Assessment of Repeatability, Reproducibility, and Performances of T2 Mapping-Based Radiomics Features: A Comparative Study

被引:14
|
作者
Crombe, Amandine [1 ,2 ,3 ]
Buy, Xavier [1 ]
Han, Fei [4 ]
Toupin, Solenn [5 ]
Kind, Michele [1 ]
机构
[1] Comprehens Canc Ctr Nouvelle Aquitaine, Inst Bergonie, Dept Oncol Imaging, Bordeaux, France
[2] Bordeaux Univ, Bordeaux, France
[3] INRIA Bordeaux Sud Ouest, Modelisat Oncol MOnc Team, CNRS, UMR 5251, Talence, France
[4] Siemens Med Solut USA, Los Angeles, CA USA
[5] Siemens Healthcare France, St Denis, France
关键词
magnetic resonance imaging; reproducibility of results; abdomen; volunteers; biomarkers; radiomics;
D O I
10.1002/jmri.27558
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Magnetic resonance imaging (MRI)-based radiomics features (RFs) quantify tumors radiological phenotypes but are sensitive to postprocessing parameters, including the intensity harmonization technique (IHT), while mappings enable objective quantitative assessment. Purpose To investigate whether T2 mapping could improve repeatability, reproducibility, and performances of radiomics compared to conventional T2-weighted imaging (T2WI). Study Type Prospective. Subjects Twenty-six healthy adults. Field Strength/Sequence Respiratory-trigged radial turbo spin echo (TSE) multiecho T2 mapping (prototype) and conventional TSE T2WI of the abdomen were acquired twice at 1.5 T. Assessment T2 maps were reconstructed using a two-parameter exponential fitting model. Volumes-of-interest (VOIs) were manually drawn in six tissues: liver, kidney, pancreas, muscle, bone, and spleen. After co-registration, conventional T2WIs were processed with two IHTs (standardization [std] and histogram-matching [HM]) resulting in four paired input image types: initial T2WI, T2WI(std), T2WI(HM), and T2-map. VOIs were propagated to extract 45 RFs from MRI-1 and MRI-2 of each image type (LIFEx, v5.10). Statistical Tests Influence of the input data type on RF values was evaluated with analysis of variance. RFs test-retest repeatability and reproducibility over multiple segmentations were evaluated with intra-class correlation coefficient (ICC). Correlations between k-means clusters and the six tissues depending on the RFs dataset were investigated with adjusted-Rand-index (ARI). Results About 41 of 45 (91.1%) RFs were significantly influenced by the input image type (P values < 0.05), which was the most influential factor on repeatability of RFs (P-value < 0.05). Repeatability ICCs from T2-map displayed intermediate values between the initial T2WI (range: 0.407-0.736) and the T2WI(HM) (range: 0.724-0.817). The number of RFs with interobserver and intraobserver reproducibility ICCs >= 0.90 was 37/45 (82.2%) for T2WI(HM), 33/45 (73.3%) for T2WI(std), 31/45 (68.9%) for T2 map, and 25/45 (55.6%) for the initial T2WI. T2 map provided the best tissue discrimination (ARI = 0.414 vs. 0.157 with T2WI(HM)). Data Conclusion T2 mapping provided RFs with moderate to substantial repeatability and reproducibility ICCs, along with the most preserved discriminative information. Level of Evidence 1 Technical Efficacy 1
引用
收藏
页码:537 / 548
页数:12
相关论文
共 50 条
  • [31] Impact of motion correction on reproducibility and spatial variability of quantitative myocardial T2 mapping
    Sébastien Roujol
    Tamer A. Basha
    Sebastian Weingärtner
    Mehmet Akçakaya
    Sophie Berg
    Warren J. Manning
    Reza Nezafat
    Journal of Cardiovascular Magnetic Resonance, 17
  • [32] MR imaging assessment of myocardial edema with T2 mapping
    Montant, P.
    Sigovan, M.
    Revel, D.
    Douek, P.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2015, 96 (09) : 885 - 890
  • [33] T2 mapping for quantitative assessment of ankle cartilage of weightlifters
    Wu, Weibiao
    Kang, Zhuanzhuan
    Mu, Di
    Zhao, Huiyu
    Yang, Feng
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [34] T2 Mapping of the myocardium, a quantitative tool for assessment of myocarditis
    Darshit Thakrar
    Jeremy Collins
    Rahul Rustogi
    Aya Kino
    Sven Zuehlsdorff
    James Carr
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [35] T2 mapping for quantitative assessment of ankle cartilage of weightlifters
    Weibiao Wu
    Zhuanzhuan Kang
    Di Mu
    Huiyu Zhao
    Feng Yang
    Scientific Reports, 13
  • [36] Native T1 mapping-based radiomics diagnosis of kidney function and renal fibrosis in chronic kidney disease
    Wei, Chaogang
    Jin, Zhicheng
    Ma, Qing
    Xu, Yilin
    Zhu, Ye
    Zeng, Ying
    Zhang, Rui
    Zhang, Yueyue
    Jiang, Linsen
    Song, Kai
    Jiang, Zhen
    ISCIENCE, 2024, 27 (08)
  • [38] Comparative Analysis of Repeatability in CT Radiomics and Dosiomics Features under Image Perturbation: A Study in Cervical Cancer Patients
    Ma, Zongrui
    Zhang, Jiang
    Liu, Xi
    Teng, Xinzhi
    Huang, Yu-Hua
    Zhang, Xile
    Li, Jun
    Pan, Yuxi
    Sun, Jiachen
    Dong, Yanjing
    Li, Tian
    Chan, Lawrence Wing Chi
    Chang, Amy Tien Yee
    Siu, Steven Wai Kwan
    Cheung, Andy Lai-Yin
    Yang, Ruijie
    Cai, Jing
    CANCERS, 2024, 16 (16)
  • [39] T1ρ, T2 and T2*mapping of lumbar intervertebral disc degeneration: a comparison study
    Yang, Li
    Sun, Cong
    Gong, Tao
    Li, Quanlin
    Chen, Xin
    Zhang, Xinjuan
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [40] Quantitative assessment of the supraspinatus tendon on MRI using T2/T2* mapping and shear-wave ultrasound elastography: a pilot study
    Konstantin Krepkin
    Mary Bruno
    José G. Raya
    Ronald S. Adler
    Soterios Gyftopoulos
    Skeletal Radiology, 2017, 46 : 191 - 199