Ex vivo evaluation of artifacts mimicking fracture lines on cone-beam computed tomography produced by different root canal sealers

被引:44
|
作者
Brito-Junior, M. [1 ,2 ]
Santos, L. A. N. [3 ]
Faria-e-Silva, A. L. [4 ]
Pereira, R. D. [5 ]
Sousa-Neto, M. D. [2 ]
机构
[1] Univ Estadual Montes Claros, Interinst PhD program, Montes Claros, MG, Brazil
[2] Univ Sao Paulo, Dept Restorat Dent, Fac Dent, BR-14049 Ribeirao Preto, Brazil
[3] Univ Estadual Montes Claros, Dept Dent, Montes Claros, MG, Brazil
[4] Univ Fed Sergipe, Dept Dent, Sch Dent, Aracaju, Brazil
[5] United Univ North Minas, Dept Dent, Montes Claros, MG, Brazil
关键词
cone-beam computed tomography; root canal sealer; root fracture; striking artifacts; INTRACANAL METALLIC POST; VOLUMETRIC TOMOGRAPHY; TREATED TEETH; ABSENCE; SCAN;
D O I
10.1111/iej.12121
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
AimTo evaluate streaking artifacts produced by several root canal sealers on CBCT images with variations in voxel resolution. MethodologySingle-rooted premolars were selected and root filled using gutta-percha cones and one of the following sealers: Endofill, Sealer 26, Fillapex or AH Plus. Root canals filled only with gutta-percha were used as control. Scans of teeth using a small-volume CBCT were performed, and the images acquired were evaluated by two calibrated observers (k>0.75). Artifacts were identified as streaks and dark bands on root dentine in axial slices with 2 voxel sizes (0.076 and 0.2mm). Fisher's exact test (P<0.05) was used to compare the presence/absence ratio of artifacts considering the factors sealer' and voxel size'. ResultsFor the 0.20mm voxel size, Sealer 26 had significantly more artifacts than Fillapex (P=0.006) or AH Plus (P=0.017). No differences existed between the sealers when the 0.07mm voxel size was used. Sealer 26 (P=0.042) and Endofill (P=0.035) had significantly more artifacts in the 0.20mm voxel size than with the 0.076mm voxel size, whilst no difference was noted for other filling conditions. ConclusionsThe material used for root filling and the voxel resolution can influence the presence of streaking artifacts observed in CBCT images.
引用
收藏
页码:26 / 31
页数:6
相关论文
共 50 条
  • [31] In Vivo Detection of Subtle Vertical Root Fracture in Endodontically Treated Teeth by Cone-beam Computed Tomography
    Zhang, Lei
    Wang, Tiemei
    Cao, Ya
    Wang, Congyue
    Tan, Baochun
    Tang, Xuna
    Tan, Renxiang
    Lin, Zitong
    JOURNAL OF ENDODONTICS, 2019, 45 (07) : 856 - 862
  • [32] Evaluation of artifacts generated by zirconium implants in cone-beam computed tomography images
    Vasconcelos, Taruska Ventorini
    Bechara, Boulos B.
    McMahan, Clyde Alex
    Freitas, Deborah Queiroz
    Noujeim, Marcel
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2017, 123 (02): : 265 - 272
  • [33] Cone-Beam Computed Tomography (CBCT) to Computed Tomography (CT) Image Translation with Perceptual Loss to Eliminate Cone-Beam Artifacts
    Yoo, S.
    Choi, B.
    Park, I.
    Kim, J.
    Kim, H.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [34] Cone-Beam Computed Tomographic Evaluation of Spontaneously Healed Root Fracture
    Orhan, Kaan
    Aksoy, Umut
    Kalender, Atakan
    JOURNAL OF ENDODONTICS, 2010, 36 (09) : 1584 - 1587
  • [35] Evaluation of Cone-beam Computed Tomography in the Diagnosis of Vertical Root Fractures: The Influence of Imaging Modes and Root Canal Materials
    Neves, Frederico Sampaio
    Freitas, Deborah Queiroz
    Flores Campos, Paulo Sergio
    Ekestubbe, Annika
    Lofthag-Hansen, Sara
    JOURNAL OF ENDODONTICS, 2014, 40 (10) : 1530 - 1536
  • [36] Effectiveness of limited cone-beam computed tomography in the detection of horizontal root fracture
    Kamburoglu, Kivanc
    Cebeci, A. R. Ilker
    Grondahl, Hans Goran
    DENTAL TRAUMATOLOGY, 2009, 25 (03) : 256 - 261
  • [37] Effect of root canal filling materials on dimensions of cone-beam computed tomography images
    Decurcio, Daniel Almeida
    Bueno, Mike Reis
    Goncalves de Alencar, Ana Helena
    Lyra Porto, Olavo Cesar
    Azevedo, Bruno Correa
    Estrela, Carlos
    JOURNAL OF APPLIED ORAL SCIENCE, 2012, 20 (02) : 260 - 267
  • [38] Evaluation of Cone-beam Computed Tomography Artifacts Produced by Metal Objects Located Within and Outside the Field of View
    Kassabji, Ahmad
    Tahmasbi, Mehrnaz
    Augsburger, Robert A.
    Nair, Madhu
    Kesterke, Matthew J.
    Jalali, Poorya
    JOURNAL OF ENDODONTICS, 2022, 48 (02) : 249 - 254
  • [39] Root Anatomy and Canal Configuration of Maxillary Premolars: A Cone-beam Computed Tomography Study
    Monardes, H.
    Herrera, K.
    Vargas, J.
    Steinfort, K.
    Zaror, C.
    Abarca, J.
    INTERNATIONAL JOURNAL OF MORPHOLOGY, 2021, 39 (02): : 463 - 468
  • [40] Evaluation of the Mandibular Canal Visibility on Cone-Beam Computed Tomography Images of the Mandible
    Shokri, Abbas
    Shakibaei, Zahra
    Langaroodi, Adineh Javadian
    Safaei, Mehran
    JOURNAL OF CRANIOFACIAL SURGERY, 2014, 25 (03) : E273 - E277