Poly-dimethyl-siloxane (PDMS) contamination of polystyrene (PS) oligomers samples:: a comparison of time-of-flight static secondary ion mass spectrometry (TOF-SSIMS) and X-ray photoelectron spectroscopy (XPS) results

被引:40
|
作者
Oran, U [1 ]
Ünveren, E [1 ]
Wirth, T [1 ]
Unger, WES [1 ]
机构
[1] Bundesanstalt Mat Forsch & Prufung, Lab Thin Film & Surface Anal, D-12203 Berlin, Germany
关键词
PDMS; TOF-SIMS; polystyrene; segregation;
D O I
10.1016/j.apsusc.2003.12.008
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Pure and PDMS contaminated PS oligomers films were investigated both by time-of-flight static secondary ion mass spectrometry (TOF-SSIMS) and X-ray photoelectron spectroscopy (XPS). The secondary ion spectra from the PDMS contaminated PS oligomers were almost completely related to PDMS. XPS revealed a PDMS contamination characterized by a silicon surface concentration of 6 at.%. Obviously siloxane contaminants existing on the surface of a silicon wafer may diffuse towards the PS oligomers outermost surface resulting in a rather high PDMS surface concentration of about 85%. Due to the known differences in the information depth and sensitivity of SSIMS and XPS very different detection limits are to be considered. In elimination of siloxane contaminants by ultrasonication in hexane was found to be an effective way. Another common organic cleaning procedure, which is ultrasonication in trichloroethylene (TCE), subsequently in isopropanol and finally in acetone was found to be ineffective for cleaning of PDMS contaminated silicon wafers. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:318 / 324
页数:7
相关论文
共 50 条
  • [21] Defects of clean graphene and sputtered graphite surfaces characterized by time-of-flight secondary ion mass spectrometry and X-ray photoelectron spectroscopy
    Xie, Wenjing
    Weng, Lu-Tao
    Ng, Kai Mo
    Chan, Chak K.
    Chan, Chi-Ming
    CARBON, 2017, 112 : 192 - 200
  • [22] Interaction of Bovine Serum Albumin and Lysozyme with Stainless Steel Studied by Time-of-Flight Secondary Ion Mass Spectrometry and X-ray Photoelectron Spectroscopy
    Hedberg, Yolanda S.
    Killian, Manuela S.
    Blomberg, Eva
    Virtanen, Sannakaisa
    Schmuki, Patrik
    Wallinder, Inger Odnevall
    LANGMUIR, 2012, 28 (47) : 16306 - 16317
  • [23] Sulfonation of poly(N-vinylcarbazole) studied by combined time of-flight secondary ion mass spectrometry and X-ray photoelectron spectroscopy
    Weng, LT
    Wong, PCL
    Ho, K
    Wang, SH
    Zeng, ZH
    Yang, SH
    ANALYTICAL CHEMISTRY, 2000, 72 (20) : 4908 - 4913
  • [24] Adsorption of poly(methyl methacrylate) and poly(vinyl chloride) blends onto polypyrrole - Study by X-ray photoelectron spectroscopy, time-of-flight static secondary ion mass spectroscopy, and inverse gas chromatography
    Abel, ML
    Chehimi, MM
    Fricker, F
    Delamar, M
    Brown, AM
    Watts, JF
    JOURNAL OF CHROMATOGRAPHY A, 2002, 969 (1-2) : 273 - 285
  • [25] Aluminum chemical vapor deposition reaction of dimethylaluminum hydride on TiN studied by X-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectrometry
    Tanaka, K
    Yanashima, H
    Yako, T
    Kamio, K
    Sugai, K
    Kishida, S
    APPLIED SURFACE SCIENCE, 2001, 171 (1-2) : 71 - 81
  • [26] A TIME-OF-FLIGHT STATIC SECONDARY ION MASS-SPECTROMETRY AND X-RAY PHOTOELECTRON-SPECTROSCOPY STUDY OF 3-AMINOPROPYLTRIHYDROXYSILANE ON WATER PLASMA TREATED CHROMIUM AND SILICON SURFACES
    ELDRIDGE, BN
    BUCHWALTER, LP
    CHESS, CA
    GOLDBERG, MJ
    GOLDBLATT, RD
    NOVAK, FP
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 1992, 6 (01) : 109 - 125
  • [28] Comparison of submicron particle analysis by Auger electron spectroscopy, time-of-flight secondary ion mass spectrometry, and secondary electron microscopy with energy dispersive x-ray spectroscopy
    Childs, KD
    Narum, D
    LaVanier, LA
    Lindley, PM
    Schueler, BW
    Mulholland, G
    Diebold, AC
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1996, 14 (04): : 2392 - 2404
  • [29] STATIC SECONDARY ION MASS-SPECTROMETRY AND X-RAY PHOTOELECTRON-SPECTROSCOPY OF DEUTERIUM-SUBSTITUTED AND METHYL-SUBSTITUTED POLYSTYRENE
    CHILKOTI, A
    CASTNER, DG
    RATNER, BD
    APPLIED SPECTROSCOPY, 1991, 45 (02) : 209 - 217
  • [30] X-ray photoelectron emission microscopy and time-of-flight secondary ion mass spectrometry analysis of ultrathin fluoropolymer coatings for stent applications
    Hale, Penelope
    Turgeon, Stephane
    Horny, Paula
    Lewis, Francois
    Brack, Narelle
    Van Riessen, Grant
    Pigram, Paul
    Mantovani, Diego
    LANGMUIR, 2008, 24 (15) : 7897 - 7905