Analysis of Intrusion Forces in Stainless Steel and Nickel-Titanium Orthodontic Archwires: An Experimental Study

被引:0
|
作者
Magesh, Varadaraju [1 ]
Harikrishnan, Pandurangan [2 ,3 ]
Nishad, Rachit [1 ]
Kapre, Atharva [1 ]
Chatterjee, Raunak [1 ]
机构
[1] Department of Mechanical Engineering, College of Engineering and Technology, SRM Institute of Science and Technology, Chengalpattu, Tamil Nadu, Kattankulathur,603203, India
[2] Department of Orthodontics, JKKN Dental College, Tamil Nadu, Komarapalayam, India
[3] Teeth N Jaws Center, Lake Area, Nungambakkam, Chennai,600034, India
来源
关键词
Bending tests - Binary alloys - Nickel - Titanium;
D O I
暂无
中图分类号
学科分类号
摘要
Orthodontics involves alignment of improperly positioned teeth mostly with fixed appliances. Round archwires are commonly used for intrusion of anterior teeth. The aim of this study was to measure the magnitude of force required to deflect the archwire for 2 mm between central and lateral incisors. To mimic the real oral domain, an experimental set-up with maxilla and mandible with metallic teeth was constructed. Orthodontic brackets (0.018 x 0.025) were bonded on the metal tooth and 0.016 Stainless steel (SS) and Nickel Titanium (NiTi) archwires were used with SS ligature. The archwire is deflected for 2 mm and a three point bending test was performed to measure the force magnitude using a six-axis spine tester. The forces from NiTi and SS archwires were 10.3 N and 11.4 N respectively in the maxilla, and 13.2 N and 15.3 N respectively in the mandible. As the deflection increases the loading forces also increase and is higher in SS than NiTi. Clinicians can thus select their wire deflection for the amount of force needed for intrusion planning. © (2024) Society for Biomaterials & Artificial Organs #20004424.
引用
收藏
页码:1 / 4
相关论文
共 50 条
  • [1] Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires
    Kim, H
    Johnson, JW
    ANGLE ORTHODONTIST, 1999, 69 (01) : 39 - 44
  • [2] Characteristics of Sterilised Nickel Titanium and Stainless Steel Orthodontic Archwires
    Abood, Akhlas Zeid
    Noor, Siti Noor Fazliah Mohd
    Suhaimi, Fatanah Mohamad
    Al-Fatlawi, Fakhri Abid Ali Hussein
    Shafiai, Noor Ayuni Ahmad
    JOURNAL OF PHYSICAL SCIENCE, 2024, 35 (03) : 27 - 48
  • [3] Comparative assessment of the corrosion process of orthodontic archwires made of stainless steel, titanium-molybdenum and nickel-titanium alloys
    Malkiewicz, Konrad
    Sztogryn, Mariola
    Mikulewicz, Marcin
    Wielgus, Andrzej
    Kaminski, Janusz
    Wierzchon, Tadeusz
    ARCHIVES OF CIVIL AND MECHANICAL ENGINEERING, 2018, 18 (03) : 941 - 947
  • [4] Tribocorrosive Study of New and In Vivo Exposed Nickel Titanium and Stainless Steel Orthodontic Archwires
    Kosec, Tadeja
    Macnik, Petra
    Mezeg, Uros
    Legat, Andraz
    Ovsenik, Maja
    Jenko, Monika
    Grant, John T.
    Primozic, Jasmina
    COATINGS, 2020, 10 (03)
  • [5] In vitro biocompatibility of nickel-titanium esthetic orthodontic archwires
    Rongo, Roberto
    Valletta, Rosa
    Buccia, Rosaria
    Rivieccio, Virginia
    Galeotti, Angela
    Michelotti, Ambrosina
    D'Anto, Vincenzo
    ANGLE ORTHODONTIST, 2016, 86 (05) : 789 - 795
  • [6] Comparison of Elastic Properties of Nickel-Titanium Orthodontic Archwires
    Sarul, Michal
    Kawala, Beata
    Antoszewska, Joanna
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2013, 22 (02): : 253 - 260
  • [7] A comparison of the bending behaviour of nickel-titanium orthodontic archwires
    Lester, KJ
    Mori, T
    Sims, MR
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 937 - 937
  • [8] Thermal and mechanical characteristics of stainless steel, titanium-molybdenum, and nickel-titanium archwires
    Kusy, Robert P.
    Whitley, John Q.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (02) : 229 - 237
  • [9] FRICTION OF STAINLESS STEEL, NICKEL-TITANIUM ALLOY, AND BETA-TITANIUM ALLOY ARCHWIRES IN TWO COMMONLY USED ORTHODONTIC BRACKETS
    Yu, Jian-Hong
    Huang, Heng-Li
    Wu, Li-Chun
    Hsu, Jui-Ting
    Chang, Yin-Yu
    Huang, Her-Hsiung
    Tsai, Ming-Tzu
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2011, 11 (04) : 917 - 928
  • [10] COMPARISONS OF THE THERMODYNAMIC PROPERTIES OF 3 NICKEL-TITANIUM ORTHODONTIC ARCHWIRES
    BISHARA, SE
    ORTHO, D
    WINTERBOTTOM, JM
    SULIEMAN, AHA
    RIM, K
    JAKOBSEN, JR
    ANGLE ORTHODONTIST, 1995, 65 (02) : 117 - 122