Calibration of a wide-field frequency-domain fluorescence lifetime microscopy system using light emitting diodes as light sources

被引:32
|
作者
Elder, A. D.
Frank, J. H.
Swartling, J.
Dai, X.
Kaminski, C. F.
机构
[1] Univ Cambridge, Dept Chem Engn, Cambridge CB2 3RA, England
[2] Sandia Natl Labs, Livermore, CA USA
关键词
D O I
10.1111/j.1365-2818.2006.01689.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
High brightness light emitting diodes are an inexpensive and versatile light source for wide-field frequency-domain fluorescence lifetime imaging microscopy. In this paper a full calibration of an LED based fluorescence lifetime imaging microscopy system is presented for the first time. A radio-frequency generator was used for simultaneous modulation of light emitting diode (LED) intensity and the gain of an intensified charge coupled device (CCD) camera. A homodyne detection scheme was employed to measure the demodulation and phase shift of the emitted fluorescence, from which phase and modulation lifetimes were determined at each image pixel. The system was characterized both in terms of its sensitivity to measure short lifetimes (500 ps to 4 ns), and its capability to distinguish image features with small lifetime differences. Calibration measurements were performed in quenched solutions containing Rhodamine 6G dye and the results compared to several independent measurements performed with other measurement methodologies, including time correlated single photon counting, time gated detection, and acousto optical modulator (AOM) based modulation of excitation sources. Results are presented from measurements and simulations. The effects of limited signal-to-noise ratios, baseline drifts and calibration errors are discussed in detail. The implications of limited modulation bandwidth of high brightness, large area LED devices (similar to 40 MHz for devices used here) are presented. The results show that phase lifetime measurements are robust down to sub ns levels, whereas modulation lifetimes are prone to errors even at large signal-to-noise ratios. Strategies for optimizing measurement fidelity are discussed. Application of the fluorescence lifetime imaging microscopy system is illustrated with examples from studies of molecular mixing in microfluidic devices and targeted drug delivery research.
引用
收藏
页码:166 / 180
页数:15
相关论文
共 50 条
  • [31] A practical implementation of multifrequency widefield frequency-domain fluorescence lifetime imaging microscopy
    Chen, Hongtao
    Gratton, Enrico
    MICROSCOPY RESEARCH AND TECHNIQUE, 2013, 76 (03) : 282 - 289
  • [32] Theoretical investigation of the photon efficiency in frequency-domain fluorescence lifetime imaging microscopy
    Elder, Alan
    Schlachter, Simon
    Kaminski, Clemens F.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2008, 25 (02) : 452 - 462
  • [33] Light-emitting diode flashlights as effective and inexpensive light sources for fluorescence microscopy
    Robertson, J. B.
    Zhang, Y.
    Johnson, C. H.
    JOURNAL OF MICROSCOPY, 2009, 236 (01) : 1 - 4
  • [34] Design, calibration, and characterization of a field radiometer using light-emitting diodes as detectors
    Czapla-Myers, Jeffrey S.
    Thome, Kurtis J.
    Biggar, Stuart F.
    APPLIED OPTICS, 2008, 47 (36) : 6753 - 6762
  • [35] Light- field tomographic fluorescence lifetime imaging microscopy
    Ma, Yayao
    Park, Jongchan
    Huang, Luzhe
    Sen, Chandani
    Burri, Samuel
    Bruschini, Claudio
    Yang, Xilin
    Cui, Qi
    Cameron, Robert B.
    Fishbein, Gregory A.
    Gomperts, Brigitte N.
    Ozcan, Aydogan
    Charbon, Edoardo
    Gao, Liang
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2024, 121 (40)
  • [36] Electro-optic imaging enables efficient wide-field fluorescence lifetime microscopy
    Adam J. Bowman
    Brannon B. Klopfer
    Thomas Juffmann
    Mark A. Kasevich
    Nature Communications, 10
  • [37] Optical refocusing three-dimensional wide-field fluorescence lifetime imaging microscopy
    Wu, Qiang
    Guo, Shangyu
    Ma, Yinxing
    Gao, Feng
    Yang, Chengliang
    Yang, Ming
    Yu, Xuanyi
    Zhang, Xinzheng
    Rupp, Romano A.
    Xu, Jingjun
    OPTICS EXPRESS, 2012, 20 (02): : 960 - 965
  • [38] Electro-optic imaging enables efficient wide-field fluorescence lifetime microscopy
    Bowman, Adam J.
    Klopfer, Brannon B.
    Juffmann, Thomas
    Kasevich, Mark A.
    NATURE COMMUNICATIONS, 2019, 10 (1)
  • [39] Wide-field photon counting fluorescence lifetime imaging microscopy: application to photosynthesizing systems
    Zdeněk Petrášek
    Hann-Jörg Eckert
    Klaus Kemnitz
    Photosynthesis Research, 2009, 102 : 157 - 168
  • [40] Wide-field photon counting fluorescence lifetime imaging microscopy: application to photosynthesizing systems
    Petrasek, Zdenek
    Eckert, Hann-Joerg
    Kemnitz, Klaus
    PHOTOSYNTHESIS RESEARCH, 2009, 102 (2-3) : 157 - 168