A pilot study to assess the feasibility of measurement of adrenal gland volume by magnetic resonance imaging

被引:11
|
作者
Grant, Lee A. [1 ]
Napolitano, Antonella [2 ]
Miller, Sam [3 ]
Stephens, Kimberley [4 ]
McHugh, Simon M. [2 ]
Dixon, Adrian K. [1 ]
机构
[1] Univ Cambridge, Teaching Hosp, NHS Fdn Trust, Dept Radiol, Cambridge, England
[2] Addenbrookes Hosp, Addenbrookes Ctr Clin Invest, Clin Unit Cambridge, GlaxoSmithKline R&D, Cambridge, England
[3] GlaxoSmithKline Res & Dev Ltd, Anal Applicat Res Grp, Harlow, Essex, England
[4] GlaxoSmithKline Res & Dev Ltd, Discovery Stat, Harlow, Essex, England
关键词
FAT; TOMOGRAPHY; MRI;
D O I
10.3109/02841850903352620
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine whether MR imaging could be used to measure adrenal volume, and to determine the intra- and interobserver variation and repeatability of MR volume imaging of adrenals in healthy human subjects. Material and Methods: This was a single-cohort, sequential design, three-part study involving four MRI examinations per subject following ethical approval and informed consent. Information was collected on four healthy subjects (three male and one female). Two different investigators estimated the area of the adrenal gland for each of the 3-mm contiguous slices (and consequently adrenal volume). In order to estimate inter- and intrareader variability, a repeated-measures mixed model was fitted with adrenal volume as the dependent variable. In order to estimate any bias between readers, Bland-Altman methodology was applied. Results: Intraobserver variation for adrenal gland volume is approximately 5% of a 3-cm<SU3 </SUadrenal gland. Interobserver variation is approximately 9% of a 3-cm<SU3</SU adrenal gland. Potential variation in measurement for adrenal volume from all sources equates to approximately 14% of a 3-cm<SU3</SU adrenal gland. Verification of image reading by a second investigator (consensus reading) reduces variability. Conclusion: Analysis of adrenal gland volume using MRI is a potentially reliable technique that could be used to assess a pathological change in adrenal size.
引用
收藏
页码:117 / 120
页数:4
相关论文
共 50 条
  • [21] Feasibility of multimodal magnetic resonance imaging to assess maternal hyperoxygenation in sheep pregnancy
    Flouri, Dimitra
    Darby, Jack R. T.
    Holman, Stacey L.
    Williams, Georgia
    Vavourakis, Vasileios
    David, Anna L.
    Morrison, Janna L.
    Melbourne, Andrew
    JOURNAL OF PHYSIOLOGY-LONDON, 2025, 603 (05): : 1029 - 1044
  • [22] Volume measurement of horizontal extraocular muscles with magnetic resonance imaging
    Nishida, Y
    Aoki, Y
    Hayashi, O
    Murata, T
    Nishida, E
    Kani, K
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 1996, 40 (03) : 439 - 446
  • [23] MEASUREMENT OF BREAST IMPLANT VOLUME WITH MAGNETIC-RESONANCE-IMAGING
    MINEYEV, M
    KRAMER, D
    KAUFMAN, L
    CARLSON, J
    FRANKEL, S
    ANNALS OF PLASTIC SURGERY, 1995, 34 (04) : 348 - 351
  • [24] Measurement of frontal lobe volume on magnetic resonance imaging scans
    Aylward, EH
    Augustine, A
    Li, Q
    Barta, PE
    Pearlson, GD
    PSYCHIATRY RESEARCH-NEUROIMAGING, 1997, 75 (01) : 23 - 30
  • [25] Comparison of Methods to Assess Quadriceps Muscle Volume Using Magnetic Resonance Imaging
    Nordez, Antoine
    Jolivet, Erwan
    Suedhoff, Ingrid
    Bonneau, Dominique
    de Guise, Jacques A.
    Skalli, Wafa
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (05) : 1116 - 1123
  • [26] Magnetic resonance imaging measurement of volume magnetic susceptibility using a boundary condition
    Wang, ZYJ
    Li, SC
    Haselgrove, JC
    JOURNAL OF MAGNETIC RESONANCE, 1999, 140 (02) : 477 - 481
  • [27] Alveolar hydatid disease of the adrenal gland: computed tomography and magnetic resonance imaging findings
    Kamishima, Tamotsu
    Harabayashi, Toru
    Ishikawa, Syuhei
    Kubota, Kanako C.
    Nonomura, Katsuya
    Omatsu, Tokuhiko
    Onodera, Yuya
    Shirato, Hiroki
    Terae, Satoshi
    JAPANESE JOURNAL OF RADIOLOGY, 2009, 27 (05) : 225 - 228
  • [28] NUCLEAR MAGNETIC-RESONANCE IMAGING OF THE ADRENAL-GLAND - A PRELIMINARY-REPORT
    MOON, KL
    HRICAK, H
    CROOKS, LE
    GOODING, CA
    MOSS, AA
    ENGELSTAD, BL
    KAUFMAN, L
    RADIOLOGY, 1983, 147 (01) : 155 - 160
  • [29] Comparison of three methods for the estimation of the pituitary gland volume using magnetic resonance imaging: a stereological study
    Ertekin, Tolga
    Acer, Niyazi
    Turgut, Ahmet T.
    Aycan, Kenan
    Ozcelik, Ozlem
    Turgut, Mehmet
    PITUITARY, 2011, 14 (01) : 31 - 38
  • [30] Comparison of three methods for the estimation of the pituitary gland volume using magnetic resonance imaging: a stereological study
    Tolga Ertekin
    Niyazi Acer
    Ahmet T. Turgut
    Kenan Aycan
    Özlem Özçelik
    Mehmet Turgut
    Pituitary, 2011, 14 : 31 - 38