Functional Data Analysis of Dynamic PET Data

被引:6
|
作者
Chen, Yakuan [1 ]
Goldsmith, Jeff [2 ]
Ogden, R. Todd [2 ]
机构
[1] AT&T Serv Inc, 200 South Laurel Ave, Middletown, NJ 07080 USA
[2] Columbia Univ, Mailman Sch Publ Hlth, New York, NY USA
关键词
Bootstrap; Constrained estimation; Function-on-scalar regression; Nonparametric; Splines; POSITRON-EMISSION-TOMOGRAPHY; SEROTONIN TRANSPORTER BINDING; IN-VIVO QUANTIFICATION; PARAMETERS; MODELS; C-11-DASB; HUMANS; BRAIN;
D O I
10.1080/01621459.2018.1497495
中图分类号
O21 [概率论与数理统计]; C8 [统计学];
学科分类号
020208 ; 070103 ; 0714 ;
摘要
One application of positron emission tomography (PET), a nuclear imaging technique, in neuroscience involves in vivo estimation of the density of various proteins (often, neuroreceptors) in the brain. PET scanning begins with the injection of a radiolabeled tracer that binds preferentially to the target protein; tracer molecules are then continuously delivered to the brain via the bloodstream. By detecting the radioactive decay of the tracer over time, dynamic PET data are constructed to reflect the concentration of the target protein in the brain at each time. The fundamental problem in the analysis of dynamic PET data involves estimating the impulse response function (IRF), which is necessary for describing the binding behavior of the injected radiotracer. Virtually all existing methods have three common aspects: summarizing the entire IRF with a single scalar measure; modeling each subject separately; and the imposition of parametric restrictions on the IRF. In contrast, we propose a functional data analytic approach that regards each subject's IRF as the basic analysis unit, models multiple subjects simultaneously, and estimates the IRF nonparametrically. We pose our model as a linear mixed effect model in which population level fixed effects and subject-specific random effects are expanded using a B-spline basis. Shrinkage and roughness penalties are incorporated in the model to enforce identifiability and smoothness of the estimated curves, respectively, while monotonicity and nonnegativity constraints impose biological information on estimates. We illustrate this approach by applying it to clinical PET data with subjects belonging to three diagnosic groups. We explore differences among groups by means of pointwise confidence intervals of the estimated mean curves based on bootstrap samples. Supplementary materials for this article are available online.
引用
收藏
页码:595 / 609
页数:15
相关论文
共 50 条
  • [41] Functional data analysis view of functional near infrared spectroscopy data
    Barati, Zeinab
    Zakeri, Issa
    Pourrezaei, Kambiz
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (11)
  • [42] Introduction to the analysis of PET data in oncology
    Giampaolo Tomasi
    Eric O. Aboagye
    [J]. Journal of Pharmacokinetics and Pharmacodynamics, 2013, 40 : 419 - 436
  • [43] PET data analysis of pulmonary abnormalities
    Keyes, JW
    [J]. RADIOLOGY, 1997, 204 (01) : 282 - 283
  • [44] Introduction to the analysis of PET data in oncology
    Tomasi, Giampaolo
    Aboagye, Eric O.
    [J]. JOURNAL OF PHARMACOKINETICS AND PHARMACODYNAMICS, 2013, 40 (04) : 419 - 436
  • [45] Fundamentals of quantitative PET data analysis
    Willemsen, ATM
    van den Hoff, J
    [J]. CURRENT PHARMACEUTICAL DESIGN, 2002, 8 (16) : 1513 - 1526
  • [46] Spectral analysis of PET projection data
    Meikle, SR
    Matthews, JC
    Cunningham, VJ
    Bailey, DL
    Livieratos, L
    Jones, T
    Price, P
    [J]. 1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1888 - 1892
  • [47] Modified dynamic data acquisition protocols for PET and FDG
    Strauss, Ludwig
    Pan, Leyun
    Haberkorn, Uwe
    Dimitrakopoulou-Strauss, Antonia
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [48] Investigation of lesion detectability in dynamic PET data sets
    Wang, Guobao
    Qi, Jinyi
    [J]. 2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 1344 - +
  • [49] Motion Compensation Based on Dynamic Data in PET Acquisition
    He, Jianfeng
    O'Keefe, Graeme J.
    Ackerly, Trevor
    Sun, Hua
    Geso, Moshi
    [J]. 2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 389 - 392
  • [50] Analysis and interpretation of dynamic FDG PET oncological studies using data reduction techniques
    Sotiris Pavlopoulos
    Trias Thireou
    George Kontaxakis
    Andres Santos
    [J]. BioMedical Engineering OnLine, 6