Assessment of Repeatability, Reproducibility, and Performances of T2 Mapping-Based Radiomics Features: A Comparative Study

被引:14
|
作者
Crombe, Amandine [1 ,2 ,3 ]
Buy, Xavier [1 ]
Han, Fei [4 ]
Toupin, Solenn [5 ]
Kind, Michele [1 ]
机构
[1] Comprehens Canc Ctr Nouvelle Aquitaine, Inst Bergonie, Dept Oncol Imaging, Bordeaux, France
[2] Bordeaux Univ, Bordeaux, France
[3] INRIA Bordeaux Sud Ouest, Modelisat Oncol MOnc Team, CNRS, UMR 5251, Talence, France
[4] Siemens Med Solut USA, Los Angeles, CA USA
[5] Siemens Healthcare France, St Denis, France
关键词
magnetic resonance imaging; reproducibility of results; abdomen; volunteers; biomarkers; radiomics;
D O I
10.1002/jmri.27558
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Magnetic resonance imaging (MRI)-based radiomics features (RFs) quantify tumors radiological phenotypes but are sensitive to postprocessing parameters, including the intensity harmonization technique (IHT), while mappings enable objective quantitative assessment. Purpose To investigate whether T2 mapping could improve repeatability, reproducibility, and performances of radiomics compared to conventional T2-weighted imaging (T2WI). Study Type Prospective. Subjects Twenty-six healthy adults. Field Strength/Sequence Respiratory-trigged radial turbo spin echo (TSE) multiecho T2 mapping (prototype) and conventional TSE T2WI of the abdomen were acquired twice at 1.5 T. Assessment T2 maps were reconstructed using a two-parameter exponential fitting model. Volumes-of-interest (VOIs) were manually drawn in six tissues: liver, kidney, pancreas, muscle, bone, and spleen. After co-registration, conventional T2WIs were processed with two IHTs (standardization [std] and histogram-matching [HM]) resulting in four paired input image types: initial T2WI, T2WI(std), T2WI(HM), and T2-map. VOIs were propagated to extract 45 RFs from MRI-1 and MRI-2 of each image type (LIFEx, v5.10). Statistical Tests Influence of the input data type on RF values was evaluated with analysis of variance. RFs test-retest repeatability and reproducibility over multiple segmentations were evaluated with intra-class correlation coefficient (ICC). Correlations between k-means clusters and the six tissues depending on the RFs dataset were investigated with adjusted-Rand-index (ARI). Results About 41 of 45 (91.1%) RFs were significantly influenced by the input image type (P values < 0.05), which was the most influential factor on repeatability of RFs (P-value < 0.05). Repeatability ICCs from T2-map displayed intermediate values between the initial T2WI (range: 0.407-0.736) and the T2WI(HM) (range: 0.724-0.817). The number of RFs with interobserver and intraobserver reproducibility ICCs >= 0.90 was 37/45 (82.2%) for T2WI(HM), 33/45 (73.3%) for T2WI(std), 31/45 (68.9%) for T2 map, and 25/45 (55.6%) for the initial T2WI. T2 map provided the best tissue discrimination (ARI = 0.414 vs. 0.157 with T2WI(HM)). Data Conclusion T2 mapping provided RFs with moderate to substantial repeatability and reproducibility ICCs, along with the most preserved discriminative information. Level of Evidence 1 Technical Efficacy 1
引用
收藏
页码:537 / 548
页数:12
相关论文
共 50 条
  • [41] Assessment of ultrashort echo time (UTE) T2* mapping at 3T for the whole knee: repeatability, the effects of fat suppression, and knee position
    Wu, Zhenzhou
    Zaylor, William
    Sommer, Stefan
    Xie, Dongxing
    Zhong, Xiaodong
    Liu, Kecheng
    Kim, Jeehun
    Beveridge, Jillian E.
    Zhang, Xiaoliang
    Li, Xiaojuan
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (12) : 7893 - 7909
  • [42] T1ρ, T2 and T2* mapping of lumbar intervertebral disc degeneration: a comparison study
    Li Yang
    Cong Sun
    Tao Gong
    Quanlin Li
    Xin Chen
    Xinjuan Zhang
    BMC Musculoskeletal Disorders, 23
  • [43] Quantitative assessment of the supraspinatus tendon on MRI using T2/T2*mapping and shear-wave ultrasound elastography: a pilot study
    Krepkin, Konstantin
    Bruno, Mary
    Raya, Jose G.
    Adler, Ronald S.
    Gyftopoulos, Soterios
    SKELETAL RADIOLOGY, 2017, 46 (02) : 191 - 199
  • [44] Reproducibility of myocardial T1 and T2 relaxation time measurement using slice-interleaved T1 and T2 mapping sequences
    Bellm, Steven
    Basha, Tamer A.
    Shah, Ravi V.
    Murthy, Venkatesh L.
    Liew, Charlene
    Tang, Maxine
    Ngo, Long H.
    Manning, Warren J.
    Nezafat, Reza
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (05) : 1159 - 1167
  • [45] Reproducibility and Reliability of Quantitative and Weighted T1 and T2* Mapping for Myelin-Based Cortical Parcellation at 7 Tesla
    Haast, Roy A. M.
    Ivanov, Dimo
    Formisano, Elia
    Uludag, Kamil
    FRONTIERS IN NEUROANATOMY, 2016, 10
  • [46] In Vivo Repeatability and Multiscanner Reproducibility of MRI Radiomics Features in Patients With Monoclonal Plasma Cell Disorders A Prospective Bi-institutional Study
    Wennmann, Markus
    Bauer, Fabian
    Klein, Andre
    Chmelik, Jiri
    Groezinger, Martin
    Rotkopf, Lukas T. T.
    Neher, Peter
    Gnirs, Regula
    Kurz, Felix T. T.
    Nonnenmacher, Tobias
    Sauer, Sandra
    Weinhold, Niels
    Goldschmidt, Hartmut
    Kleesiek, Jens
    Bonekamp, David
    Weber, Tim F. F.
    Delorme, Stefan
    Maier-Hein, Klaus
    Schlemmer, Heinz-Peter
    Goetz, Michael
    INVESTIGATIVE RADIOLOGY, 2023, 58 (04) : 253 - 264
  • [47] Assessment of Reproducibility Of FDG-PET-Based Radiomics Features Across Scanners Using Phantom Imaging
    Fried, D.
    Meier, J.
    Mawlawi, O.
    Zhou, S.
    Ibbott, G.
    Liao, Z.
    Court, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3705 - 3706
  • [48] Myocardial T1rho mapping of patients with end-stage renal disease and its comparison with T1 mapping and T2 mapping: A feasibility and reproducibility study
    Wang, Lin
    Yuan, Jing
    Zhang, Shi-Jun
    Gao, Min
    Wang, Yuan-Cheng
    Wang, Yi-Xiang
    Ju, Shenghong
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (03) : 723 - 731
  • [49] Feasibility and reproducibility of T2 mapping and DWI for identifying malignant lymph nodes in rectal cancer
    Yu-xi Ge
    Shu-dong Hu
    Zi Wang
    Rong-ping Guan
    Xin-yi Zhou
    Qi-zhong Gao
    Gen Yan
    European Radiology, 2021, 31 : 3347 - 3354
  • [50] Quantitative MRI in the evaluation of articular cartilage health: reproducibility and variability with a focus on T2 mapping
    Surowiec, Rachel K.
    Lucas, Erin P.
    Ho, Charles P.