Study on Energy Performance of Passive Zone and Non-passive Zone in Office Buildings

被引:0
|
作者
Zhu, Panyu [1 ]
Yan, Da [1 ]
Sun, Hongsan [1 ]
Huang, Yu [2 ]
Jin, Yuan [1 ]
机构
[1] Tsinghua Univ, Sch Architecture, Beijing 100084, Peoples R China
[2] Guangzhou Univ, Sch Civil Engn, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
DESIGN; SHAPE;
D O I
10.1088/1755-1315/238/1/012008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Building form has great influence on energy performance. However, the indoor volume was usually considered as a whole and the difference between perimeter (passive zone) and core (non-passive zone) were rarely discussed. Actually, the energy performance of perimeter space is very unlike the core because of the accessibility to building envelope. The distribution of passive zones has direct influence on building form as well as energy use. In this paper, energy performance of passive and non-passive zones were studied by numerical simulations in three Chinese cities. Results indicate that passive zones normally require more thermal energy than non-passive zone in severe cold climate zone (Urumqi), while south-orientated passive zone could achieve less thermal demand in cold climate zone (Beijing and Lhasa). Among different orientations, the highest and lowest annual energy demand occurs in north- and south-orientated zone, respectively. High potential of energy saving on the west orientation is also noticed. When natural ventilation or window shading are considered, energy demand in west-orientated passive zone could be even lower than non-passive zone in Beijing and Lhasa. Understanding the energy performance of passive and non-passive zone could help to guide building design with the aim of energy saving in the future.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Stability and performance of haptic simulation involving interaction with non-passive virtual environment
    Kim, Myeongjin
    Lee, Doo Yong
    [J]. ROBOTICA, 2019, 37 (03) : 560 - 574
  • [22] Energy saving with passive climate control methods in Spanish office buildings
    Orosa, Jose A.
    Oliveira, Armando C.
    [J]. ENERGY AND BUILDINGS, 2009, 41 (08) : 823 - 828
  • [23] Robust control of non-passive systems via passification
    Kelkar, AG
    Joshi, SM
    [J]. PROCEEDINGS OF THE 1997 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 1997, : 2657 - 2661
  • [24] A performance comparison of passive and low-energy buildings
    Mahdavi, Ardeshir
    Doppelbauer, Eva-Maria
    [J]. ENERGY AND BUILDINGS, 2010, 42 (08) : 1314 - 1319
  • [25] A critique of the passive zone concept for energy conservation design tools
    Hyde, R.
    Pedrini, A.
    [J]. Architectural Science Review, 2001, 44 (02) : 153 - 160
  • [26] Controlled Natural Ventilation Coupled with Passive PCM System to Improve the Cooling Energy Performance in Office Buildings
    Saffari, Mohammad
    Prabhakar, Mohit
    de Gracia, Alvaro
    Mangina, Eleni
    Finn, Donal P.
    Cabeza, Luisa F.
    [J]. PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 1732 - 1739
  • [27] LMI-Based passification for control of non-passive systems
    Kelkar, AG
    Mao, Y
    Joshi, SM
    [J]. PROCEEDINGS OF THE 2000 AMERICAN CONTROL CONFERENCE, VOLS 1-6, 2000, : 1271 - 1275
  • [28] Passive Solar Energy in Buildings
    Kacham, Shiva Teja
    Wawrzon, Jerome
    Rahman, Muhammad Mukhlesur
    Patnaikuni, Indubhushan
    [J]. RECENT ADVANCES IN ENVIRONMENTAL SCIENCE FROM THE EURO-MEDITERRANEAN AND SURROUNDING REGIONS, VOLS I AND II, 2018, : 1491 - 1492
  • [29] A Lagrangian Particle Transport and Diffusion Model for Non-passive Scalars
    Kaplan, H.
    [J]. BOUNDARY-LAYER METEOROLOGY, 2015, 156 (01) : 37 - 52
  • [30] Energy consumption modelling of a passive hybrid system for office buildings in different climates
    Zhang, Yi
    Tennakoon, Thilhara
    Chan, Yin Hoi
    Chan, Ka Chung
    Fu, Sau Chung
    Tso, Chi Yan
    Yu, Kin Man
    Huang, Bao Ling
    Yao, Shu Huai
    Qiu, Hui He
    Chao, Christopher Y. H.
    [J]. ENERGY, 2022, 239