In Vivo Detection of Subtle Vertical Root Fracture in Endodontically Treated Teeth by Cone-beam Computed Tomography

被引:32
|
作者
Zhang, Lei [1 ]
Wang, Tiemei [2 ]
Cao, Ya [2 ]
Wang, Congyue [3 ]
Tan, Baochun [4 ]
Tang, Xuna [5 ]
Tan, Renxiang [6 ,7 ]
Lin, Zitong [2 ]
机构
[1] Nanjing Univ, Sch Med, Nanjing Stomatol Hosp, Dept Prosthodont, Nanjing, Jiangsu, Peoples R China
[2] Nanjing Univ, Sch Med, Nanjing Stomatol Hosp, Dept Dentomaxillofacial Radiol, Zhong Yang Rd 30, Nanjing 210008, Jiangsu, Peoples R China
[3] Nanjing Univ, Sch Med, Nanjing Stomatol Hosp, Dept Oral & Maxillofacial Surg, Nanjing, Jiangsu, Peoples R China
[4] Nanjing Univ, Sch Med, Nanjing Stomatol Hosp, Dept Periodontol, Nanjing, Jiangsu, Peoples R China
[5] Nanjing Univ, Sch Med, Nanjing Stomatol Hosp, Dept Endodont, Nanjing, Jiangsu, Peoples R China
[6] Nanjing Univ, Inst Funct Biomol, State Key Lab Pharmaceut Biotechnol, Nanjing, Jiangsu, Peoples R China
[7] Nanjing Univ Chinese Med, State Key Lab Cultivat Base Tradit Chinese Med Qu, Nanjing, Jiangsu, Peoples R China
关键词
Cone-beam computed tomography; fracture line; vertical bone loss; vertical root factures; PERIAPICAL RADIOGRAPHY; DIAGNOSTIC-ACCURACY; VITRO; CBCT;
D O I
10.1016/j.joen.2019.03.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this study was to evaluate the diagnostic accuracy of cone-beam computed tomographic (CBCT) imaging in the detection of subtle vertical root fractures (VRFs) in endodontically treated teeth in vivo and to discuss direct and indirect evidence for the diagnosis of subtle VRFs. Methods: Twenty-nine endodontically treated teeth with suspected VRFs from 29 patients were examined using CBCT imaging. CBCT images were scored based on evaluation of the fracture line and vertical buccopalatal (lingual) bone loss. VRF was diagnosed only when a definite fracture line was detected on CBCT images, and findings of periodontal exploration or surgical extraction were considered the gold standard. The diagnostic sensitivity, specificity, and accuracy were assessed. Results: Of the 29 teeth, 27 were positive and 2 were negative for VRF according to the gold standard. Sensitivity, specificity, and accuracy were 33.3%, 100%, and 37.9%, respectively, based on the direct finding of a fracture line on CBCT images. However, vertical buccopalatal (lingual) bone loss was found in 25 of 27 teeth with VRFs. Conclusions: Although the accuracy of CBCT imaging for the diagnosis of subtle VRFs in endodontically treated teeth in vivo was poor, vertical buccopalatal (lingual) bone loss is an important indirect sign for the diagnosis of VRFs, which can be found on CBCT images.
引用
收藏
页码:856 / 862
页数:7
相关论文
共 50 条
  • [1] Detection of Vertical Root Fractures In Vivo in Endodontically Treated Teeth by Cone-Beam Computed Tomography Scans
    Metska, Maria Elissavet
    Aartman, Irene Helena Adriana
    Wesselink, Paul Rudolf
    Ozok, Ahmet Rifat
    JOURNAL OF ENDODONTICS, 2012, 38 (10) : 1344 - 1347
  • [2] Diagnosis of Vertical Root Fractures in Endodontically Treated Teeth by Cone-Beam Computed Tomography
    Mizuhashi, Fumi
    Watarai, Yuko
    Ogura, Ichiro
    JOURNAL OF IMAGING, 2022, 8 (03)
  • [3] Detection of Vertical Root Fractures in Endodontically Treated Teeth by a Cone Beam Computed Tomography Scan
    Hassan, Bassam
    Metska, Maria Elissavet
    Ozok, Ahmet Rifat
    van der Stelt, Paul
    Wesselink, Paul Rudolf
    JOURNAL OF ENDODONTICS, 2009, 35 (05) : 719 - 722
  • [4] Cone-beam Computed Tomography for Detecting Vertical Root Fractures in Endodontically Treated Teeth: A Systematic Review
    Chang, Edwin
    Lam, Ernest
    Shah, Prakesh
    Azarpazhooh, Amir
    JOURNAL OF ENDODONTICS, 2016, 42 (02) : 177 - 185
  • [5] Detection of vertical root fractures in endodontically treated teeth in the absence and in the presence of metal post by cone-beam computed tomography
    de Menezes, Rebeca Ferraz
    de Araujo, Natalia Costa
    Costa Santa Rosa, Joedy Maria
    Macedo Carneiro, Vanda Sanderana
    dos Santos Neto, Alexandrino Pereira
    Costa, Vanio
    Moreno, Lara Marques
    Miranda, Jessica Meirinhos
    de Albuquerque, Diana Santana
    Albuquerque, Monica
    dos Santos, Roberto Alves
    Marquez de Martinez Gerbi, Marleny Elizabeth
    BMC ORAL HEALTH, 2016, 16
  • [6] Diagnostic efficacy of cone-beam computed tomography for detection of vertical root fractures in endodontically treated teeth: a systematic review
    Habibzadeh, Sareh
    Ghoncheh, Zahra
    Kabiri, Pedram
    Mosaddad, Seyed Ali
    BMC MEDICAL IMAGING, 2023, 23 (01)
  • [7] Detection of vertical root fractures in endodontically treated teeth in the absence and in the presence of metal post by cone-beam computed tomography
    Rebeca Ferraz de Menezes
    Natália Costa de Araújo
    Joedy Maria Costa Santa Rosa
    Vanda Sanderana Macêdo Carneiro
    Alexandrino Pereira dos Santos Neto
    Vânio Costa
    Lara Marques Moreno
    Jéssica Meirinhos Miranda
    Diana Santana de Albuquerque
    Mônica Albuquerque
    Roberto Alves dos Santos
    Marleny Elizabeth Márquez de Martínez Gerbi
    BMC Oral Health, 16
  • [8] Diagnostic efficacy of cone-beam computed tomography for detection of vertical root fractures in endodontically treated teeth: a systematic review
    Sareh Habibzadeh
    Zahra Ghoncheh
    Pedram Kabiri
    Seyed Ali Mosaddad
    BMC Medical Imaging, 23
  • [9] Vertical root fracture detection with cone-beam computed tomography in Biodentine™ filled teeth
    Van Acker, Jakob W. G.
    Yvergneaux, Charlotte
    Jacquet, Wolfgang
    Dierens, Melissa
    Hommez, Geert
    Van Acker, Joris
    Boone, Matthieu
    Rajasekharan, Sivaprakash
    Martens, Luc C.
    BMC ORAL HEALTH, 2024, 24 (01):
  • [10] Accuracy of Cone-beam Computed Tomography in the Detection of a Second Mesiobuccal Root Canal in Endodontically Treated Teeth: An Ex Vivo Study
    Mirmohammadi, Hesam
    Mahdi, Lamees
    Partovi, Poerya
    Khademi, Abbasali
    Shemesh, Hagay
    Hassan, Bassam
    JOURNAL OF ENDODONTICS, 2015, 41 (10) : 1678 - 1681