Validity and reliability of the ankle-brachial index by oscillometric blood pressure and automated ankle-brachial index

被引:8
|
作者
Chongthawonsatid, Sukanya [1 ]
Dutsadeevettakul, Somchai [2 ]
机构
[1] Mahidol Univ, Fac Social Sci & Humanities, Dept Social Sci, Salaya 73170, Nakhon Pathom, Thailand
[2] Mahidol Univ, Dept Med, Golden Jubilee Med Ctr, Salaya 73170, Nakhon Pathom, Thailand
关键词
Automated ankle-brachial index; oscillometric blood pressure; peripheral arterial disease; reliability; validity; PERIPHERAL ARTERIAL-DISEASE; VASCULAR-DISEASE; DOPPLER METHOD; DEVICE; STANDARDS;
D O I
10.4103/jrms.JRMS_728_16
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This study was conducted to assess the validity and reliability of ankle-brachial index (ABI) by oscillometric blood pressure (BP) measurement as compared with an automated ABI as a gold standard. Materials and Methods: This study was conducted at Golden Jubilee Medical Center, Thailand. All the data were collected from 303 patients at risk of peripheral arterial disease (PAD) who were 45 years of age or above and who underwent treatment at the outpatient medical clinic between June and December 2015. Patients who were followed up at the medical clinic had both oscillometric BP measurement (Terumo, ES-P600) and an automated ABI (oscillometric method) at the same time. Sensitivity, specificity, positive predictive value, and negative predictive value of the oscillometric BP measurements to predict an abnormal ABI (< 0.90) were determined using the automated ABI as the gold standard. Results: ABI values were similar between the two methods. The oscillometric BP method for determining an ABI (cutoff point < 0.90) on the right side had a sensitivity of 88.89%, specificity of 99.32%, an accuracy of 99.01%, a positive predictive value of 80%, and a negative predictive value of 99.32% whereas ABI on the left side had a sensitivity of 69.23%, a specificity of 99.66%, an accuracy of 98.35%, a positive predictive value of 90%, and a negative predictive value of 98.63%. Reliability of the oscillometric BP method by Kappa statistics was 0.84 on the right side and 0.77 on the left side (P = 0.000). Conclusion: The oscillometric BP method is a reliable and useful alternative to conventional automated ABI determination in patients with no severe arterial occlusion for estimation of the prevalence and screening of PAD in primary health-care settings.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Ankle-Brachial Index Measurement With an Automated Oscillometric Blood Pressure Cuff: Bringing the Ankle-Brachial Index Back to the Bedside
    Dufresne, Laurence
    Jetty, Prasad
    [J]. JOURNAL OF VASCULAR SURGERY, 2018, 68 (03) : E89 - E89
  • [2] Oscillometric measurement of the ankle-brachial index
    MacDougall, Andrea M.
    Tandon, Vikas
    Wilson, Merne P.
    Wilson, Thomas W.
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2008, 24 (01) : 49 - 51
  • [3] Ankle-brachial index
    Ponka, David
    Baddar, Faisal
    [J]. CANADIAN FAMILY PHYSICIAN, 2013, 59 (03) : 270 - 270
  • [4] Ankle-brachial index
    Er, F.
    Erdmann, E.
    [J]. DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2009, 134 (40) : 2015 - 2016
  • [5] Assessing ankle-brachial index (ABI) by using automated oscillometric devices
    Kawamura, Takao
    [J]. ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2008, 90 (05) : 322 - 326
  • [6] Validation of automated oscillometric versus manual measurement of the ankle-brachial index
    Richart, T.
    Kouznetsova, T.
    Wizner, B.
    Struijker-Boudier, H.
    Staessen, J.
    [J]. JOURNAL OF HYPERTENSION, 2008, 26 : S499 - S499
  • [7] Validation of automated oscillometric versus manual measurement of the ankle-brachial index
    Richart, Tom
    Kuznetsova, Tatiana
    Wizner, Barbara
    Struijker-Boudier, Harry A.
    Staessen, Jan A.
    [J]. HYPERTENSION RESEARCH, 2009, 32 (10) : 884 - 888
  • [8] Ankle-Brachial Index in Migraineurs
    Evans, Randolph W.
    [J]. HEADACHE, 2010, 50 (07): : 1215 - 1216
  • [10] Association of blood pressure with ankle-brachial index and ankle-brachial pulse wave velocity in hypertensive Chinese adults
    Jiang, Jiandong
    Han, Chungen
    Wang, Yu
    Li, Aimin
    Fu, Jia
    Yang, Jianhua
    Xing, Houxun
    Li, Zhiping
    Xu, Xiping
    Sun, Ningling
    Li, Xiaoying
    Liu, Lisheng
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 137 : S64 - S65