
    Komeda, Masashi
    ASAIO Journal, 44 (05):
  • [35] Results of chronic animal experiments with a new version of a magnetically suspended centrifugal pump
    Nishimura, K
    Kono, S
    Nishina, T
    Akamatsu, T
    Tsukiya, T
    Nojiri, C
    Ozaki, T
    Komeda, M
    ASAIO JOURNAL, 1998, 44 (05) : M725 - M727
  • [36] Dynamic characteristics of a magnetically levitated impeller in a centrifugal blood pump
    Asama, Junichi
    Shinshi, Tadahiko
    Hoshi, Hideo
    Takatani, Setsuo
    Shimokohbe, Akira
    ARTIFICIAL ORGANS, 2007, 31 (04) : 301 - 311
  • [37] Noninvasive pump flow estimation of a centrifugal blood pump
    Wakisaka, Y
    Okuzono, Y
    Taenaka, Y
    Chikanari, K
    Masuzawa, T
    Nakatani, T
    Tatsumi, E
    Nishimura, T
    Takewa, Y
    Ohno, T
    Takano, H
    ARTIFICIAL ORGANS, 1997, 21 (07) : 651 - 654
  • [38] A Method for Indirect Measurement of the Flow Rate of an Electrically Driven Centrifugal Pump Installation
    Solodkiy E.M.
    Petrochenkov A.B.
    Vishnyakov D.D.
    Salnikov S.V.
    Solodkiy, E.M. (journal-elektrotechnika@mail.ru), 1600, Pleiades journals (92): : 663 - 667
  • [39] Estimation of changes in dynamic hydraulic force in a magnetically suspended centrifugal blood pump with transient computational fluid dynamics analysis
    Masuzawa, Toru
    Ohta, Akiko
    Tanaka, Nobuatu
    Qian, Yi
    Tsukiya, Tomonori
    JOURNAL OF ARTIFICIAL ORGANS, 2009, 12 (03) : 150 - 159
  • [40] Estimation of changes in dynamic hydraulic force in a magnetically suspended centrifugal blood pump with transient computational fluid dynamics analysis
    Toru Masuzawa
    Akiko Ohta
    Nobuatu Tanaka
    Yi Qian
    Tomonori Tsukiya
    Journal of Artificial Organs, 2009, 12 : 150 - 159