A MIP-based flow-through fluoroimmunosensor as an alternative to immunosensors for the determination of digoxin in serum samples

被引:17
|
作者
Paniagua Gonzalez, Gema [1 ]
Fernandez Hernando, Pilar [1 ]
Durand Alegria, Jesus Senen [1 ]
机构
[1] Univ Nacl Educ Distancia, Fac Ciencias, Dept Ciencias Analit, E-28040 Madrid, Spain
关键词
Digoxin; Permanent immobilisation; Molecular imprinting; Flow-through fluorosensor; Serum analysis; ANTIBODIES;
D O I
10.1007/s00216-008-2584-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This work reports a comparative study of two automated flow-through fluorosensors for the determination of digoxin in serum samples: an immunosensor with an anti-digoxin polyclonal antibody as the reactive phase permanently immobilised on controlled-pore glass and a sensor with a selective reaction system based on a methacrylic molecularly imprinted polymer (MIP) synthesised by bulk polymerisation. The variables affecting the sensitivity and dynamic range of the sensors (e.g. the carrier and elution solutions, flow rates, pH and reagent concentrations) were optimized, and the binding characteristics of their reactive phases were compared in a competitive fluorescent assay. Digoxin was reproducibly determined by both sensors at the milligram per litre level (detection limit = 1.20 x 10(-3) mg L-1 and RSD = 4-7% for the immunosensor; detection limit = 1.7 x 10(-5) mg L-1 and RSD = 1-2% for the MIP sensor). No cross-reactivity with digoxin-related compounds was seen for either sensor at a digoxin/interferent ratio of 1:100. The lifetime of the immunosensor was about 50 immunoassays; its shelf life, when unused, is about 3 months. The lifetime of the MIP sensor was over 18 months. Both sensors were used to determine the digoxin concentration of human serum samples with satisfactory results.
引用
收藏
页码:963 / 970
页数:8
相关论文
共 50 条
  • [11] A FLOW-THROUGH DETECTOR FOR SIMULTANEOUS DETERMINATIONS OF GLUCOSE AND UREA IN SERUM SAMPLES
    MASCINI, M
    PALLESCHI, G
    ANALYTICA CHIMICA ACTA, 1983, 145 (JAN) : 213 - 217
  • [12] MIP-based extraction techniques for the determination of antibiotic residues in edible meat samples: Design, performance & recent developments
    Banan, Kamran
    Hatamabadi, Dara
    Afsharara, Hanif
    Mostafiz, Bahar
    Sadeghi, Hadise
    Rashidi, Soheil
    Beirami, Amirreza Dowlati
    Shahbazi, Mohammad-Ali
    Kecili, Rustem
    Hussain, Chaudhery Mustansar
    Ghorbani-Bidkorbeh, Fatemeh
    TRENDS IN FOOD SCIENCE & TECHNOLOGY, 2022, 119 : 164 - 178
  • [13] Determination of total sulphur dioxide in beer samples by flow-through chronopotentiometry
    Dvorak, Josef
    Dostalek, Pavel
    Sterba, Karel
    Cejka, Pavel
    Kellner, Vladimir
    Culik, Jiri
    Beinrohr, Ernest
    JOURNAL OF THE INSTITUTE OF BREWING, 2006, 112 (04) : 308 - 313
  • [14] DETERMINATION OF MANGANESE IN WATER SAMPLES BY GALVANOSTATIC STRIPPING CHRONOPOTENTIOMETRY IN A FLOW-THROUGH CELL
    BEINROHR, E
    CSEMI, P
    ROJAS, FJ
    HOFBAUEROVA, H
    ANALYST, 1994, 119 (06) : 1355 - 1359
  • [15] DEVELOPMENT OF AN OPTICAL FLOW-THROUGH BIOSENSOR FOR THE DETERMINATION OF SULFITE IN ENVIRONMENTAL-SAMPLES
    DECASTRO, MDL
    FERNANDEZROMERO, JM
    ANALYTICA CHIMICA ACTA, 1995, 311 (03) : 281 - 287
  • [16] Calibrationless determination of lead in waste water samples by flow-through stripping chronopotentiometry
    Strelec, M.
    Cacho, F.
    Manova, A.
    Hlubikova, S.
    Beinrohr, E.
    CHEMIA ANALITYCZNA, 2007, 52 (03): : 377 - 385
  • [17] Copper oxide based flow-through detector for glucose determination
    Matsubara, H
    Kondo, T
    Kanno, W
    Hodouchi, K
    Yamada, A
    ANALYTICA CHIMICA ACTA, 2000, 405 (1-2) : 87 - 92
  • [18] Contribution to Automation for Determination of Drugs Based on Flow-Through Optosensors
    Llorent-Martinez, E. J.
    Ortega-Barrales, P.
    Fernandez-De Cordova, M. L.
    Ruiz-Medina, A.
    APPLIED SPECTROSCOPY REVIEWS, 2011, 46 (05) : 339 - 367
  • [19] Determination of carbaryl in natural water samples by a surface plasmon resonance flow-through immunosensor
    Mauriz, E
    Calle, A
    Abad, A
    Montoya, A
    Hildebrandt, A
    Barceló, D
    Lechuga, LM
    BIOSENSORS & BIOELECTRONICS, 2006, 21 (11): : 2129 - 2136
  • [20] An optical sensor for the determination of digoxin in serum samples based on a molecularly imprinted polymer membrane
    Paniagua Gonzalez, Gema
    Fernandez Hernando, Pilar
    Durand Alegria, J. S.