Effects of intraoral aging on surface properties of coated nickel-titanium archwires

被引:41
|
作者
Rongo, Roberto [1 ]
Ametrano, Gianluca [1 ]
Gloria, Antonio [2 ]
Spagnuolo, Gianrico [1 ]
Galeotti, Angela [3 ]
Paduano, Sergio [4 ]
Valletta, Rosa [1 ]
D'Anto, Vincenzo [1 ,5 ]
机构
[1] Univ Naples Federico II, Dept Neurosci Reprod Sci & Oral Sci, I-80131 Naples, Italy
[2] CNR, Inst Composite & Biomed Mat, Naples, Italy
[3] Bambino Gesu Pediat Hosp, Dept Pediat Surg, Div Dent, Rome, Italy
[4] Univ Catanzaro Magna Grecia, Sch Dent, Catanzaro, Italy
[5] Bambino Gesu Pediat Hosp, Dept Pediat Surg, Rome, Italy
关键词
Orthodontic archwire; Surface roughness; Surface treatment; Atomic force microscopy; Retrieved analysis; ATOMIC-FORCE MICROSCOPY; ORTHODONTIC ARCHWIRES; WIRES; RESISTANCE; ROUGHNESS; INSTRUMENTS; STABILITY; CORROSION;
D O I
10.2319/081213-593.1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the effects of intraoral aging on surface properties of esthetic and conventional nickel-titanium (NiTi) archwires. Materials and Methods: Five NiTi wires were considered for this study (Sentalloy, Sentalloy High Aesthetic, Superelastic Titanium Memory Wire, Esthetic Superelastic Titanium Memory Wire, and Ever White). For each type of wire, four samples were analyzed as received and after 1 month of clinical use by an atomic force microscope (AFM) and a scanning electronic microscope (SEM). To evaluate sliding resistance, two stainless steel plates with three metallic or three monocrystalline brackets, bonded in passive configuration, were manufactured; four as-received and retrieved samples for every wire were pulled five times at 5 mm/min for 1 minute by means of an Instron 5566, recording the greatest friction value (N). Data were analyzed by one-way analysis of variance and by Student's t-test. Results: After clinical use, surface roughness increased considerably. The SEM images showed homogeneity for the as-received control wires; however, after clinical use esthetic wires exhibited a heterogeneous surface with craters and bumps. The lowest levels of friction were observed with the as-received Superelastic Titanium Memory Wire on metallic brackets. When tested on ceramic brackets, all the wires exhibited an increase in friction (t-test; P < .05). Furthermore, all the wires, except Sentalloy, showed a statistically significant increase in friction between the as-received and retrieved groups (t-test; P < .05). Conclusion: Clinical use of the orthodontic wires increases their surface roughness and the level of friction.
引用
收藏
页码:665 / 672
页数:8
相关论文
共 50 条
  • [41] NICKEL-TITANIUM (NI-TI) ALLOYS FROM THE COMPOSITION OF ORTHODONTIC ARCHWIRES
    Teodorescu, Elina
    Galan, Elena
    Milicescu, Stefan, Jr.
    Pascu, Raluca
    Ionescu, Ileana
    Ionescu, Ecaterina
    METALURGIA INTERNATIONAL, 2010, 15 : 19 - 23
  • [42] THE EFFECT OF LONG-TERM DEFLECTION ON PERMANENT DEFORMATION OF NICKEL-TITANIUM ARCHWIRES
    HUDGINS, JJ
    BAGBY, MD
    ERICKSON, LC
    ANGLE ORTHODONTIST, 1990, 60 (04) : 283 - 288
  • [43] Corrosion resistance of surface modified nickel titanium archwires
    Krishnan, Manu
    Seema, Saraswathy
    Kumar, A. Vinod
    Varthini, N. Parvatha
    Sukumaran, Kalathil
    Pawar, Vasant R.
    Arora, Vimal
    ANGLE ORTHODONTIST, 2014, 84 (02) : 358 - 367
  • [44] Galvanic corrosion of metal injection molded (MIM) and conventional brackets with nickel-titanium and copper-nickel-titanium archwires
    Siargos, Barbara
    Bradley, Thomas G.
    Darabara, Myrsini
    Papadimitriou, George
    Zinelis, Spiros
    ANGLE ORTHODONTIST, 2007, 77 (02) : 355 - 360
  • [45] Effectiveness of tubular coaxial nickel- titanium and copper nickel-titanium orthodontic aligning archwires: A randomized clinical trial
    Noori, Reyam M.
    Yassir, Yassir A.
    INTERNATIONAL ORTHODONTICS, 2023, 21 (04)
  • [46] Surface Characteristics of Esthetic Nickel-Titanium and Beta-Titanium Orthodontic Archwires Produced by Plasma Electrolytic Oxidation (PEO)Primary Results
    Jung, Ole
    Becker, Jean-Philippe
    Smeets, Ralf
    Gosau, Martin
    Becker, Germain
    Kahl-Nieke, Baerbel
    Jung, Anne-Kathrin
    Heiland, Max
    Kopp, Alexander
    Barbeck, Mike
    Koehne, Till
    MATERIALS, 2019, 12 (09)
  • [47] Comparative Evaluation of Load-deflection Property of Different Brands of Nickel-titanium Archwires
    Bhat, Faiz Ahmad
    Shetty, Nandish
    Khan, Faizan Ahmad
    Bhat, Muraleedhara
    Husain, Akhter
    APOS TRENDS IN ORTHODONTICS, 2018, 8 (02) : 92 - 95
  • [48] Analysis of Intrusion Forces in Stainless Steel and Nickel-Titanium Orthodontic Archwires: An Experimental Study
    Magesh, Varadaraju
    Harikrishnan, Pandurangan
    Nishad, Rachit
    Kapre, Atharva
    Chatterjee, Raunak
    Trends in Biomaterials and Artificial Organs, 2024, 38 (01): : 1 - 4
  • [49] Surface and cross-sectional characterization of titanium-nitride coated nickel-titanium endodontic files
    Al Jabbari, Youssef S.
    Koutsoukis, Theodoros
    Al Hadlaq, Suliman
    Berzins, David W.
    Zinelis, Spiros
    JOURNAL OF DENTAL SCIENCES, 2016, 11 (01) : 48 - 53
  • [50] Dynamic properties of nickel-titanium alloys
    Hackenberg, R
    Swift, D
    Bourne, N
    Gray, G
    Paisley, D
    Thoma, D
    Cooley, J
    Hauer, A
    SHOCK COMPRESSION OF CONDENSED MATTER - 2003, PTS 1 AND 2, PROCEEDINGS, 2004, 706 : 561 - 564