Ruthenium Oxide Hexacyanoferrate as an Effective Electrode Modifier for Amperometric Detection of Iodate and Hydrogen Peroxide

被引:1
|
作者
Dodevska, Totka [1 ]
Shterev, Ivan [1 ]
Lazarova, Yanna [1 ]
Hadzhiev, Dobrin [1 ]
机构
[1] Univ Food Technol, Dept Organ Chem & Inorgan Chem, 26 Maritsa Blvd, Plovdiv 4002, Bulgaria
关键词
Ruthenium oxide hexacyanoferrate; sensor; iodate; hydrogen peroxide; GLASSY-CARBON ELECTRODE; ELECTROCATALYTIC REDUCTION; ASCORBIC-ACID; ELECTROCHEMICAL SYNTHESIS; GRAPHITE-ELECTRODES; PASTE ELECTRODE; SENSOR; FILM; NANOPARTICLES; NANOTUBES;
D O I
10.17344/acsi.2020.6111
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Ruthenium oxide hexacyanoferrate (RuOHCF) film was electrochemically deposited onto a glassy carbon (GC) surface using consecutive cyclic voltammetry as a facile and green synthetic strategy. The electrochemical behaviour and electrocatalytic properties of the modified electrode RuOHCF/GC were evaluated with regards to electroreduction of hydrogen peroxide and iodate in a strong acidic medium (pHs 1.0-2.0) by using different electrochemical techniques, including cyclic voltammetry and amperometry at a constant potential. Electrochemical studies indicated that RuOHCF/GC possess a high catalytic activity in both studied reactions, fast response and good reproducibility of the current signal. The RuOHCF/GC exhibits enhanced electrocatalytic behaviour compared with other modified electrodes reported before. The simple and reproducible procedure for electrode fabrication, the wide linear range, anti-interference performance and long-time stability of the RuOHCF/GC make it a promising sensing material for practical quantitative determination of hydrogen peroxide and iodate. Remarkably, the reported modified electrode provided superior sensitive (1050 mu A mM(-1) cm(-2)) and highly selective amperometric detection of iodate.
引用
收藏
页码:1216 / 1226
页数:11
相关论文
共 50 条
  • [31] INDIUM-TIN OXIDE FILM ELECTRODE AS CATALYTIC AMPEROMETRIC SENSOR FOR HYDROGEN-PEROXIDE
    CAI, XH
    OGOREVC, B
    TAVCAR, G
    WANG, J
    ANALYST, 1995, 120 (10) : 2579 - 2583
  • [32] Poly(Celestine Blue)-Graphene Oxide Nanohybrid Modified Electrode for Amperometric Determination of Hydrogen Peroxide
    Sangeetha, N. S.
    Ramaprabhu, Sundara
    Narayanan, S. Sriman
    GRAPHENE, 2013, 1 (02) : 136 - 141
  • [33] AMPEROMETRIC DETECTION OF NONELECTROACTIVE CATIONS IN FLOW SYSTEMS AT A CUPRIC HEXACYANOFERRATE ELECTRODE
    THOMSEN, KN
    BALDWIN, RP
    ANALYTICAL CHEMISTRY, 1989, 61 (23) : 2594 - 2598
  • [34] Non enzymatic hydrogen peroxide detection at ruthenium oxide-gold nano particle-Nafion modified electrode
    Anjalidevi, C.
    Dharuman, V.
    Narayanan, J. Shankara
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 182 : 256 - 263
  • [35] NEW CATALYTIC ELECTRODE FOR THE AMPEROMETRIC DETERMINATION OF HYDROGEN-PEROXIDE
    IWASE, A
    KUDO, S
    TANAKA, N
    ANALYTICA CHIMICA ACTA, 1979, 110 (01) : 157 - 160
  • [36] Dendrimer-rhodium nanoparticle modified glassy carbon electrode for amperometric detection of hydrogen peroxide
    Chandra, Sudeshna
    Lokesh, K. S.
    Nicolai, Anja
    Lang, Heinrich
    ANALYTICA CHIMICA ACTA, 2009, 632 (01) : 63 - 68
  • [38] Amperometric detection of hydrogen peroxide utilizing synergistic action of cobalt hexacyanoferrate and carbon nanotubes chemically modified with platinum nanoparticles
    Han, Lijuan
    Wang, Qiang
    Tricard, Simon
    Liu, Jianxin
    Fang, Jian
    Zhao, Jihua
    Shen, Weiguo
    RSC ADVANCES, 2013, 3 (01) : 281 - 287
  • [39] Amperometric Sensing of Hydrogen Peroxide Using Graphene Oxide-Alizarin Modified Glassy Carbon Electrode
    Muhammet, Sinan Mithat
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (06):
  • [40] Amperometric sensors for simultaneous superoxide and hydrogen peroxide detection
    Univ of Illinois, Urbana, United States
    Anal Chem, 3 (454-462):