A pilot study to assess the feasibility of measurement of adrenal gland volume by magnetic resonance imaging

被引:11
|
作者
Grant, Lee A. [1 ]
Napolitano, Antonella [2 ]
Miller, Sam [3 ]
Stephens, Kimberley [4 ]
McHugh, Simon M. [2 ]
Dixon, Adrian K. [1 ]
机构
[1] Univ Cambridge, Teaching Hosp, NHS Fdn Trust, Dept Radiol, Cambridge, England
[2] Addenbrookes Hosp, Addenbrookes Ctr Clin Invest, Clin Unit Cambridge, GlaxoSmithKline R&D, Cambridge, England
[3] GlaxoSmithKline Res & Dev Ltd, Anal Applicat Res Grp, Harlow, Essex, England
[4] GlaxoSmithKline Res & Dev Ltd, Discovery Stat, Harlow, Essex, England
关键词
FAT; TOMOGRAPHY; MRI;
D O I
10.3109/02841850903352620
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine whether MR imaging could be used to measure adrenal volume, and to determine the intra- and interobserver variation and repeatability of MR volume imaging of adrenals in healthy human subjects. Material and Methods: This was a single-cohort, sequential design, three-part study involving four MRI examinations per subject following ethical approval and informed consent. Information was collected on four healthy subjects (three male and one female). Two different investigators estimated the area of the adrenal gland for each of the 3-mm contiguous slices (and consequently adrenal volume). In order to estimate inter- and intrareader variability, a repeated-measures mixed model was fitted with adrenal volume as the dependent variable. In order to estimate any bias between readers, Bland-Altman methodology was applied. Results: Intraobserver variation for adrenal gland volume is approximately 5% of a 3-cm<SU3 </SUadrenal gland. Interobserver variation is approximately 9% of a 3-cm<SU3</SU adrenal gland. Potential variation in measurement for adrenal volume from all sources equates to approximately 14% of a 3-cm<SU3</SU adrenal gland. Verification of image reading by a second investigator (consensus reading) reduces variability. Conclusion: Analysis of adrenal gland volume using MRI is a potentially reliable technique that could be used to assess a pathological change in adrenal size.
引用
收藏
页码:117 / 120
页数:4
相关论文
共 50 条
  • [31] Alveolar hydatid disease of the adrenal gland: computed tomography and magnetic resonance imaging findings
    Tamotsu Kamishima
    Toru Harabayashi
    Syuhei Ishikawa
    Kanako C. Kubota
    Katsuya Nonomura
    Tokuhiko Omatsu
    Yuya Onodera
    Hiroki Shirato
    Satoshi Terae
    Japanese Journal of Radiology, 2009, 27 : 225 - 228
  • [32] Obesity and pituitary gland volume - a correlation study using three-dimensional magnetic resonance imaging
    Fehrenbach, Uli
    Jadan, Anas
    Auer, Timo A.
    Kreutz, Katharina
    Geisel, Dominik
    Ziagaki, Athanasia
    Bobbert, Thomas
    Wiener, Edzard
    NEURORADIOLOGY JOURNAL, 2020, 33 (05): : 400 - 409
  • [33] Assesment of the Effect of Age and Gender on Pituitary Gland Volume by Magnetic Resonance Imaging
    Unlu, Ebru
    Turamanlar, Ozan
    Beker-Acay, Mehtap
    Yildiz, Yunus
    Acay, Akif
    Kacar, Emre
    Balcik, Cinar
    Horata, Erdal
    JOURNAL OF CLINICAL AND ANALYTICAL MEDICINE, 2015, 6 : 434 - 437
  • [34] Magnetic resonance imaging (MRI) of bruises: a pilot study
    Neil E. I. Langlois
    Claire G. Ross
    Roger W. Byard
    Forensic Science, Medicine, and Pathology, 2013, 9 : 363 - 366
  • [35] Magnetic resonance imaging (MRI) of bruises: a pilot study
    Langlois, Neil E. I.
    Ross, Claire G.
    Byard, Roger W.
    FORENSIC SCIENCE MEDICINE AND PATHOLOGY, 2013, 9 (03) : 363 - 366
  • [36] MAGNETIC-RESONANCE-IMAGING OF THE ADRENAL-GLAND IN WOMEN WITH LATE-ONSET ADRENAL-HYPERPLASIA
    AZZIZ, R
    KENNEY, PJ
    FERTILITY AND STERILITY, 1991, 56 (01) : 142 - 144
  • [37] MAGNETIC-RESONANCE IMAGING OF THE ADRENAL
    BYDDER, GM
    CLINICAL RADIOLOGY, 1988, 39 (05) : 568 - 568
  • [38] Magnetic resonance imaging of adrenal angiomyolipoma
    Elsayes, KM
    Narra, VR
    Lewis, JS
    Brown, JJ
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2005, 29 (01) : 80 - 82
  • [39] MAGNETIC-RESONANCE-IMAGING OF THE ADRENAL
    REINIG, JW
    DOPPMAN, JL
    RADIOLOGE, 1986, 26 (04): : 186 - 190
  • [40] Volume of components of labyrinth: Magnetic resonance imaging study
    Kendi, TK
    Arikan, OK
    Koc, C
    OTOLOGY & NEUROTOLOGY, 2005, 26 (04) : 778 - 781