Short communication: Thermal performance of a cryogenic helium pulsating heat pipe with three evaporator sections

被引:16
|
作者
Fonseca, Luis Diego [1 ]
Pfotenhauer, John [1 ]
Miller, Franklin [1 ]
机构
[1] Univ Wisconsin, Madison, WI 53706 USA
关键词
Pulsating Heat Pipe (PHP); Heat transfer; Helium;
D O I
10.1016/j.ijheatmasstransfer.2018.03.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
This short communication reports surprising results from on-going measurements of a helium pulsating heat pipe (PHP) in which the adiabatic length has been increased from 0.3 m to 1 m. In addition, the PHP has been constructed with a total of three evaporator sections. The PHP contains 42 parallel stainless steel tubes with an outer and inner diameter of 0.8 mm and 0.5 mm, respectively. PHPs with this configuration can serve as thermal spreaders for cryocoolers and can be used to cool multiple hot spots. Results and configuration details of the PHP with a 300 mm long adiabatic section have been previously published (Fonseca et al., 2017, 2018). The same PHP, now modified with a 1-meter long adiabatic section has been tested at the same heat load and fill ratio values as the 0.3 m PHP. The PHP operates between 3 K and 5.2 K using a Sumitomo cryocooler model RDK-408A2 with a cooling capacity of 1 W at 4.2 K. Interestingly, the results show that the temperature difference (T) between the evaporator and condenser sections of the PHP with the 1-m adiabatic section length is almost identical to that measured with the 0.3 m adiabatic section length PHP when the two different configurations are each operated at their respective optimum fill ratio. Temperature differences below 1 K are achieved when the heat load is less than 0.26 W per evaporator section (0.78 W total). Very similar optimal thermal conductance (Q/Delta T) values are obtained for both configurations, where a maximum thermal conductance of 0.383 W/K at a fill ratio of 58% and 0.387 W/K at a fill ratio of 70% are achieved for the 1 m and 0.3 m PHP, respectively. In addition, the optimal thermal performance can be expressed as an effective thermal conductivity that is proportional to the adiabatic length, resulting in a higher value for the 1-m PHP of 150 kW/m-K; while the 0.3 m PHP achieved a maximum thermal conductivity of almost 53 kW/m-K. This paper will present results based on equal heat load distribution throughout the evaporator sections. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:655 / 656
页数:2
相关论文
共 50 条
  • [31] Thermal performance of Pulsating Heat Pipe on Electric Motor as Cooling Application
    Aprianingsih, Nurhalimah
    Winarta, Adi
    Ariantara, Bambang
    Putra, Nandy
    3RD INTERNATIONAL TROPICAL RENEWABLE ENERGY CONFERENCE SUSTAINABLE DEVELOPMENT OF TROPICAL RENEWABLE ENERGY (I-TREC 2018), 2018, 67
  • [32] Effect of nanofluids on thermal performance of closed loop pulsating heat pipe
    Karthikeyan, V. K.
    Ramachandran, K.
    Pillai, B. C.
    Solomon, A. Brusly
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2014, 54 : 171 - 178
  • [33] EXPERIMENTAL INVESTIGATIONS ON THERMAL PERFORMANCE OF A CLOSED LOOP PULSATING HEAT PIPE
    Wang, Yu
    Li, Weiyi
    Wei, Lianyou
    Cao, Binbin
    PROCEEDINGS OF THE ASME MICRO/NANOSCALE HEAT AND MASS TRANSFER INTERNATIONAL CONFERENCE, VOL 3, 2010, : 295 - 303
  • [34] EXPERIMENTAL INVESTIGATION OF CIRCULATING MOTION ON THE THERMAL PERFORMANCE OF A PULSATING HEAT PIPE
    Kim, Wookyoung
    Kim, Sung Jin
    4TH THERMAL AND FLUIDS ENGINEERING CONFERENCE, ASTFE 2019, 2019,
  • [35] A comparative study of flow regimes and thermal performance between flat plate pulsating heat pipe and capillary tube pulsating heat pipe
    Takawale, Anand
    Abraham, Satyanand
    Sielaff, Axel
    Mahapatra, Pallab Sinha
    Pattamatta, Arvind
    Stephan, Peter
    APPLIED THERMAL ENGINEERING, 2019, 149 : 613 - 624
  • [36] Thermal performance of an open loop closed end pulsating heat pipe
    Saha, Manabendra
    Feroz, C. M.
    Ahmed, F.
    Mujib, T.
    HEAT AND MASS TRANSFER, 2012, 48 (02) : 259 - 265
  • [37] Effect of large redundant volume on the performance of multiple turns helium pulsating heat pipe
    Guo, Rendong
    Xu, Dong
    Shi, Yaran
    Huang, Chuanjun
    Li, Laifeng
    CRYOGENICS, 2023, 134
  • [38] Effect of filling ratio and orientation on the performance of a multiple turns helium pulsating heat pipe
    Li, Monan
    Li, Laifeng
    Xu, Dong
    CRYOGENICS, 2019, 100 : 62 - 68
  • [39] Modeling of cryogenic pulsating heat pipe using CFD techniques
    Opalski, Marcin
    Dixit, Tisha
    Baudouy, Bertrand
    Blasiak, Przemyslaw
    Ishimoto, Jun
    Pietrowicz, Slawomir
    CRYOGENICS, 2025, 147
  • [40] Effects of filling ratio of a long cryogenic Pulsating Heat Pipe
    Barba, Maria
    Bruce, Romain
    Bouchet, Florent
    Bonelli, Antoine
    Baudouy, Bertrand
    APPLIED THERMAL ENGINEERING, 2021, 194