Evaluation of the Blinq Vision Screener in the Detection of Amblyopia and Strabismus in Children

被引:5
|
作者
Devlieger, Arnaud [1 ]
Youssfi, Abdelhakim [1 ]
Cordonnier, Monique [1 ]
机构
[1] Univ Libre Bruxelles, Erasmus Hosp, Dept Ophthalmol, Brussels, Belgium
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2022年 / 11卷 / 04期
关键词
pediatric; strabismus; amblyopia; prevention; PREVALENCE; ACCURACY; AGE;
D O I
10.1167/tvst.11.4.10
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Amblyopia is a major health problem with an estimated 2% to 4% of the population affected. Screening combined with corrective measures, such as correction of refractive error and occlusion of the dominant eye, could reduce this prevalence. A new pediatric vision scanner, the blinq (Rebion, Boston, MA), studies the foveolar quality of fixation of each eye during binocular viewing. Based on the initial premise that poor quality foveolar or non-foveolar fixation is indicative of strabismus and, potentially of amblyopia, this study evaluates the effectiveness of the blinq screening device in detecting these two conditions compared to a standard ophthalmic examination (Gold Standard) based on the recommendations of the American Association for Pediatric Ophthalmology and Strabismus. Material and Methods: A prospective study was performed on a total of 101 children between 2 and 8 years of age. These children were offered a test by the blinq screening device before a standard ophthalmological examination in the ophthalmology department of the Erasmus Hospital in Brussels, Belgium. The two tests were then compared. Results: In a pediatric population heightened with amblyopia and strabismus (prevalence of 33.4%) and based on the Gold Standard Examination, the blinq device showed a specificity of 73.1% (95% confidence interval [CI] = 60.9%-83.2%) with a sensitivity of 91.2% (95% CI = 76.3%-98.1) to detect these conditions. The positive and negative predictive values were 63.3% (95% CI = 53.4%-72.2%) and 94.2% (95% CI = 84.6%-98%) respectively. The positive likelihood ratio (LR+) was 3.39 (95% CI = 2.26-5.11) for a negative likelihood ratio of 0.12 (95% CI = 0.04-0.36). Conclusions: The blinq device has good sensitivity, but insufficient specificity to be used alone in the first line of screening. Whereas other devices on the market detect risk factors that may lead to amblyopia, the blinq pediatric vision scanner detects poor foveolar fixation and strabismus, giving it a potential advantage in sensitivity to directly detect strabismus, including microstrabismus. The blinq does not detect refractive abnormalities, however, and will therefore need to be improved in the future to be used alone in pediatric vision screening. Translational Relevance: The blinq device detects visual axis alignment abnormalities with potential impact in the early detection of strabismus and subsequent associated amblyopia.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Testability of Vision and Refraction in Preschoolers: The Strabismus, Amblyopia, and Refractive Error Study in Singaporean Children
    Trager, Michelle J.
    Dirani, Mohamed
    Fan, Qiao
    Gazzard, Gus
    Selvaraj, Prabakaran
    Chia, Audrey
    Wong, Tien-Yin
    Young, Terri L.
    Varma, Rohit
    Saw, Seang-Mei
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 148 (02) : 235 - 241
  • [22] The effectiveness of the Spot Vision Screener in detecting amblyopia risk factors
    Peterseim, Mae Millicent W.
    Papa, Carrie E.
    Wilson, M. Edward
    Davidson, Jennifer D.
    Shtessel, Maria
    Husain, Mavesh
    Cheeseman, Edward W.
    Wolf, Bethany J.
    Trivedi, Rupal
    JOURNAL OF AAPOS, 2014, 18 (06): : 539 - 542
  • [23] New model for the evaluation and management of strabismus, amblyopia and refractive errors in children
    Schalit, G
    Howell, J
    Tansley, S
    Adams, GGW
    McIntyre, A
    TRANSACTIONS OF THE IX INTERNATIONAL ORTHOPTIC CONGRESS, 1999, : 357 - 357
  • [24] Rapid, High-Accuracy Detection of Strabismus and Amblyopia Using the Pediatric Vision Scanner
    Loudon, Sjoukje E.
    Rook, Caitlin A.
    Nassif, Deborah S.
    Piskun, Nadya V.
    Hunter, David G.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (08) : 5043 - 5048
  • [25] The Jerusalem Early Detection of Amblyopia and Strabismus Study: Effectiveness of screening tests for early detection of amblyopia and strabismus.
    Karpati, T
    Abramson, JH
    Paiti, H
    Hirsch, I
    Neumark, Y
    Mazover, A
    Kaiserman, I
    Farber, M
    Pe'er, J
    Yanko, L
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S382 - S382
  • [26] DETECTION OF AMBLYOPIA AND DEVELOPMENT OF BINOCULAR VISION IN INFANTS AND CHILDREN
    GWIAZDA, JE
    CURRENT OPINION IN OPHTHALMOLOGY, 1992, 3 (06) : 735 - 740
  • [27] Evaluation of the Spot Vision Screener in young children in Costa Rica
    Arana Mendez, Maricela
    Arguello, Leslie
    Martinez, Joaquin
    Salas Vargas, Marisela
    Alvarado Rodriguez, Ana Maria
    Papa, Carrie E.
    Peterseim, Carolyn M.
    Otarola Viquez, Mauricio
    Trivedi, Rupal H.
    Peterseim, Mae Millicent W.
    JOURNAL OF AAPOS, 2015, 19 (05): : 441 - 444
  • [28] Evaluation of the Spot Vision Screener in School-Aged Children
    Peterseim, Mae Millicent W.
    Trivedi, Rupal H.
    Feldman, Samuel
    Husain, Mahvash
    Walker, Mollianna
    Wilson, M. Edward
    Wolf, Bethany J.
    JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2020, 57 (03) : 146 - 153
  • [29] Comparative AAPOS Validation of the Birefringent Amblyopia Screener with Isolated Small-Angle Strabismus
    Arnold, Robert W.
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 325 - 329
  • [30] Effectiveness of the Spot Vision Screener in screening 3-year-old children with potential amblyopia in Japan
    Hayashi, Shion
    Suzuki, Issaku
    Inamura, Akira
    Iino, Yaoko
    Nishitsuka, Koichi
    Nishina, Sachiko
    Yamashita, Hidetoshi
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2021, 65 (04) : 537 - 545