Biomechanical Comparison of the Influence of Osteoporosis on the Lumbar Spine After Lumbar Interbody Fusion Surgery or Non-fusion Dynamic Stabilization Surgery Under Whole Body Vibration

被引:0
|
作者
Fan, Wei [1 ]
Zhang, Chi [1 ]
Zhang, Dong-Xiang [1 ]
Wang, Qing-Dong [2 ]
Guo, Li-Xin [1 ]
机构
[1] Northeastern Univ, Sch Mech Engn & Automat, Shenyang, Peoples R China
[2] Tsinghua Univ, Dept Mech Engn, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
Biomechanics; Lumbar spine; Interbody fusion; Non-fusion dynamic stabilization; Osteoporosis; Whole body vibration; ADJACENT; MODEL; LOAD;
D O I
10.1016/j.irbm.2023.100797
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: The objective of this study was to determine and compare the influence of osteoporosis on biomechanics of the spine after lumbar interbody fusion (LIF) surgery or non-fusion dynamic stabilization (NFDS) surgery under whole body vibration (WBV) which is typically present in moving vehicles.Methods: Based on a previously validated finite element (FE) model of normal human lumbosacral spine, four surgical models including LIF, LIF with osteoporosis (LIF-OST), NFDS, and NFDS with osteoporosis (NFDS-OST) were constructed. Biomechanical responses of the surgical models to an axial cyclic load were calculated using transient dynamic analysis. Response parameters include vibration amplitudes of the endplate stress and screw stress at surgical L4-L5 level, vibration amplitudes of the disc bulge and intradiscal pressure at adjacent L3-L4 level.Results: Osteoporosis increased vibration amplitudes of all these investigated response parameters. Further, we found that vibration amplitudes of the endplate stress and screw stress for the LIF-OST model were significantly higher than those for the NFDS-OST model, but there was very small difference in vibration amplitudes of the disc bulge and intradiscal pressure between the LIF-OST and NFDS-OST models.Conclusions: For both the LIF and NFDS surgeries, osteoporosis might increase the risk for implant failure and accelerate adjacent segment degeneration (ASD) under WBV. When osteoporosis occurs, LIF might be associated with a higher likelihood of implant failure at the surgical level compared with NFDS, and the surgical approach (LIF or NFDS) might have little influence on biomechanics of the adjacent level.& COPY; 2023 AGBM. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] The effect of non-fusion dynamic stabilization on biomechanical responses of the implanted lumbar spine during whole-body vibration
    Fan, Wei
    Guo, Li-Xin
    [J]. Computer Methods and Programs in Biomedicine, 2020, 192
  • [2] Biomechanical role of osteoporosis in the vibration characteristics of human spine after lumbar interbody fusion
    Wang, Qing-Dong
    Guo, Li-Xin
    [J]. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2020, 36 (12)
  • [3] Anterior approaches to the lumbar spine in non-fusion surgery
    Weisskopf, M
    Ohnsorge, JAK
    Gravius, S
    Niethard, FU
    [J]. EUROPEAN SPINE JOURNAL, 2005, 14 (07) : 11 - 12
  • [4] The effect of non -fusion dynamic stabilization on biomechanical responses of the implanted lumbar spine during whole -body vibration
    Fan, Wei
    Guo, Li-Xin
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2020, 192
  • [5] Reoperation rate after fusion and non-fusion surgery for degenerative lumbar spine disease
    Baranowska-Kijewska, Joanna
    Baranowski, Pawel
    Baranowska, Alicja
    Jarzynski, Tobiasz
    Rybarczyk, Marek
    [J]. ARCHIVES OF MEDICAL SCIENCE, 2023, 19 (04) : 1154 - 1161
  • [6] Clinical Experiences of Non-fusion Dynamic Stabilization Surgery for Adjacent Segmental Pathology after Lumbar Fusion
    Lee, Soo Eon
    Jahng, Tae-Ahn
    Kim, Hyun-Jib
    [J]. INTERNATIONAL JOURNAL OF SPINE SURGERY, 2016, 10
  • [7] Kinematic evaluation of the adjacent segments after lumbar instrumented surgery: a comparison between rigid fusion and dynamic non-fusion stabilization
    Yuichiro Morishita
    Hideki Ohta
    Masatoshi Naito
    Yoshiyuki Matsumoto
    George Huang
    Masato Tatsumi
    Yoshiharu Takemitsu
    Hirotaka Kida
    [J]. European Spine Journal, 2011, 20 : 1480 - 1485
  • [8] Kinematic evaluation of the adjacent segments after lumbar instrumented surgery: a comparison between rigid fusion and dynamic non-fusion stabilization
    Morishita, Yuichiro
    Ohta, Hideki
    Naito, Masatoshi
    Matsumoto, Yoshiyuki
    Huang, George
    Tatsumi, Masato
    Takemitsu, Yoshiharu
    Kida, Hirotaka
    [J]. EUROPEAN SPINE JOURNAL, 2011, 20 (09) : 1480 - 1485
  • [9] Prediction of the influence of vertical whole-body vibration on biomechanics of spinal segments after lumbar interbody fusion surgery
    Fan, Wei
    Guo, Li-Xin
    [J]. CLINICAL BIOMECHANICS, 2021, 86
  • [10] Biomechanical evaluation of a posterior non-fusion instrumentation of the lumbar spine
    Schmoelz, Werner
    Erhart, Stefanie
    Unger, Stefan
    Disch, Alexander C.
    [J]. EUROPEAN SPINE JOURNAL, 2012, 21 (05) : 939 - 945