Biomechanical analysis of lumbar spine with interbody fusion surgery and U-shaped lumbar interspinous spacers

被引:4
|
作者
Yin, Jia-Yu [1 ]
Guo, Li-Xin [1 ]
机构
[1] Northeastern Univ, Sch Mech Engn & Automat, Shenyang, Peoples R China
基金
中国国家自然科学基金;
关键词
Lumbar interspinous spacers; interbody fusion surgery; coflex; finite element; whole-body vibration; implant; FINITE-ELEMENT MODEL; INTERVERTEBRAL DISC; IN-VITRO; FOLLOWER; LOAD; INSTABILITY; VIBRATION; SEGMENTS; INTACT; COFLEX;
D O I
10.1080/10255842.2020.1851368
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Previous research indicates whole-body vibration may lead to low back pain. The aim of this study is assessing the dynamic characteristics of a lumbar spine with Coflex and Coflex-F (commercial implants used as lumbar interspinous spacers) and effect of lumbar interbody fusion surgery. A transient dynamic analysis is performed on three numerical lumbar spine models under the loading condition of a vertical sinusoidal force of +/- 40 N with a compressive follower preload of 400 N. Also, Coflex-F model with and without interbody fusion surgery is analyzed under the same loading condition. The results show that the maximum value and vibration amplitude of von Mises stress in annulus ground substance (AGS) and intradiscal pressure (IDP) at implanted segment decrease from healthy model to Coflex model, and Coflex-F model. By contrast, for adjacent segments the maximum value of implanted models are larger than that of healthy model. The maximum value of endplates with and without cage are 2.44 MPa and 1.73 MPa (L4 inferior endplate), 1.94 MPa and 1.42 MPa (L5 superior endplate), respectively. The vibration amplitude of Coflex-F model with fusion surgery is smaller than that without fusion surgery. Coflex and Coflex-F not only protect implanted segment but also have a negative effect on adjacent segments. Inserting cage for Coflex-F model can absorb vibration energy at adjacent segments.
引用
收藏
页码:788 / 798
页数:11
相关论文
共 50 条
  • [31] Management of Infected Transforaminal Lumbar Interbody Fusion Cage in Posterior Degenerative Lumbar Spine Surgery
    Chang, Chia-Wei
    Fu, Tsai-Sheng
    Chen, Wen-Jer
    Chen, Chien-Wen
    Lai, Po-Liang
    Chen, Shih-Hao
    WORLD NEUROSURGERY, 2019, 126 : E330 - E341
  • [32] Surgical outcomes of anterior lumbar interbody fusion in revision lumbar interbody fusion surgery
    Shih, Cheng-Min
    Hsu, Cheng-En
    Chen, Kun-Hui
    Pan, Chien-Chou
    Lee, Cheng-Hung
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [33] Biomechanical changes of oblique lumbar interbody fusion with different fixation techniques in degenerative spondylolisthesis lumbar spine: a finite element analysis
    Tao, Er-Xu
    Zhang, Ren-Jie
    Zhang, Bo
    Wang, Jia-Qi
    Zhou, Lu-Ping
    Shen, Cai-Liang
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [34] Biomechanical and clinical studies on lumbar spine fusion surgery: a review
    Kishore Pradeep
    Bidyut Pal
    Medical & Biological Engineering & Computing, 2023, 61 : 617 - 634
  • [35] Biomechanical and clinical studies on lumbar spine fusion surgery: a review
    Pradeep, Kishore
    Pal, Bidyut
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2023, 61 (03) : 617 - 634
  • [36] Biomechanical Comparison of the Influence of Osteoporosis on the Lumbar Spine After Lumbar Interbody Fusion Surgery or Non-fusion Dynamic Stabilization Surgery Under Whole Body Vibration
    Fan, Wei
    Zhang, Chi
    Zhang, Dong-Xiang
    Wang, Qing-Dong
    Guo, Li-Xin
    IRBM, 2023, 44 (05)
  • [37] Biomechanical comparison of the effects of anterior, posterior and transforaminal lumbar interbody fusion on vibration characteristics of the human lumbar spine
    Fan, Wei
    Guo, Li-Xin
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2019, 22 (05) : 490 - 498
  • [38] Stress analysis of the disc adjacent to interbody fusion in lumbar spine
    Chen, CS
    Cheng, CK
    Liu, CL
    Lo, WH
    MEDICAL ENGINEERING & PHYSICS, 2001, 23 (07) : 483 - 491
  • [39] ANTERIOR INTERBODY LUMBAR SPINE FUSION FOR SPONDYLOLISTHESIS
    SORENSEN, KH
    ACTA ORTHOPAEDICA SCANDINAVICA, 1983, 54 (05): : 781 - 781
  • [40] Biomechanical comparison of posterior lumbar interbody fusion and transforaminal lumbar interbody fusion performed at 1 and 2 levels
    Ames, CP
    Acosta, FL
    Chi, J
    Iyengar, J
    Muiru, W
    Acaroglu, E
    Puttlitz, CM
    SPINE, 2005, 30 (19) : E562 - E566