Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries

被引:259
|
作者
Harold, KL [1 ]
Pollinger, H [1 ]
Matthews, BD [1 ]
Kercher, KW [1 ]
Sing, RF [1 ]
Heniford, BT [1 ]
机构
[1] Carolinas Med Ctr, Dept Surg, Charlotte, NC 28203 USA
关键词
electrosurgery; bipolar energy; ultrasonic shears;
D O I
10.1007/s00464-002-8833-7
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Advanced laparoscopic procedures have necessitated the development of new technology for vascular control. Suture ligation can be time-consuming and cumbersome during laparoscopic dissection. Titanium clips have been used for hemostasis, and recently plastic clips and energy sources such as ultrasonic coagulating shears and bipolar thermal energy devices have become popular. The purpose of this study was to compare the bursting pressure of arteries sealed with ultrasonic coagulating shears (UCS), electrothermal bipolar vessel sealer (EBVS), titanium laparoscopic clips (LCs), and plastic laparoscopic clips (PCs). In addition, the spread of thermal injury from the UCS and the EBVS was compared. Methods: Arteries in three size groups (2-3, 4-5 and 6-7 mm) were harvested from freshly euthanized pigs. Each of the four devices was used to seal 16 specimens from each size group for burst testing. A 5-Fr catheter was placed into the open end of the specimen and secured with a purse-string suture. The catheter was connected to a pressure monitor and saline was infused until there was leakage from the sealed end. This defined the bursting pressure in mmHg. The ultrasonic shears and bipolar thermal device were used to seal an additional 8 vessels in each size group, which were sent for histologic examination. These were examined with hematoxylin and eosin stains, and the extent of thermal injury, defined by coagulation necrosis, was measured in millimeters. Analysis of variance was performed and, where appropriate, a Tukey's test was also performed. Results: The EBVS's mean burst pressure was statistically higher than that of the UCS at 4 or 5 mm (601 vs 205 mmHg) and 6 or 7 mm (442 vs 175 mmHg). EBVS had higher burst pressures for the 4 or 5-mm group (601 mmHg) and 6 or 7-mm group (442 mmHg) compared with its pressure at 2 or 3 mm (128 mmHg) (p = 0.0001). The burst pressures of the UCS and EBVS at 2 or 3 mm were not significantly different. Both clips were statistically stronger than the thermal devices except at 4 or 5 mm, in which case the EBVS was as strong as the LC (601 vs 593 mmHg). The PC and LC were similar except at 4 or 5 mm, where the PC was superior (854 vs 593 mmHg). The PC burst pressure for 4 or 5 mm (854 mmHg) was statistically higher than that for vessels 2 or 3 mm (737 mmHg) but not different from the 6 or 7 mm pressure (767 mmHg). Thermal spread was not statistically different when comparing EBVS and UCS at any size (EBVS mean = 2.57 mm vs UCS mean = 2.18 mm). Conclusions: Both the PC and LC secured all vessel sizes to well above physiologic levels. The EBVS can be used confidently in vessels up to 7 mm. There is no difference in the thermal spread of the LigaSure vessel sealer and the UCS.
引用
收藏
页码:1228 / 1230
页数:3
相关论文
共 50 条
  • [21] Comparison of census data between 1996 and 2000 on medium- and large-sized diurnal mammals, especially monkeys, at Mahale.
    Uehara, S
    ANTHROPOLOGICAL SCIENCE, 2002, 110 (01) : 63 - 63
  • [22] Energy management techniques for small- and medium-sized companies (ESDA2006-95808)
    Giacone, Elena
    Manco, Salvatore
    Gabriele, Pietro
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2008, 130 (01):
  • [23] Energy practices among small- and medium-sized tourism enterprises: a case of misdirected effort?
    Coles, Tim
    Dinan, Claire
    Warren, Neil
    JOURNAL OF CLEANER PRODUCTION, 2016, 111 : 399 - 408
  • [24] CELSIUS: an international project providing integrated, systematic, cost-effective large-scale IoT solutions for improving energy efficiency of medium- and large-sized buildings
    Ma Z.
    Santos A.Q.
    Shaker H.R.
    Yussof S.
    Eriksen P.M.
    Hornum J.
    Jørgensen B.N.
    Energy Informatics, 2022, 5 (Suppl 4)
  • [25] Comparison of safety and efficacy of ultrasonic and bipolar thermal energy - An experimental study
    Diamantis, Theodoros
    Gialikaris, Spyridon
    Kontos, Michael
    Gakiopoulou, Chariklia
    Felekouras, Evangelos
    Papalois, Apostolos
    Agrogiannis, George
    Patsouris, Efstratios
    Bastounis, Elias
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2008, 18 (04): : 384 - 390
  • [26] Statistical analysis and application of energy-consumption parameters of large-sized thermal power plants
    Li, Li-Ping
    Niu, Yu-Guang
    Zhang, Chun-Fa
    Wang, Hui-Jie
    Reneng Dongli Gongcheng/Journal of Engineering for Thermal Energy and Power, 2007, 22 (06): : 661 - 664
  • [27] Bursting tension of medium and large canine arteries sealed with ultrasonic energy or suture ligation
    Bubenik, LJ
    Hosgood, G
    Vasanjee, SC
    VETERINARY SURGERY, 2005, 34 (03) : 289 - 293
  • [28] An Effective Model for Calculations of the Hydrophobic Component of the Gibbs Energy of Solution of Small- and Medium-Sized Molecules
    Grigor'ev, F. V.
    Romanov, A. N.
    Sulimov, V. B.
    RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A, 2010, 84 (02) : 195 - 202
  • [29] An effective model for calculations of the hydrophobic component of the Gibbs energy of solution of small- and medium-sized molecules
    F. V. Grigor’ev
    A. N. Romanov
    V. B. Sulimov
    Russian Journal of Physical Chemistry A, 2010, 84 : 195 - 202
  • [30] Adoption of energy efficiency measures in the buildings of micro-, small- and medium-sized Portuguese enterprises
    Cunha, Paulo
    Neves, Sonia Almeida
    Marques, Antonio Cardoso
    Serrasqueiro, Zelia
    ENERGY POLICY, 2020, 146