Evaluation of the Blinq Vision Screener in the Detection of Amblyopia and Strabismus in Children

被引:5
|
作者
Devlieger, Arnaud [1 ]
Youssfi, Abdelhakim [1 ]
Cordonnier, Monique [1 ]
机构
[1] Univ Libre Bruxelles, Erasmus Hosp, Dept Ophthalmol, Brussels, Belgium
来源
关键词
pediatric; strabismus; amblyopia; prevention; PREVALENCE; ACCURACY; AGE;
D O I
10.1167/tvst.11.4.10
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Amblyopia is a major health problem with an estimated 2% to 4% of the population affected. Screening combined with corrective measures, such as correction of refractive error and occlusion of the dominant eye, could reduce this prevalence. A new pediatric vision scanner, the blinq (Rebion, Boston, MA), studies the foveolar quality of fixation of each eye during binocular viewing. Based on the initial premise that poor quality foveolar or non-foveolar fixation is indicative of strabismus and, potentially of amblyopia, this study evaluates the effectiveness of the blinq screening device in detecting these two conditions compared to a standard ophthalmic examination (Gold Standard) based on the recommendations of the American Association for Pediatric Ophthalmology and Strabismus. Material and Methods: A prospective study was performed on a total of 101 children between 2 and 8 years of age. These children were offered a test by the blinq screening device before a standard ophthalmological examination in the ophthalmology department of the Erasmus Hospital in Brussels, Belgium. The two tests were then compared. Results: In a pediatric population heightened with amblyopia and strabismus (prevalence of 33.4%) and based on the Gold Standard Examination, the blinq device showed a specificity of 73.1% (95% confidence interval [CI] = 60.9%-83.2%) with a sensitivity of 91.2% (95% CI = 76.3%-98.1) to detect these conditions. The positive and negative predictive values were 63.3% (95% CI = 53.4%-72.2%) and 94.2% (95% CI = 84.6%-98%) respectively. The positive likelihood ratio (LR+) was 3.39 (95% CI = 2.26-5.11) for a negative likelihood ratio of 0.12 (95% CI = 0.04-0.36). Conclusions: The blinq device has good sensitivity, but insufficient specificity to be used alone in the first line of screening. Whereas other devices on the market detect risk factors that may lead to amblyopia, the blinq pediatric vision scanner detects poor foveolar fixation and strabismus, giving it a potential advantage in sensitivity to directly detect strabismus, including microstrabismus. The blinq does not detect refractive abnormalities, however, and will therefore need to be improved in the future to be used alone in pediatric vision screening. Translational Relevance: The blinq device detects visual axis alignment abnormalities with potential impact in the early detection of strabismus and subsequent associated amblyopia.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Comment on "The blinq™ Vision Screener in Detection of Amblyopia and Strabismus"
    Hunter, David G.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 253 : 255 - 255
  • [2] Evaluation of the blinq vision scanner for detection of amblyopia and strabismus
    Bosque, Lorenzo E.
    Yamarino, Cailyn R.
    Salcedo, Natalia
    Schneier, Andrew J.
    Gold, Robert S.
    Blumenfeld, Louis C.
    Hunter, David G.
    JOURNAL OF AAPOS, 2021, 25 (04): : 214.e1 - 214.e7
  • [3] The blinqTM Vision Screener in Detection of Amblyopia and Strabismus
    Monahan, Savannah Reaves
    Smith, Samantha M.
    Gammeltoft, Elizabeth Thompson
    Trivedi, Rupal H.
    Wilson, Edward
    Bowsher, James D.
    Peterseim, Mae Millicent W.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 250 : 20 - 24
  • [4] The Pediatric Vision Screener III - Detection of strabismus in children
    Nassif, DS
    Piskun, NV
    Hunter, DG
    ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (04) : 509 - 513
  • [5] Detection of strabismus by the Spot Vision Screener
    Peterseim, Mae Millicent W.
    Davidson, Jennifer D.
    Trivedi, Rupal
    Wilson, M. Edward
    Papa, Carrie E.
    Cheeseman, Edward W.
    JOURNAL OF AAPOS, 2015, 19 (06): : 512 - 514
  • [6] Performance of the Plusoptix vision screener for the detection of amblyopia risk factors in children
    Matta, Noelle S.
    Singman, Eric L.
    Silbert, David I.
    JOURNAL OF AAPOS, 2008, 12 (05): : 490 - 492
  • [7] Performance of the Spot vision screener for the detection of amblyopia risk factors in children
    Silbert, David I.
    Matta, Noelle S.
    JOURNAL OF AAPOS, 2014, 18 (02): : 169 - 172
  • [8] Comparative AAPOS Validation of the blinq. Birefringent Amblyopia Screener with Isolated Small-Angle Strabismus [Response to Letter]
    Arnold, Robert W.
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 2775 - 2776
  • [9] Validation of the Birefringent Amblyopia Screener (Retinal Polarization Scanner), the Rebion Blinq.™
    Hunter, David G.
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 2599 - 2600
  • [10] Assessment of the OPTEC vision screener in the detection of amblyopia in the pediatric population
    Haschke, Mary
    Kinberg, Hannah
    Suh, Donny W.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)