Objective: To investigate the benefit of contralateral residual hearing in a large group of cochlear implant recipients with different degrees of residual hearing. Patients: One hundred and forty-one adult patients (age in years: mean 58.82, min 16.27, max 88.20) wearing a cochlear implant and a contralateral hearing aid, bimodal. Intervention: Rehabilitative. Main Outcome Measures: All 141 patients underwent speech perception testing in quiet and noise with cochlear implant (CI) alone, and with CI and hearing aid (HA). Additionally, pure-tone air conduction threshold levels were measured in all subjects. The bimodal benefit was analyzed and correlations to the hearing threshold for different audiometric frequencies were calculated. Results: Comparison between the scores for CI alone and CI + HA showed statistically significant advantages (p < 0.0001) in all four tests. The benefit for sentences in noise to each individual patient showed a negative correlation with the hearing threshold level of 125 Hz and 250 Hz, using a linear regression analysis applying the Spearman's rho correlation coefficient (r = -0.32, -0.232), and a significant difference at p = 0.006, p = 0.007. The correlations involving speech understanding in sentences in noise, and the hearing level of 500 Hz and above, are not significant for the benefit obtained with a contralateral hearing aid. Conclusion: The benefit of combined electric and acoustic hearing in bimodally fitted subjects depends mainly on residual hearing in the low-frequency range below 500 Hz. For bimodal fitting to yield significant benefits, hearing loss in the contralateral ear should not exceed 80 dB HL in the low frequencies.
引用
收藏
页码:E240 / E244
页数:5
相关论文
共 50 条
  • [41] Benefit of wearing a hearing aid on the unimplanted ear in adult users of a cochlear implant
    Dunn, CC
    Tyler, RS
    Witt, SA
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2005, 48 (03): : 668 - 680
  • [42] Localization of Low- and High-Frequency Sounds in Cochlear Implant Recipients Using a Contralateral Hearing Aid
    Zelger, Philipp
    Zorowka, Patrick
    Schmutzhard, Joachim
    Galvan, Oliver
    Rossi, Sonja
    Stephan, Kurt
    Seebacher, Josef
    OTOLOGY & NEUROTOLOGY, 2024, 45 (03) : e228 - e233
  • [43] An Analysis of Hearing Aid Fittings in Adults Using Cochlear Implants and Contralateral Hearing Aids
    Harris, Michael S.
    Hay-McCutcheon, Marcia
    LARYNGOSCOPE, 2010, 120 (12): : 2484 - 2488
  • [44] Contralateral hearing aid use in adult cochlear implant recipients: retrospective analysis of auditory outcomes
    Mertens, Griet
    Andries, Ellen
    Clement, Charis
    Cochet, Ellen
    Hofkens-Van den Brandt, Anouk
    Jacquemin, Laure
    Joossen, Iris
    Vermeersch, Hanne
    Lammers, Marc Jan-Willem
    Van Rompaey, Vincent
    Vanderveken, Olivier
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2024, 63 (07) : 543 - 550
  • [45] Parental insights on Hearing Aid Usage in the ear Contralateral to unilateral Cochlear Implant among Children
    Sahana, P.
    Chaithra, M. C.
    Manjula, P.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2023, 172
  • [46] Evaluation of self-esteem in hearing aid and cochlear implant users
    Satici, Sema
    Derinsu, Ufuk
    Akdeniz, Esra
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2023, 280 (06) : 2735 - 2740
  • [47] Evaluation of self-esteem in hearing aid and cochlear implant users
    Sema Satici
    Ufuk Derinsu
    Esra Akdeniz
    European Archives of Oto-Rhino-Laryngology, 2023, 280 : 2735 - 2740
  • [48] Children using a unilateral cochlear implant and contralateral hearing aid: bimodal hearing outcomes when one ear is outside the UK (NICE 2009) audiological criteria for cochlear implantation - a single site case-control study
    Bruce, Iain
    Schaefer, Simone
    Kluk, Karolina
    Nichani, Jaya
    Odriscoll, Martin
    Rajai, Azita
    Sladen, Mark
    BMJ OPEN, 2023, 13 (06):
  • [49] Recognition and Localization of Speech by Adult Cochlear Implant Recipients Wearing a Digital Hearing Aid in the Nonimplanted Ear (Bimodal Hearing)
    Potts, Lisa G.
    Skinner, Margaret W.
    Litovsky, Ruth A.
    Strube, Michael J.
    Kuk, Francis
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2009, 20 (06) : 353 - 373
  • [50] Genetic Causes of Hearing Loss in a Large Cohort of Cochlear Implant Recipients
    Seligman, Kristen L.
    Shearer, A. Eliot
    Frees, Kathy
    Nishimura, Carla
    Kolbe, Diana
    Dunn, Camille
    Hansen, Marlan R.
    Gantz, Bruce J.
    Smith, Richard J. H.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2022, 166 (04) : 734 - 737