A pilot study to assess the feasibility of measurement of adrenal gland volume by magnetic resonance imaging

被引:11
|
作者
Grant, Lee A. [1 ]
Napolitano, Antonella [2 ]
Miller, Sam [3 ]
Stephens, Kimberley [4 ]
McHugh, Simon M. [2 ]
Dixon, Adrian K. [1 ]
机构
[1] Univ Cambridge, Teaching Hosp, NHS Fdn Trust, Dept Radiol, Cambridge, England
[2] Addenbrookes Hosp, Addenbrookes Ctr Clin Invest, Clin Unit Cambridge, GlaxoSmithKline R&D, Cambridge, England
[3] GlaxoSmithKline Res & Dev Ltd, Anal Applicat Res Grp, Harlow, Essex, England
[4] GlaxoSmithKline Res & Dev Ltd, Discovery Stat, Harlow, Essex, England
关键词
FAT; TOMOGRAPHY; MRI;
D O I
10.3109/02841850903352620
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine whether MR imaging could be used to measure adrenal volume, and to determine the intra- and interobserver variation and repeatability of MR volume imaging of adrenals in healthy human subjects. Material and Methods: This was a single-cohort, sequential design, three-part study involving four MRI examinations per subject following ethical approval and informed consent. Information was collected on four healthy subjects (three male and one female). Two different investigators estimated the area of the adrenal gland for each of the 3-mm contiguous slices (and consequently adrenal volume). In order to estimate inter- and intrareader variability, a repeated-measures mixed model was fitted with adrenal volume as the dependent variable. In order to estimate any bias between readers, Bland-Altman methodology was applied. Results: Intraobserver variation for adrenal gland volume is approximately 5% of a 3-cm<SU3 </SUadrenal gland. Interobserver variation is approximately 9% of a 3-cm<SU3</SU adrenal gland. Potential variation in measurement for adrenal volume from all sources equates to approximately 14% of a 3-cm<SU3</SU adrenal gland. Verification of image reading by a second investigator (consensus reading) reduces variability. Conclusion: Analysis of adrenal gland volume using MRI is a potentially reliable technique that could be used to assess a pathological change in adrenal size.
引用
收藏
页码:117 / 120
页数:4
相关论文
共 50 条
  • [1] Feasibility of tissue magnetic resonance imaging - A pilot study in comparison with tissue Doppler imaging and invasive measurement
    Paelinck, BP
    de Roos, A
    Bax, JJ
    Bosmans, JM
    van Der Geest, RJ
    Dhondt, D
    Parizel, PM
    Vrints, CJ
    Lamb, HJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (07) : 1109 - 1116
  • [2] Adrenal gland volume measurement in septic shock and control patients: a pilot study
    Stephanie Nougaret
    B. Jung
    S. Aufort
    G. Chanques
    S. Jaber
    B. Gallix
    European Radiology, 2010, 20 : 2348 - 2357
  • [3] Adrenal gland volume measurement in septic shock and control patients: a pilot study
    Nougaret, Stephanie
    Jung, B.
    Aufort, S.
    Chanques, G.
    Jaber, S.
    Gallix, B.
    EUROPEAN RADIOLOGY, 2010, 20 (10) : 2348 - 2357
  • [4] Adrenal gland volume assessed by magnetic resonance imaging in women with polycystic ovary syndrome
    Unlu, E.
    Unlu, B. S.
    Yildiz, Y.
    Beker-Acay, M.
    Kacar, E.
    Turamanlar, O.
    Tulmac, O. B.
    Seven, A.
    Ozuguz, U.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2016, 97 (01) : 57 - 63
  • [5] Magnetic resonance imaging of adrenal gland: state of the art
    d'Amuri, Fabiano Vito
    Maestroni, Umberto
    Pagnini, Francesco
    Russo, Umberto
    Melani, Elisa
    Ziglioli, Francesco
    Negrini, Giulio
    Cella, Simone
    Cappabianca, Salvatore
    Reginelli, Alfonso
    Barile, Antonio
    De Filippo, Massimo
    GLAND SURGERY, 2019, 8 : S223 - S232
  • [6] MAGNETIC-RESONANCE-IMAGING OF THE ADRENAL-GLAND
    BOLLAND, GW
    LEE, MJ
    CRITICAL REVIEWS IN DIAGNOSTIC IMAGING, 1995, 36 (02) : 115 - 174
  • [7] MAGNETIC-RESONANCE-IMAGING OF THE ADRENAL-GLAND AND KIDNEY
    BROWN, ED
    SEMELKA, RC
    TOPICS IN MAGNETIC RESONANCE IMAGING, 1995, 7 (02) : 90 - 101
  • [8] A Pilot Study of Dynamic Magnetic Resonance Dacryocystography Imaging to Assess Functional Epiphora
    Macri, Carmelo Zak
    Shapira, Yinon
    Tong, Jessica
    Hood, Kylie
    Drivas, Peter
    Patel, Sandy
    Selva, Dinesh
    SEMINARS IN OPHTHALMOLOGY, 2024, 39 (02) : 158 - 164
  • [9] Magnetic resonance imaging study of pineal gland volume and positive symptoms in schizophrenia
    Bersani, G
    Garavini, A
    Iannitelli, A
    Nordio, M
    Di Biasi, C
    Trasimeni, G
    Pancheri, P
    SCHIZOPHRENIA RESEARCH, 2000, 41 (01) : 120 - 121
  • [10] Magnetic resonance imaging measurement of knee cartilage volume in a multicentre study
    Morgan, SR
    Waterton, JC
    Maciewicz, RA
    Leadbetter, JE
    Gandy, SJ
    Moots, RJ
    Creamer, P
    Nash, AFP
    RHEUMATOLOGY, 2004, 43 (01) : 19 - 21