Optical correlation and convolution of real 2-D inputs and real 2-D filters

被引:0
|
作者
McAulay, AD [1 ]
机构
[1] Lehigh Univ, Bethlehem, PA 18015 USA
关键词
optical correlators; pattern recognition; Fourier optics; analog optical processing; signal processing;
D O I
10.1117/12.363955
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
Frequently in character recognition, there is a need to correlate or convolve purely real 2-D inputs and real 2-D filters. We propose two optical correlators. The first, basic real-input-real-filter optical correlator, adds x and y mirror images adjacent to the image to generate real and even images. This avoids the need for an offset reference to capture phase. Therefore, we have greater diffraction efficiency and a reduction in filter LCD pixel size. The second, Hilbert transform basic real-input-real-filter optical correlator, uses a Hilbert transform by masking in the filter plane to reduce the number elements in the filter LCD to that of the number of pixels in a filter image. An optical system can generate the mirror images in real time so that both the input LCD and the filter LCD can have only the same number of elements as their respective number of image pixels. Pile show how a spatial filter can be used to remove the intensity offset produced in the Hilbert transform and restore shift invariance if required. Finally, if desired, some rotation invariance can be achieved by overlapping the mirror images with the basic correlator. Advantages and disadvantages of the proposed correlators are discussed.
引用
收藏
页码:116 / 124
页数:9
相关论文
共 50 条
  • [21] Real-time hardware implementation of 2-D convolution-based image interpolation
    Zhang, Hui
    Hu, Guangshu
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2007, 47 (06): : 885 - 888
  • [22] OPTICAL IMPLEMENTATION OF THE 2-D HOPFIELD MODEL FOR A 2-D ASSOCIATIVE MEMORY
    LIN, SM
    LIU, LR
    WANG, ZJ
    OPTICS COMMUNICATIONS, 1989, 70 (02) : 87 - 91
  • [23] 2-D OR NOT 2-D - NO LONGER A QUESTION
    RITTER, SB
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1994, 11 (06): : 597 - 598
  • [24] Comparison Between 2-D Cross Correlation With 2-D Sub-Sampling and 2-D Tracking Using Beam Steering
    Azar, Reza Zahiri
    Goksel, Orcun
    Salcudean, Septimiu E.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (08) : 1534 - 1537
  • [25] Design of 2-D FIR filters with real and complex coefficients using two approximation criteria
    Wysocka-Schillak, Felicia
    INTERNATIONAL JOURNAL OF ELECTRONICS AND TELECOMMUNICATIONS, 2007, 53 (01) : 83 - 95
  • [26] FPGA Implementation of 2-D Wave Digital Filters for Real Time Motion Feature Extraction
    Kolonko, Lech
    Velten, Joerg
    Wagner, Daniel
    Kummert, Anton
    2017 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2017, : 2545 - 2548
  • [27] Image compression via 2-d real discrete chirplets
    Yang, J
    Zou, HX
    Vision '05: Proceedings of the 2005 International Conference on Computer Vision, 2005, : 107 - 109
  • [28] Metadata in sequential real-time 2-D detection
    Vihonen, Juho
    Ala-Kleemola, Timo
    Jylha, Juha
    Kerminen, Riitta
    Rauhamaa, Juhani
    IEEE SIGNAL PROCESSING LETTERS, 2007, 14 (06) : 413 - 416
  • [29] Parametric model for 2-D real scattering Schur polynomials
    Kummert, A
    ISCAS 2000: IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS - PROCEEDINGS, VOL II: EMERGING TECHNOLOGIES FOR THE 21ST CENTURY, 2000, : 212 - 215
  • [30] CORRELATION ENERGY OF 2-D ELECTRONS
    ISIHARA, A
    TOYODA, T
    ANNALS OF PHYSICS, 1977, 106 (02) : 394 - 406