Evaluation of the Blinq Vision Screener in the Detection of Amblyopia and Strabismus in Children

被引:5
|
作者
Devlieger, Arnaud [1 ]
Youssfi, Abdelhakim [1 ]
Cordonnier, Monique [1 ]
机构
[1] Univ Libre Bruxelles, Erasmus Hosp, Dept Ophthalmol, Brussels, Belgium
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2022年 / 11卷 / 04期
关键词
pediatric; strabismus; amblyopia; prevention; PREVALENCE; ACCURACY; AGE;
D O I
10.1167/tvst.11.4.10
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Amblyopia is a major health problem with an estimated 2% to 4% of the population affected. Screening combined with corrective measures, such as correction of refractive error and occlusion of the dominant eye, could reduce this prevalence. A new pediatric vision scanner, the blinq (Rebion, Boston, MA), studies the foveolar quality of fixation of each eye during binocular viewing. Based on the initial premise that poor quality foveolar or non-foveolar fixation is indicative of strabismus and, potentially of amblyopia, this study evaluates the effectiveness of the blinq screening device in detecting these two conditions compared to a standard ophthalmic examination (Gold Standard) based on the recommendations of the American Association for Pediatric Ophthalmology and Strabismus. Material and Methods: A prospective study was performed on a total of 101 children between 2 and 8 years of age. These children were offered a test by the blinq screening device before a standard ophthalmological examination in the ophthalmology department of the Erasmus Hospital in Brussels, Belgium. The two tests were then compared. Results: In a pediatric population heightened with amblyopia and strabismus (prevalence of 33.4%) and based on the Gold Standard Examination, the blinq device showed a specificity of 73.1% (95% confidence interval [CI] = 60.9%-83.2%) with a sensitivity of 91.2% (95% CI = 76.3%-98.1) to detect these conditions. The positive and negative predictive values were 63.3% (95% CI = 53.4%-72.2%) and 94.2% (95% CI = 84.6%-98%) respectively. The positive likelihood ratio (LR+) was 3.39 (95% CI = 2.26-5.11) for a negative likelihood ratio of 0.12 (95% CI = 0.04-0.36). Conclusions: The blinq device has good sensitivity, but insufficient specificity to be used alone in the first line of screening. Whereas other devices on the market detect risk factors that may lead to amblyopia, the blinq pediatric vision scanner detects poor foveolar fixation and strabismus, giving it a potential advantage in sensitivity to directly detect strabismus, including microstrabismus. The blinq does not detect refractive abnormalities, however, and will therefore need to be improved in the future to be used alone in pediatric vision screening. Translational Relevance: The blinq device detects visual axis alignment abnormalities with potential impact in the early detection of strabismus and subsequent associated amblyopia.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] ACUPUNCTURE AND ITS CLINICAL EFFECT IN CHILDREN WITH STRABISMUS AND AMBLYOPIA
    KOVALEVSKY, EI
    DUBOVSKAYA, LA
    GUBAREVA, RA
    LAZAREVA, LA
    VESTNIK OFTALMOLOGII, 1984, (01) : 28 - 31
  • [42] Eye-hand coordination in children with amblyopia and strabismus
    Niechwiej-Szwedo, Ewa
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [43] PRESCHOOL VISION SCREENING FOR AMBLYOPIA AND STRABISMUS - PROGRAMS, METHODS, GUIDELINES, 1983
    EHRLICH, MI
    REINECKE, RD
    SIMONS, K
    SURVEY OF OPHTHALMOLOGY, 1983, 28 (03) : 145 - 163
  • [44] An Evaluation of the Amblyopia and Strabismus Questionnaire Using Rasch Analysis
    Vianya-Estopa, Marta
    Elliott, David B.
    Barrett, Brendan T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (05) : 2496 - 2503
  • [45] Evaluation of the Spot Vision Screener for children with limited access to ocular health care
    Barugel, Raphael
    Touhami, Sara
    Samama, Sacha
    Landre, Celine
    Busquet, Gauthier
    Vera, Liza
    Quoc, Emmanuel Bui
    JOURNAL OF AAPOS, 2019, 23 (03): : 153 - 155
  • [46] Effectiveness of the iPhone GoCheck Kids smartphone vision screener in detecting amblyopia risk factors
    Walker, Mollianna
    Duvall, Alba
    Daniels, Mackenzie
    Doan, Mailynh
    Edmondson, Luke E.
    Cheeseman, Edward W.
    Wilson, M. Edward
    Trivedi, Rupal H.
    Peterseim, Mae Millicent W.
    JOURNAL OF AAPOS, 2020, 24 (01): : 16.e1 - 16.e5
  • [47] OCCLUSION THERAPY OF JAPANESE CHILDREN WITH ANISOMETROPIC AMBLYOPIA WITHOUT STRABISMUS
    NODA, S
    HAYASAKA, S
    SETOGAWA, T
    ANNALS OF OPHTHALMOLOGY, 1993, 25 (04): : 145 - 147
  • [48] Risk Factors for Amblyopia and Strabismus in Young Singapore Chinese Children
    Chia, A.
    Lin, X.
    Gazzard, G.
    Quah, B.
    Ling, Y.
    Chang, B. C.
    Young, T. L.
    Wong, T. Y.
    Saw, S-M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [49] Study on the impact of refractive anisometropia on strabismus, stereopsis, and amblyopia in children
    Qiao, Shanli
    Chen, Jing
    Zhang, Jianfei
    Sun, Changfeng
    MEDICINE, 2024, 103 (44)
  • [50] CLINICAL EFFECT OF COMPUTER USE IN THE TREATMENT OF CHILDREN WITH STRABISMUS AND AMBLYOPIA
    TATARINOV, SA
    AMELYANOVA, SG
    KASCHENKO, TP
    LAKOMKIN, VI
    AVUCHENKOVA, TN
    GALICH, VI
    VESTNIK OFTALMOLOGII, 1993, 109 (05) : 28 - 29