Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries

被引:259
|
作者
Harold, KL [1 ]
Pollinger, H [1 ]
Matthews, BD [1 ]
Kercher, KW [1 ]
Sing, RF [1 ]
Heniford, BT [1 ]
机构
[1] Carolinas Med Ctr, Dept Surg, Charlotte, NC 28203 USA
关键词
electrosurgery; bipolar energy; ultrasonic shears;
D O I
10.1007/s00464-002-8833-7
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Advanced laparoscopic procedures have necessitated the development of new technology for vascular control. Suture ligation can be time-consuming and cumbersome during laparoscopic dissection. Titanium clips have been used for hemostasis, and recently plastic clips and energy sources such as ultrasonic coagulating shears and bipolar thermal energy devices have become popular. The purpose of this study was to compare the bursting pressure of arteries sealed with ultrasonic coagulating shears (UCS), electrothermal bipolar vessel sealer (EBVS), titanium laparoscopic clips (LCs), and plastic laparoscopic clips (PCs). In addition, the spread of thermal injury from the UCS and the EBVS was compared. Methods: Arteries in three size groups (2-3, 4-5 and 6-7 mm) were harvested from freshly euthanized pigs. Each of the four devices was used to seal 16 specimens from each size group for burst testing. A 5-Fr catheter was placed into the open end of the specimen and secured with a purse-string suture. The catheter was connected to a pressure monitor and saline was infused until there was leakage from the sealed end. This defined the bursting pressure in mmHg. The ultrasonic shears and bipolar thermal device were used to seal an additional 8 vessels in each size group, which were sent for histologic examination. These were examined with hematoxylin and eosin stains, and the extent of thermal injury, defined by coagulation necrosis, was measured in millimeters. Analysis of variance was performed and, where appropriate, a Tukey's test was also performed. Results: The EBVS's mean burst pressure was statistically higher than that of the UCS at 4 or 5 mm (601 vs 205 mmHg) and 6 or 7 mm (442 vs 175 mmHg). EBVS had higher burst pressures for the 4 or 5-mm group (601 mmHg) and 6 or 7-mm group (442 mmHg) compared with its pressure at 2 or 3 mm (128 mmHg) (p = 0.0001). The burst pressures of the UCS and EBVS at 2 or 3 mm were not significantly different. Both clips were statistically stronger than the thermal devices except at 4 or 5 mm, in which case the EBVS was as strong as the LC (601 vs 593 mmHg). The PC and LC were similar except at 4 or 5 mm, where the PC was superior (854 vs 593 mmHg). The PC burst pressure for 4 or 5 mm (854 mmHg) was statistically higher than that for vessels 2 or 3 mm (737 mmHg) but not different from the 6 or 7 mm pressure (767 mmHg). Thermal spread was not statistically different when comparing EBVS and UCS at any size (EBVS mean = 2.57 mm vs UCS mean = 2.18 mm). Conclusions: Both the PC and LC secured all vessel sizes to well above physiologic levels. The EBVS can be used confidently in vessels up to 7 mm. There is no difference in the thermal spread of the LigaSure vessel sealer and the UCS.
引用
收藏
页码:1228 / 1230
页数:3
相关论文
共 50 条
  • [31] Providing an Expert System to Manage Energy Consumption in Small- and Medium-Sized Industries Using Soft Computing
    Koravand, Iman
    Lotfi, Mohammad Reza
    Shayannia, Seyed Ahmad
    COMPLEXITY, 2022, 2022
  • [32] A comparison of endoscopic transtympanic myringoplasty and endoscopic type I tympanoplasty for repairing medium- to large-sized tympanic membrane perforation: a randomized clinical trial
    Viraporn Atchariyasathian
    Rata Suwannajak
    Yuvatiya Plodpai
    Pittayapon Pitathawatchai
    European Archives of Oto-Rhino-Laryngology, 2020, 277 : 2199 - 2207
  • [33] A comparison of endoscopic transtympanic myringoplasty and endoscopic type I tympanoplasty for repairing medium- to large-sized tympanic membrane perforation: a randomized clinical trial
    Atchariyasathian, Viraporn
    Suwannajak, Rata
    Plodpai, Yuvatiya
    Pitathawatchai, Pittayapon
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2020, 277 (08) : 2199 - 2207
  • [34] Effect of Hydrogen Peroxide and Superoxide Anions on Cytosolic Ca2+: Comparison of Endothelial Cells from Large-Sized and Small-Sized Arteries
    Sun, Lei
    Yau, Ho-Yan
    Lau, On-Chai
    Huang, Yu
    Yao, Xiaoqiang
    PLOS ONE, 2011, 6 (09):
  • [35] Introducing energy efficient technologies in small- and medium-sized enterprises in the apparel industry: A case study of Sri Lanka
    Pathirana, Shakila
    Yarime, Masaru
    JOURNAL OF CLEANER PRODUCTION, 2018, 178 : 247 - 257
  • [36] Techno-economic comparison of different thermal energy storage technologies for medium- scale CSP plants
    Petrollese, Mario
    Arena, Simone
    Cascetta, Mario
    Casti, Efisio
    Cau, Giorgio
    74TH ATI NATIONAL CONGRESS: ENERGY CONVERSION: RESEARCH, INNOVATION AND DEVELOPMENT FOR INDUSTRY AND TERRITORIES, 2019, 2191
  • [37] Exploring drivers for energy efficiency within small- and medium-sized enterprises: First evidences from Italian manufacturing enterprises
    Cagno, Enrico
    Trianni, Andrea
    APPLIED ENERGY, 2013, 104 : 276 - 285
  • [38] An integrated framework for elucidating the energy-saving decision-making process of Small- and medium-sized Enterprises in Taiwan
    Der-Fang Hung
    Chih-Ning Chu
    Energy Efficiency, 2020, 13 : 711 - 734
  • [39] An integrated framework for elucidating the energy-saving decision-making process of Small- and medium-sized Enterprises in Taiwan
    Hung, Der-Fang
    Chu, Chih-Ning
    ENERGY EFFICIENCY, 2020, 13 (04) : 711 - 734
  • [40] Analysis of the Most Effective Energy Efficiency Opportunities in Manufacturing Primary Metals, Plastics, and Textiles Small- and Medium-Sized Enterprises
    Cagno, Enrico
    Trianni, Andrea
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2012, 134 (02):