A MIP-based flow-through fluoroimmunosensor as an alternative to immunosensors for the determination of digoxin in serum samples

被引:17
|
作者
Paniagua Gonzalez, Gema [1 ]
Fernandez Hernando, Pilar [1 ]
Durand Alegria, Jesus Senen [1 ]
机构
[1] Univ Nacl Educ Distancia, Fac Ciencias, Dept Ciencias Analit, E-28040 Madrid, Spain
关键词
Digoxin; Permanent immobilisation; Molecular imprinting; Flow-through fluorosensor; Serum analysis; ANTIBODIES;
D O I
10.1007/s00216-008-2584-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This work reports a comparative study of two automated flow-through fluorosensors for the determination of digoxin in serum samples: an immunosensor with an anti-digoxin polyclonal antibody as the reactive phase permanently immobilised on controlled-pore glass and a sensor with a selective reaction system based on a methacrylic molecularly imprinted polymer (MIP) synthesised by bulk polymerisation. The variables affecting the sensitivity and dynamic range of the sensors (e.g. the carrier and elution solutions, flow rates, pH and reagent concentrations) were optimized, and the binding characteristics of their reactive phases were compared in a competitive fluorescent assay. Digoxin was reproducibly determined by both sensors at the milligram per litre level (detection limit = 1.20 x 10(-3) mg L-1 and RSD = 4-7% for the immunosensor; detection limit = 1.7 x 10(-5) mg L-1 and RSD = 1-2% for the MIP sensor). No cross-reactivity with digoxin-related compounds was seen for either sensor at a digoxin/interferent ratio of 1:100. The lifetime of the immunosensor was about 50 immunoassays; its shelf life, when unused, is about 3 months. The lifetime of the MIP sensor was over 18 months. Both sensors were used to determine the digoxin concentration of human serum samples with satisfactory results.
引用
收藏
页码:963 / 970
页数:8
相关论文
共 50 条
  • [21] Determination of zinc (II) in pharmaceuticals based on a flow-through bulk optode
    Albero, MI
    Ortuño, JA
    García, MS
    Sánchez-Pedreño, C
    Expósito, R
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 29 (05) : 779 - 786
  • [22] A label-free flow-through immunosensor for determination of total- and free-PSA in human serum samples based on white-light reflectance spectroscopy
    Koukouvinos, G.
    Petrou, P. S.
    Misiakos, K.
    Drygiannakis, D.
    Raptis, I.
    Goustouridis, D.
    Kakabakos, S. E.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 209 : 1041 - 1048
  • [23] Kinetic methods for the determination of cadmium(II) based on a flow-through bulk optode
    Sanchez-Pedreño, C
    García, MS
    Ortuño, JA
    Albero, MI
    Expósito, R
    TALANTA, 2002, 56 (03) : 481 - 489
  • [24] Determination of antimony in soil samples by flow-through stripping chronopotentiometry with a microporous mercury-film electrode
    Manova, A.
    Strelec, M.
    Beinrohr, E.
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2007, 16 (04): : 607 - 611
  • [25] Determination of nickel in hair samples by graphite furnace atomic absorption spectrometry and flow-through stripping chronopotentiometry
    Borosova, Daniela
    Manova, Alena
    Mocak, Jan
    Beinrohr, Ernest
    ANALYTICAL METHODS, 2010, 2 (12) : 1913 - 1917
  • [26] Cadmium determination in natural water samples with an automatic multisyringe flow injection system coupled to a flow-through screen printed electrode
    Henriquez, C.
    Laglera, L. M.
    Alpizar, M. J.
    Calvo, J.
    Arduini, F.
    Cerda, V.
    TALANTA, 2012, 96 : 140 - 146
  • [27] FLUOROMETRIC-DETERMINATION OF ALKALINE-PHOSPHATASE ACTIVITY IN HUMAN SERUM BY USE OF A FLOW-THROUGH BIOSENSOR
    SANCHEZCABEZUDO, M
    FERNANDEZROMERO, JM
    DECASTRO, MDL
    JOURNAL OF BIOTECHNOLOGY, 1994, 37 (02) : 143 - 149
  • [28] A novel flow-through microdialysis separation unit with integrated differential potentiometric detection for the determination of chloride in soil samples
    Miró, M
    Frenzel, W
    ANALYST, 2003, 128 (10) : 1291 - 1297
  • [29] CONTINUOUS-FLOW SERUM-ALBUMIN DETERMINATION BY REACTION WITH PICRATE IONS, WITH USE OF A FLOW-THROUGH PICRATE ION ELECTRODE
    DIAMANDIS, EP
    PAPASTATHOPOULOS, DS
    HADJIIOANNOU, TP
    CLINICAL CHEMISTRY, 1981, 27 (03) : 427 - 430
  • [30] THE DETERMINATION OF ALKALINE-PHOSPHATASE ACTIVITY IN SERUM BY MEANS OF FLOW-THROUGH ANALYSIS WITH AN ION-SELECTIVE ELECTRODE
    HARA, T
    IMAKI, M
    TORIYAMA, M
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1981, 54 (05) : 1396 - 1399