Pulse oximeter plethysmograph waveform and automated oscillometric sphygmomanometer for ankle-brachial index measurement

被引:1
|
作者
Arnold, Cosby G. [1 ]
Walker, J. Richard [2 ]
Metter, E. Jeffrey [3 ]
Young, Shane [2 ]
Brady, Mark F. [2 ]
机构
[1] Univ Colorado, Sch Med, Dept Emergency Med, Denver, CO USA
[2] Univ Tennessee, Hlth Sci Ctr, Dept Emergency Med, Memphis, TN USA
[3] Univ Tennessee, Hlth Sci Ctr, Dept Neurol, Memphis, TN USA
来源
关键词
Ankle-brachial index; Pulse oximetry; Plethysmography; Vascular sufficiency;
D O I
10.1016/j.ajem.2020.10.042
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: There are limited non-invasive methods to assess lower extremity arterial injuries in the emergency department (ED) and pre-hospital setting. The ankle-brachial index (ABI) requires careful auscultation by Doppler, an approach made difficult in noisy environments. We sought to determine the agreement of the ABI measured using the pulse oximeter plethysmograph waveform (Pleth) with auscultation by Doppler in a controlled setting. A secondary outcome sought to examine the agreement of ABI by automated oscillometric sphygmomanometer (AOS) with Doppler. Methods: We measured blood pressure in the right upper and lower extremities of healthy volunteers using: (1) Doppler and manual sphygmomanometer; (2) Pleth and manual sphygmomanometer; and (3) AOS. The Bland-Altman approach to assessing agreement between methods was used comparing mean differences between ABI pairs to their means for Doppler versus Pleth and Doppler versus AOS. The intraclass correlation coefficient (ICC) from mixed effects models examined intraand inter-rater reliability. Results: Among 100 participants with normal ABI the mean ABI (95%CI) were Doppler 1.11 (0.90-1.33), Pleth 1.10 (0.91-1.30), and AOS 1.10 (0.90-1.30). The ABI difference (95% CI for limits of agreement) were 0.01 (-0.20,0.18) for Doppler-Pleth and 0.02 (-0.26, 0.22) for Doppler-AOS. The ICC for the Doppler-Pleth comparison (ICC = 0.56, 95% CI 0.47-0.63) was greater than for the Doppler-AOS (ICC = 0.32, 95% CI 0.19-0.43). Conclusions: The ABI measured using the Pleth has a high level of agreement with measurement by Doppler. The AOS and Doppler have good agreement with greater measurement variability. Pleth and AOS may be reasonable alternatives to Doppler for ABI. (c) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:162 / 165
页数:4
相关论文
共 50 条
  • [1] Oscillometric measurement of the ankle-brachial index
    MacDougall, Andrea M.
    Tandon, Vikas
    Wilson, Merne P.
    Wilson, Thomas W.
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2008, 24 (01) : 49 - 51
  • [2] Ankle-Brachial Index Measured Using Pulse Oximeter Plethysmograph Waveform and Automated Blood Pressure Device to Assess Lower Extremity Vascular Integrity
    Arnold, C. G.
    Walker, J. R., III
    Young, S.
    Brady, M. F.
    [J]. ANNALS OF EMERGENCY MEDICINE, 2019, 74 (04) : S40 - S40
  • [3] Ankle-Brachial Index Measurement With an Automated Oscillometric Blood Pressure Cuff: Bringing the Ankle-Brachial Index Back to the Bedside
    Dufresne, Laurence
    Jetty, Prasad
    [J]. JOURNAL OF VASCULAR SURGERY, 2018, 68 (03) : E89 - E89
  • [4] Validation of automated oscillometric versus manual measurement of the ankle-brachial index
    Richart, T.
    Kouznetsova, T.
    Wizner, B.
    Struijker-Boudier, H.
    Staessen, J.
    [J]. JOURNAL OF HYPERTENSION, 2008, 26 : S499 - S499
  • [5] Validation of automated oscillometric versus manual measurement of the ankle-brachial index
    Richart, Tom
    Kuznetsova, Tatiana
    Wizner, Barbara
    Struijker-Boudier, Harry A.
    Staessen, Jan A.
    [J]. HYPERTENSION RESEARCH, 2009, 32 (10) : 884 - 888
  • [6] Validity and reliability of the ankle-brachial index by oscillometric blood pressure and automated ankle-brachial index
    Chongthawonsatid, Sukanya
    Dutsadeevettakul, Somchai
    [J]. JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2017, 22
  • [7] Automated oscillometric measurement of the ankle-brachial index in patients with coronary artery disease
    Sinski, Maciej
    Styczynski, Grzegorz
    Szmigielski, Cezary
    [J]. HYPERTENSION RESEARCH, 2013, 36 (01) : 25 - 28
  • [8] Assessing ankle-brachial index (ABI) by using automated oscillometric devices
    Kawamura, Takao
    [J]. ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2008, 90 (05) : 322 - 326
  • [9] The Accuracy and Reliability of Automated Oscillometric Measurement of Ankle-Brachial Index in the Diagnosis of Peripheral Artery Disease
    Fu, Guanqi
    Jiang, Rui
    Qian, Cheng
    Liu, Zhengli
    Kong, Jie
    Gong, Maofeng
    Wang, Tao
    He, Xu
    [J]. ANNALS OF VASCULAR SURGERY, 2024, 100 : 1 - 7
  • [10] Correlation of ankle-brachial index measured by doppler sphygmomanometer and automatic oscillometric device in elderly patients
    Miranda, Roberto Dischinger
    Mateos Filho, Dionisio Alvarez
    Gomes, Marco Antonio Mota
    de Magalhaes Feitosa, Audes Diogenes
    Almada Filho, Clineu de Mello
    Toniolo Neto, Joao
    Cendoroglo, Maysa Seabra
    [J]. ATHEROSCLEROSIS SUPPLEMENTS, 2007, 8 (03) : 12 - 12