Short communication: Thermal performance of a cryogenic helium pulsating heat pipe with three evaporator sections

被引:16
|
作者
Fonseca, Luis Diego [1 ]
Pfotenhauer, John [1 ]
Miller, Franklin [1 ]
机构
[1] Univ Wisconsin, Madison, WI 53706 USA
关键词
Pulsating Heat Pipe (PHP); Heat transfer; Helium;
D O I
10.1016/j.ijheatmasstransfer.2018.03.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
This short communication reports surprising results from on-going measurements of a helium pulsating heat pipe (PHP) in which the adiabatic length has been increased from 0.3 m to 1 m. In addition, the PHP has been constructed with a total of three evaporator sections. The PHP contains 42 parallel stainless steel tubes with an outer and inner diameter of 0.8 mm and 0.5 mm, respectively. PHPs with this configuration can serve as thermal spreaders for cryocoolers and can be used to cool multiple hot spots. Results and configuration details of the PHP with a 300 mm long adiabatic section have been previously published (Fonseca et al., 2017, 2018). The same PHP, now modified with a 1-meter long adiabatic section has been tested at the same heat load and fill ratio values as the 0.3 m PHP. The PHP operates between 3 K and 5.2 K using a Sumitomo cryocooler model RDK-408A2 with a cooling capacity of 1 W at 4.2 K. Interestingly, the results show that the temperature difference (T) between the evaporator and condenser sections of the PHP with the 1-m adiabatic section length is almost identical to that measured with the 0.3 m adiabatic section length PHP when the two different configurations are each operated at their respective optimum fill ratio. Temperature differences below 1 K are achieved when the heat load is less than 0.26 W per evaporator section (0.78 W total). Very similar optimal thermal conductance (Q/Delta T) values are obtained for both configurations, where a maximum thermal conductance of 0.383 W/K at a fill ratio of 58% and 0.387 W/K at a fill ratio of 70% are achieved for the 1 m and 0.3 m PHP, respectively. In addition, the optimal thermal performance can be expressed as an effective thermal conductivity that is proportional to the adiabatic length, resulting in a higher value for the 1-m PHP of 150 kW/m-K; while the 0.3 m PHP achieved a maximum thermal conductivity of almost 53 kW/m-K. This paper will present results based on equal heat load distribution throughout the evaporator sections. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:655 / 656
页数:2
相关论文
共 50 条
  • [21] Thermal Study of a one-meter long Neon Cryogenic Pulsating Heat Pipe
    Barba, M.
    Bruce, R.
    Bouchet, F.
    Bonelli, A.
    Baudouy, B.
    27TH INTERNATIONAL CRYOGENICS ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2018 (ICEC-ICMC 2018), 2019, 502
  • [22] EXPERIMENTAL STUDY OF EVAPORATOR SURFACE AREA INFLUENCE ON A CLOSED LOOP PULSATING HEAT PIPE PERFORMANCE
    Tabatabaee, Mohammad Hadi
    Mohammadi, Mahshid
    Shafii, Mohammad Behshad
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, VOL 2: FORA, 2012, : 233 - 238
  • [23] A Helium Based Pulsating Heat Pipe For Superconducting Magnets
    Fonseca, Luis Diego
    Miller, Franklin
    Pfotenhauer, John
    ADVANCES IN CRYOGENIC ENGINEERING, 2014, 1573 : 28 - 35
  • [24] Experimental Study on the Secondary Evaporator of a Cryogenic Loop Heat Pipe
    Zhao, Ya-nan
    Yan, Tao
    Li, Jian-guo
    Wang, Juan
    Liang, Jingtao
    ADVANCES IN CRYOGENIC ENGINEERING, 2014, 1573 : 20 - 27
  • [25] NUMERICAL INVESTIGATION OF THERMAL PERFORMANCE OF A CRYOGENIC OSCILLATING HEAT PIPE
    Liang, Qing
    Li, Yi
    Wang, Qiuliang
    HEAT TRANSFER RESEARCH, 2018, 49 (12) : 1171 - 1183
  • [26] Experimental Study of the Effects of Ferrofluid on Thermal Performance of a Pulsating Heat Pipe
    Maziar, Mohammadi
    Mohammad, Mohammadi
    Amir, R. Ghahremani
    Shafii, M. B.
    PROCEEDINGS IF THE ASME 9TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS AND MINICHANNELS 2011, VOL 1, 2012, : 435 - +
  • [27] Thermal performance of an open loop closed end pulsating heat pipe
    Manabendra Saha
    C. M. Feroz
    F. Ahmed
    T. Mujib
    Heat and Mass Transfer, 2012, 48 : 259 - 265
  • [28] Thermal performance of multiple pulsating cold end heat pipe radiator
    Xiahou G.
    Liu Y.
    Wang D.
    Liu H.
    Xiahou, Guowei (xh_gw@126.com), 1600, Central South University of Technology (48): : 533 - 539
  • [29] Thermal Performance Investigation by Infrared Analysis of Mini Pulsating Heat Pipe
    Bonfiglio, C.
    Bozzoli, F.
    Cattani, L.
    Iwata, N.
    Rainieri, S.
    Vocale, P.
    37TH UIT HEAT TRANSFER CONFERENCE, 2020, 1599
  • [30] Parametric Characterization on the Thermal Performance of a Closed Loop Pulsating Heat Pipe
    Rao, C. Sreenivasa
    Gupta, A.
    Narasimha, K. Rama
    JOURNAL OF APPLIED FLUID MECHANICS, 2016, 9 (02) : 615 - 624