A MIP-based flow-through fluoroimmunosensor as an alternative to immunosensors for the determination of digoxin in serum samples

被引:17
|
作者
Paniagua Gonzalez, Gema [1 ]
Fernandez Hernando, Pilar [1 ]
Durand Alegria, Jesus Senen [1 ]
机构
[1] Univ Nacl Educ Distancia, Fac Ciencias, Dept Ciencias Analit, E-28040 Madrid, Spain
关键词
Digoxin; Permanent immobilisation; Molecular imprinting; Flow-through fluorosensor; Serum analysis; ANTIBODIES;
D O I
10.1007/s00216-008-2584-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This work reports a comparative study of two automated flow-through fluorosensors for the determination of digoxin in serum samples: an immunosensor with an anti-digoxin polyclonal antibody as the reactive phase permanently immobilised on controlled-pore glass and a sensor with a selective reaction system based on a methacrylic molecularly imprinted polymer (MIP) synthesised by bulk polymerisation. The variables affecting the sensitivity and dynamic range of the sensors (e.g. the carrier and elution solutions, flow rates, pH and reagent concentrations) were optimized, and the binding characteristics of their reactive phases were compared in a competitive fluorescent assay. Digoxin was reproducibly determined by both sensors at the milligram per litre level (detection limit = 1.20 x 10(-3) mg L-1 and RSD = 4-7% for the immunosensor; detection limit = 1.7 x 10(-5) mg L-1 and RSD = 1-2% for the MIP sensor). No cross-reactivity with digoxin-related compounds was seen for either sensor at a digoxin/interferent ratio of 1:100. The lifetime of the immunosensor was about 50 immunoassays; its shelf life, when unused, is about 3 months. The lifetime of the MIP sensor was over 18 months. Both sensors were used to determine the digoxin concentration of human serum samples with satisfactory results.
引用
收藏
页码:963 / 970
页数:8
相关论文
共 50 条
  • [1] A MIP-based flow-through fluoroimmunosensor as an alternative to immunosensors for the determination of digoxin in serum samples
    Gema Paniagua González
    Pilar Fernández Hernando
    Jesús Senén Durand Alegría
    Analytical and Bioanalytical Chemistry, 2009, 394 : 963 - 970
  • [2] Permanently oriented antibody immobilization for digoxin determination with a flow-through fluoroimmunosensor
    P Fernández
    JS Durand
    C Pérez-Conde
    G Paniagua
    Analytical and Bioanalytical Chemistry, 2003, 375 : 1020 - 1023
  • [3] Permanently oriented antibody immobilization for digoxin determination with a flow-through fluoroimmunosensor
    Fernández, P
    Durand, JS
    Pérez-Conde, C
    Paniagua, G
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (08) : 1020 - 1023
  • [4] Determination of digoxin in serum samples using a flow-through fluorosensor based on a molecularly imprinted polymer
    Gonzalez, Gema Paniagua
    Hernando, Pilar Fernandez
    Alegria, J. S. Durand
    BIOSENSORS & BIOELECTRONICS, 2008, 23 (11): : 1754 - 1758
  • [5] Oriented antibody immobilization for atrazine determination by a flow-through fluoroimmunosensor
    E. Turiel
    P. Fernández
    C. Pérez-Conde
    A. M. Gutiérrez
    C. Cámara
    Fresenius' Journal of Analytical Chemistry, 1999, 365 : 658 - 662
  • [6] Oriented antibody immobilization for atrazine determination by a flow-through fluoroimmunosensor
    Turiel, E
    Fernández, P
    Pérez-Conde, C
    Gutiérrez, AM
    Cámara, C
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (08): : 658 - 662
  • [7] Determination of creatinine in clinical samples based on flow-through microsystem
    Grabowska, I
    Chudy, M
    Dybko, A
    Brzozka, Z
    ANALYTICA CHIMICA ACTA, 2005, 540 (01) : 181 - 185
  • [8] Validation of a smartphone-compatible MIP-based sensor for bisphenol A determination in wastewater samples
    Yarynka, Daria
    Honcharenko, Anton
    Gorbach, Larysa
    Piletska, Elena
    Piletsky, Sergey
    Brovko, Oleksandr
    Sergeyeva, Tetyana
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (29) : 7121 - 7129
  • [9] Flow-through fluoroimmunosensor for isoproturon determination in agricultural foodstuff -: Evaluation of antibody immobilization on solid support
    Pulido-Tofiño, P
    Barrero-Moreno, JM
    Pérez-Conde, MC
    ANALYTICA CHIMICA ACTA, 2000, 417 (01) : 85 - 94
  • [10] Flow-through fluorescence immunosensor for IgG determination in serum
    DiazGarcia, ME
    delosToyos, JR
    Sampedro, A
    ValenciaGonzalez, MJ
    SalasBustamante, A
    MEDICAL AND FIBER OPTIC SENSORS AND DELIVERY SYSTEMS, PROCEEDINGS OF, 1996, 2631 : 37 - 44