Experimental results from short-circuit faults on a distribution transformer

被引:0
|
作者
Butler, KL [1 ]
Kuforiji, A [1 ]
机构
[1] Texas A&M Univ, Power Syst Automat Lab, College Stn, TX 77843 USA
关键词
distribution transformer; field experiments; short circuit faults;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
In an effort to characterize the behavior of the terminal values (primary and secondary voltages and currents) of a distribution transformer during internal short circuit and incipient faults, experiments were performed on a custom-built transformer. This single phase 25 kVA, 7200V/240V/120V two winding transformer included twelve taps distributed on turns along the primary winding and similarly 12 taps distributed along the secondary winding for the purpose of staging faults that involved short circuits of sections of winding turns. The experiments were performed at the downed conductor testing facility at Texas A&M University over an 19 - month period. This paper describes the experimental setup and presents and discusses the results obtained during the experiments.
引用
收藏
页码:299 / 306
页数:8
相关论文
共 50 条
  • [31] Electromagnetic Effects of Short-Circuit Faults in Induction Machines
    Hachelaf R.
    Kouchih D.
    Tadjine M.
    Boucherit M.S.
    Russian Electrical Engineering, 2023, 94 (06) : 442 - 447
  • [32] SHORT-CIRCUIT CALCULATIONS FOR MULTILINE SWITCHING AND END FAULTS
    DYLIACCO, TE
    RAMARAO, KA
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1970, PA89 (06): : 1226 - &
  • [33] A Novel Characterization Method for Transformer Interturn Short-Circuit Faults Based on Arc-Induced Transients
    Liu, Hao
    Yan, Chenguang
    Yang, Hongxi
    Yang, Xiao
    Zhang, Peng
    Zhang, Baohui
    2024 IEEE INTERNATIONAL MAGNETIC CONFERENCE-SHORT PAPERS, INTERMAG SHORT PAPERS, 2024,
  • [34] Differential Protection Performance for Converter Transformer Intertap Short-Circuit Faults in On-Load Tap Changers
    Yan C.
    Zhang P.
    Xu Y.
    Wu J.
    Li L.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2023, 38 (21): : 5878 - 5912
  • [35] Effects of internal short circuit faults on short circuit reactance of power transformer
    Wang, Zan-Ji
    Tang, Qi-Chao
    Liu, Xiu-Cheng
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2006, 26 (21): : 15 - 21
  • [36] High frequency short-circuit inductance for transformer at transformer limited fault
    Koshizuka T.
    Haginomori E.
    Taniguchi Y.
    Ikeda H.
    Harada K.
    Koshizuka, Tadashi (tadashi.koshizuka@mail.dendai.ac.jp), 1600, Institute of Electrical Engineers of Japan (136): : 596 - 601
  • [37] A Calculation Method to Adjust the Short-Circuit Impedance of a Transformer
    Ye, Zhijun
    Yu, Wang
    Gou, Julong
    Tan, Kaijia
    Zeng, Wenhui
    An, Bonan
    Li, Yong
    IEEE ACCESS, 2020, 8 : 223848 - 223858
  • [38] Experimental Research on Cumulative Deformation of Transformer Winding Induced by Short-Circuit Current Impacts
    Ren, Fuqiang
    Ji, Shengchang
    Zhu, Lingyu
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 1, 2020, 598 : 625 - 634
  • [39] Calculation of Transformer Internal Faults in Short Circuit Analysis
    Ghanavati, G.
    Kouhsari, S. M.
    Koochaki, A.
    Mahmoodan, M.
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 2131 - 2137
  • [40] TLM modeling of transformer with internal short circuit faults
    Ozgonenel, Okan
    Thomas, David W. P.
    Christopoulos, Christos
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2007, 26 (05) : 1304 - 1323