Determination of synephrine in feeds by a novel quick, easy, cheap, effective, rugged, and safe solid-phase extraction method combined with UHPLC-MS/MS

被引:7
|
作者
Song, Yue [1 ,2 ]
Chai, Tingting [3 ]
Lou, Shengting [1 ,2 ]
Zhao, Yuechen [1 ,2 ]
Zhang, Xining [1 ,2 ]
Yang, Shuming [1 ,2 ]
Qian, Yongzhong [1 ,2 ]
Qiu, Jing [1 ,2 ]
机构
[1] Chinese Acad Agr Sci, Inst Qual Stand Testing Technol Agroprod, Key Lab Agroprod Qual & Safety, Beijing 100081, Peoples R China
[2] Minist Agr, Key Lab Agrifood Qual & Safety, Beijing, Peoples R China
[3] Zhejiang A&F Univ, Coll Agr & Food Sci, Key Lab Qual Improvement Agr Prod Zhejiang Prov, Hangzhou, Zhejiang, Peoples R China
关键词
feed; solid-phase extraction; synephrine; tandem mass spectrometry; ultra high performance liquid chromatography; PORTAL HYPERTENSIVE-RATS; CITRUS-AURANTIUM; P-SYNEPHRINE; DIETARY-SUPPLEMENTS; CAPILLARY-ELECTROPHORESIS; FRUIT; SEPARATION; PRODUCTS; EXERCISE; PEEL;
D O I
10.1002/jssc.201701194
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To detect and quantify synephrine in feed, an effective analytical method based on quick, easy, cheap, effective, rugged, and safe solid-phase extraction coupled to ultra high performance liquid chromatography with tandem mass spectrometry was developed with isotopic internal standards. Pretreatment was performed using quick, easy, cheap, effective, rugged, and safe solid-phase extraction with primary secondary amine and C18 sorbent as sorbents in combination with Oasis MCX column cleanup to extract and purify feed samples. Tandem mass spectrometry detection in positive ion mode was conducted in positive multiple reaction monitoring mode in addition to the quantitative internal standard method. Two transitions of synephrine at m/z 168.1/150.0 and 168.1/135.0 were selected, and m/z 168.1/135.0 was determined as the quantification ion pair. D-9-Terbutaline was selected as an internal standard, for which m/z 235.1/153.0 was selected as the quantification ion pair. Good linearity was shown for synephrine in the range of 0.5-50 mu g/L, and the correlation coefficient exceeded 0.999. The recoveries in three different feed samples at three spiked levels were 81.42-112.08%, and the relative standard deviations were not greater than 14.66%. The method proposed in this study was reliable and highly effective, and its sensitivity, accuracy, and precision are suitable for determining synephrine residues in feed samples.
引用
收藏
页码:1743 / 1751
页数:9
相关论文
共 50 条
  • [31] Analysis of Heterocyclic Amines in Meat by the Quick, Easy, Cheap, Effective, Rugged, and Safe Method Coupled with LC-DAD-MS-MS (vol 65, pg 9360, 2017)
    Hsiao, Han-Yin
    Chen, Bing-Huei
    Kao, Tsai-Hua
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2017, 65 (51) : 11329 - 11329
  • [32] Rapid screening of amitraz and its metabolite residues in honey using a quick, easy, cheap, effective, rugged, and safe extraction method coupled with UHPLC and Q Exactive
    Li, Yanping
    Li, Yuxiang
    Yang, Yan
    JOURNAL OF SEPARATION SCIENCE, 2020, 43 (08) : 1466 - 1473
  • [33] Determination of steroid hormones in sediments based on quick, easy, cheap, effective, rugged, and safe (modified-QuEChERS) extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
    Camilleri, Julien
    Vulliet, Emmanuelle
    ANALYTICAL METHODS, 2015, 7 (22) : 9577 - 9586
  • [34] Analysis of aristolochic acid I in mouse serum and tissues by using magnetic solid-phase extraction and UHPLC-MS/MS
    Guo, Wenjing
    Shi, Zhangsheng
    Zhang, Jing
    Zeng, Ting
    He, Yu
    Cai, Zongwei
    TALANTA, 2021, 235
  • [35] Dissipation of tiafenacil in five types of citrus orchard soils using the HPLC-MS coupled with the quick, easy, cheap, effective, rugged, and safe method
    Gao, Meizhu
    Bian, Chuanfei
    Zhou, Wenwen
    Liu, Lang
    Li, Baotong
    Tang, Limei
    JOURNAL OF SEPARATION SCIENCE, 2021, 44 (09) : 1961 - 1968
  • [36] New sorbent in the dispersive solid phase extraction step of quick, easy, cheap, effective, rugged, and safe for the extraction of organic contaminants in drinking water treatment sludge
    Cerqueira, Maristela B. R.
    Caldas, Sergiane S.
    Primel, Ednei G.
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1336 : 10 - 22
  • [37] Development of an Enhanced Quick, Easy, Cheap, Effective, Rugged, and Safe Method for Determination of Quinolone Drug Residues in Quail Eggs
    Liu, Chuan
    Lin, Hao
    Yao, Jing
    Chen, Yan-Qiu
    Shi, Pei-Yu
    Song, Juan
    Mao, Rui
    Xiao, Quan-Wei
    Dai, Qin
    SEPARATION SCIENCE PLUS, 2024,
  • [38] Determination of 57 pesticide residues in fishery products by GC tandem mass spectrometry combined with QuEChERS (quick, easy, cheap, effective, rugged, and safe) extraction
    Lee, Hyesu
    Kim, Myungheon
    Park, Minsoo
    Cho, Mihyun
    Hur, Jun Wook
    Lee, Yoonmi
    Jo, Mi-Ra
    Lee, Joon-Goo
    Im, Moo-Hyeog
    FOOD SCIENCE AND BIOTECHNOLOGY, 2024, 33 (04) : 831 - 853
  • [39] Determination of 57 pesticide residues in fishery products by GC tandem mass spectrometry combined with QuEChERS (quick, easy, cheap, effective, rugged, and safe) extraction
    Hyesu Lee
    Myungheon Kim
    Minsoo Park
    Mihyun Cho
    Jun Wook Hur
    Yoonmi Lee
    Mi-Ra Jo
    Joon-Goo Lee
    Moo-Hyeog Im
    Food Science and Biotechnology, 2024, 33 : 831 - 853
  • [40] Simultaneous extraction and determination of antibiotics in soils using a method based on quick, easy, cheap, effective, rugged, and safe extraction and liquid chromatography with tandem mass spectrometry
    Meng, Minghui
    He, Zeying
    Xu, Yaping
    Wang, Lu
    Peng, Yi
    Liu, Xiaowei
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (16) : 3214 - 3220