Experimental results from short-circuit faults on a distribution transformer

被引:0
|
作者
Butler, KL [1 ]
Kuforiji, A [1 ]
机构
[1] Texas A&M Univ, Power Syst Automat Lab, College Stn, TX 77843 USA
关键词
distribution transformer; field experiments; short circuit faults;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
In an effort to characterize the behavior of the terminal values (primary and secondary voltages and currents) of a distribution transformer during internal short circuit and incipient faults, experiments were performed on a custom-built transformer. This single phase 25 kVA, 7200V/240V/120V two winding transformer included twelve taps distributed on turns along the primary winding and similarly 12 taps distributed along the secondary winding for the purpose of staging faults that involved short circuits of sections of winding turns. The experiments were performed at the downed conductor testing facility at Texas A&M University over an 19 - month period. This paper describes the experimental setup and presents and discusses the results obtained during the experiments.
引用
收藏
页码:299 / 306
页数:8
相关论文
共 50 条
  • [21] TANGENT FORCES IN TRANSFORMER WINDINGS AT SHORT-CIRCUIT
    LURIE, AI
    ZENOVA, VP
    PANIBRATETZ, AN
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 1992, 11 (01) : 133 - 136
  • [22] Short-Circuit Performance Analysis of a Distribution Transformer Using Coupled Field-Circuit Approach
    Al-Dori, Osamah
    Donuk, Atilla
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2024, 52 (04) : 629 - 640
  • [23] Short-circuit current limitation by superconducting transformer
    Janowski, Tadeusz
    Wojtasiewicz, Grzegorz
    Jaroszynski, Leszek
    2016 13TH SELECTED ISSUES OF ELECTRICAL ENGINEERING AND ELECTRONICS (WZEE), 2016,
  • [24] Short-Circuit Electromagnetic Force Distribution Characteristics in Transformer Winding Transposition Structures
    Zhao, Yi
    Chen, Weijiang
    Jin, Mingkai
    Wen, Tao
    Xue, Jiyin
    Zhang, Qiaogen
    Chen, Ming
    IEEE TRANSACTIONS ON MAGNETICS, 2020, 56 (12)
  • [25] Experimental Analysis of Short-Circuit Effects in Transformer Winding by Impact Test and SFRA
    Gutten, Miroslav
    Janura, Richard
    Korenciak, Daniel
    PROCEEDINGS OF 2016 INTERNATIONAL CONFERENCE ON DIAGNOSTIC OF ELECTRICAL MACHINES AND INSULATING SYSTEMS IN ELECTRICAL ENGINEERING (DEMISEE 2016), 2016, : 77 - 80
  • [26] A 3D-coupled field-circuit model for analyzing the internal short-circuit faults of power transformer
    Hu, Guozhao
    Wu, Xixiu
    Long, Fei
    Wu, Shipu
    Lecture Notes in Electrical Engineering, 2015, 334 : 55 - 64
  • [27] Research on Short-Circuit Force of Distribution Transformer Based on Short-Circuit Test by Single-Phase Power and Three-phase Power
    Luo, Xiaoxiao
    Xiao, Qianbo
    Wang, Qian
    Gan, Wenyan
    Deng, Baojia
    Fang, Chaohong
    2021 3RD ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM (AEEES 2021), 2021, : 89 - 93
  • [28] Efficient Methodology for Detection and Classification of Short-Circuit Faults in Distribution Systems with Distributed Generation
    Santos, Andreia da Silva
    Faria, Lucas Teles
    Lopes, Mara Lucia M.
    Lotufo, Anna Diva P.
    Minussi, Carlos R. R.
    SENSORS, 2022, 22 (23)
  • [29] Methods of short-circuit test for large power transformer and introduction of short-circuit test for four transformers
    Chen, Kui
    Bianyaqi/Transformer, 35 (01): : 12 - 16
  • [30] CALCULATING THE SHORT-CIRCUIT IMPEDANCES OF A MULTIWINDING TRANSFORMER FROM ITS GEOMETRY
    NIEMELA, VA
    SKUTT, GR
    URLING, AM
    CHANG, YN
    WILSON, TG
    OWEN, HA
    WONG, RC
    PESC 89 RECORD, VOLS 1 AND 2: 20TH ANNUAL IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, 1989, : 607 - 617