Research of the Influence of Rectangular Prism Pien Error on Angle Measurement for Photoelectric Autocollimator

被引:1
|
作者
Hu, Tao [1 ]
Wang, Dandan [2 ]
Li, Zhigang [1 ]
机构
[1] Harbin Inst Technol, Dept Automat Measurement & Control, Harbin 150006, Peoples R China
[2] Beijing Inst Astronaut Syst Engn, Beijing, Peoples R China
关键词
component; Autocollimator; Right angle prisms; Vector analysis;
D O I
10.1109/IMCCC.2014.98
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Photoelectric autocollimator is a kind of small angle measuring instrument of high accuracy. For the increasing demand of the measurement accuracy, each link to affect the precision of photoelectric autocollimator needs to be analyzed and derived. In view of the analysis of the lack for the right angle prism pien errors which effect on the measurement precision, this paper adopts the method of vector analysis and coordinate transformation, to solve the relationship between the image type photoelectric autocollimator reticules imaging and prism space angle. On this basis, analyze the influence of the right angle prism error on the measurement. To verify the correctness of test derivation, using a type of photoelectric autocollimator and right angle prisms for experiments, the test results coincide with the conclusion of theoretical derivation.
引用
收藏
页码:439 / 442
页数:4
相关论文
共 39 条
  • [31] The Error Analysis and Experimental Research of Micro-angle Measurement System Based on F-P Etalon
    Zhou Shinan
    Shen Xiaoyan
    Wu Chenguang
    Li Dongsheng
    TENTH INTERNATIONAL SYMPOSIUM ON PRECISION MECHANICAL MEASUREMENTS, 2021, 12059
  • [32] Research of the Influence of Surface Color on the Measurement Error of Parameter Geometric Accuracy in Laser Scanning Optoelectronic Measurement Information Systems
    Win, Pyae Sone
    Alexey, Shulepov V.
    Petr, Emelyanov N.
    Khaing, Myo Min
    Htet, Zaw Win
    PROCEEDINGS OF THE 2019 IEEE CONFERENCE OF RUSSIAN YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING (EICONRUS), 2019, : 2113 - 2116
  • [33] Research on the error influence mechanism of infrared temperature measurement of turbine guide vanes with end walls
    Zhai Y.
    Liang Z.
    Meng X.
    Liu C.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2024, 53 (01):
  • [34] Measurement error in research on human resources and firm performance: How much error is there and how does it influence effect size estimates?
    Gerhart, B
    Wright, PM
    McMahan, GC
    Snell, SA
    PERSONNEL PSYCHOLOGY, 2000, 53 (04) : 803 - 834
  • [35] Influence of the Tube Angle on the Measurement Accuracy of Peri-Implant Bone Defects in Rectangular Intraoral X-ray Imaging
    Rugani, Petra
    Weingartner, Katharina
    Jakse, Norbert
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (02)
  • [36] Research on Multipath-Caused MLS Angle-Measurement Error Using Main Lobe Gaussian Replacement Technology
    Wu, Huaxin
    Zhao, Xiubin
    Dai, Chuanjin
    JOURNAL OF COMPUTERS, 2011, 6 (07) : 1353 - 1360
  • [37] Influence of the apex angle of a hollow prism made from an ordinary commercial glass plate as a simple refractometer to the accuracy of the refractive index measurement of the edible oil
    Idris, N.
    Maswati
    Yusibani, E.
    7TH AIC-ICMR ON SCIENCES AND ENGINEERING 2017, 2018, 352
  • [38] Comment on "Measurement error in research on human resources and firm performance: How much error is there and how does it influence effect size estimates?" by Gerhart, Wright, McMahan, and Snell
    Huselid, MA
    Becker, BE
    PERSONNEL PSYCHOLOGY, 2000, 53 (04) : 835 - 854
  • [39] Research on angle setting error of diameter measurement based on laser displacement sensors; [基于激光位移传感器圆径测量的角度安装误差研究]
    Ma J.
    Chen X.
    Ding G.
    Chen J.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2021, 50 (05):