Developing a Source Model for the Elekta Unity MR-Linac Using a Grid-Based Boltzmann Solver

被引:0
|
作者
Nowak, S. [1 ]
Hyer, D. [1 ]
Yang, R. [2 ]
St-Aubin, J. [1 ]
机构
[1] Univ Iowa, Iowa City, IA USA
[2] Cross Canc Inst, Edmonton, AB, Canada
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-I400-Ge
引用
收藏
页码:E159 / E159
页数:1
相关论文
共 50 条
  • [21] Experimental Verification of the Electron Return Effect in Lung Heterogeneity Measurements On Elekta Unity MR-Linac
    Tyagi, N.
    Liang, J.
    Scripes, P.
    Subashi, E.
    Moran, J.
    Chan, M.
    Lim, S.
    MEDICAL PHYSICS, 2022, 49 (06) : E769 - E769
  • [22] Neutron Dose Measurements in the Elekta MR-Linac Using Bubble Detectors
    Keller, B.
    Nusrat, H.
    Ahmad, S.
    Al-Ward, S.
    Sahgal, A.
    Sarfehnia, A.
    Breen, S.
    Pang, G.
    MEDICAL PHYSICS, 2018, 45 (06) : E122 - E123
  • [23] MRI B0 homogeneity and geometric distortion with continuous linac gantry rotation on an Elekta Unity MR-linac
    Jackson, Steven
    Glitzner, Markus
    Tijssen, Rob H. N.
    Raaymakers, Bas W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (12):
  • [24] Treatment Verification of the Elekta Unity MR-Linac Adapted Workflow Using in Vivo 3D EPID Dosimetry
    Ruiz, I. Olaciregui
    Xirau, I. Torres
    van der Heide, U.
    Mans, A.
    MEDICAL PHYSICS, 2019, 46 (06) : E367 - E367
  • [25] Proof-of-concept delivery of intensity modulated arc therapy on the Elekta Unity 1.5 T MR-linac
    Kontaxis, C.
    Woodhead, P. L.
    Bol, G. H.
    Lagendijk, J. J. W.
    Raaymakers, B. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (04):
  • [26] Real-Time Adaptive Dose Scaling During MLC-Tracking on the Elekta Unity MR-Linac
    Borman, P. T. S.
    Woodhead, P. L.
    Uijtewaal, P.
    Hackett, S. L.
    Lagendijk, J. J. W.
    Raaymakers, B. W.
    Fast, M. F.
    MEDICAL PHYSICS, 2020, 47 (06) : E437 - E437
  • [27] Superparamagnetic Iron Oxide Enhanced MRI for Elekta Unity MR-Linac: A Pre-Clinical Phantom Study
    Lee, D.
    Klepchick, P.
    Lee, H.
    Pavord, D.
    Oh, S.
    Sohn, J.
    Kirichenko, A.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [28] Is it necessary to perform measurement-based patient-specific quality assurance for online adaptive radiotherapy with Elekta Unity MR-Linac?
    Xu, Yuan
    Xia, Wenlong
    Ren, Wenting
    Ma, Min
    Men, Kuo
    Dai, Jianrong
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (02):
  • [29] Out-Of-Field Radiation Dose Considerations in Partial Breast Irradiation with Elekta Unity MR-Linac - a Feasibility Study
    Muruganandham, M.
    Lee, B.
    Vedam, S.
    Wang, J.
    Yang, J.
    Salehpour, M.
    Shaitelman, S.
    MEDICAL PHYSICS, 2020, 47 (06) : E645 - E645
  • [30] Dosimetric verification of Elekta MR-linac adaption workflow using 3D dosimeters
    Costa, F.
    Hanson, I.
    Doran, S.
    Adamovics, J.
    Nill, S.
    Oelfke, U.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S248 - S249