Localization of Low- and High-Frequency Sounds in Cochlear Implant Recipients Using a Contralateral Hearing Aid

被引:0
|
作者
Zelger, Philipp [1 ]
Zorowka, Patrick [1 ]
Schmutzhard, Joachim [2 ]
Galvan, Oliver [1 ]
Rossi, Sonja [1 ]
Stephan, Kurt [1 ]
Seebacher, Josef [1 ]
机构
[1] Med Univ Innsbruck, Dept Hearing Speech & Voice Disorders, Innsbruck, Austria
[2] Med Univ Innsbruck, Dept Otorhinolaryngol, Innsbruck, Austria
关键词
Asymmetric hearing loss; Bimodal hearing; Cochlear implant; Hearing aid; Sound localization; HORIZONTAL LOCALIZATION; SPEECH-INTELLIGIBILITY; IDENTIFICATION; USERS;
D O I
10.1097/MAO.0000000000004090
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and ObjectivesThe ability to localize sounds is partly recovered in patients using a cochlear implant (CI) in one ear and a hearing aid (HA) on the contralateral side. Binaural processing seems effective at least to some extent, despite the difference between electric and acoustic stimulation in each ear. To obtain further insights into the mechanisms of binaural hearing in these listeners, localization of low- and high-frequency sounds was tested.Study DesignThe study used a within-subject design, where participants were tasked with localizing sound sources in the horizontal plane. The experiment was conducted in an anechoic chamber, where an array of seven loudspeakers was mounted along the 24 azimuthal angle span from -90 degrees to +90 degrees. Stimuli were applied with different frequencies: broadband noise and high- and low-frequency noise.SubjectsTen CI recipients participated in the study. All had an asymmetric hearing loss with a CI in the poorer ear and an HA on the contralateral side.Main Outcome MeasuresAccuracy of sound localization in terms of angular error and percentage of correct localization scores.ResultsThe median angular error was 40 degrees in bimodal conditions for both broadband noise and high-frequency noise stimuli. The angular error increased to 47 degrees for low-frequency noise stimuli. In the unilaterally aided condition with an HA, only a median angular error of 78 degrees was observed.ConclusionsIrrespective of the frequency composition of the stimuli, this group of bimodal listeners showed some ability to localize sounds. Angular errors were larger than those reported in the literature for bilateral CI users or single-sided deaf listeners with a CI. In the unilateral listening condition with HA, only localization of sounds was not possible for most subjects.
引用
收藏
页码:e228 / e233
页数:6
相关论文
共 50 条
  • [1] Horizontal sound localization in cochlear implant users with a contralateral hearing aid
    Veugen, Lidwien C. E.
    Hendrikse, Maartje M. E.
    van Wanrooij, Marc M.
    Agterberg, Martijn J. H.
    Chalupper, Josef
    Mens, Lucas H. M.
    Snik, Ad F. M.
    van Opstal, A. John
    [J]. HEARING RESEARCH, 2016, 336 : 72 - 82
  • [2] Unified cochlear model for low- and high-frequency mammalian hearing
    Sasmal, Aritra
    Grosh, Karl
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2019, 116 (28) : 13983 - 13988
  • [3] Sound localisation of low- and high-frequency sounds in cochlear implant users with single-sided deafness
    Seebacher, J.
    Franke-Trieger, A.
    Weichbold, V
    Galvan, O.
    Schmutzhard, J.
    Zorowka, P.
    Stephan, K.
    [J]. INTERNATIONAL JOURNAL OF AUDIOLOGY, 2023, 62 (01) : 71 - 78
  • [4] Reduction in High-Frequency Hearing Aid Gain Can Improve Performance in Patients With Contralateral Cochlear Implant: A Pilot Study
    Messersmith, Jessica J.
    Jorgensen, Lindsey E.
    Hagg, Jessica A.
    [J]. AMERICAN JOURNAL OF AUDIOLOGY, 2015, 24 (04) : 462 - 468
  • [5] Low-Frequency Pitch Perception in Cochlear Implant Recipients With Normal Hearing in the Contralateral Ear
    Dillon, Margaret T.
    Buss, Emily
    Rooth, Meredith A.
    King, English R.
    Pillsbury, Harold C.
    Brown, Kevin D.
    [J]. JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2019, 62 (08): : 2860 - 2871
  • [6] The Contribution of a Frequency-Compression Hearing Aid to Contralateral Cochlear Implant Performance
    Perreau, Ann E.
    Bentler, Ruth A.
    Tyler, Richard S.
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2013, 24 (02) : 105 - 120
  • [7] The influence of residual high-frequency hearing on the outcome in congenitally deaf cochlear implant recipients
    Kuo, SCL
    Gibson, WPR
    [J]. AMERICAN JOURNAL OF OTOLOGY, 2000, 21 (05): : 657 - 662
  • [8] Contralateral hearing aid use in adult cochlear implant recipients: retrospective analysis of auditory outcomes
    Mertens, Griet
    Andries, Ellen
    Clement, Charis
    Cochet, Ellen
    Hofkens-Van den Brandt, Anouk
    Jacquemin, Laure
    Joossen, Iris
    Vermeersch, Hanne
    Lammers, Marc Jan-Willem
    Van Rompaey, Vincent
    Vanderveken, Olivier
    [J]. INTERNATIONAL JOURNAL OF AUDIOLOGY, 2024, 63 (07) : 543 - 550
  • [9] Contralateral hearing aid use in adult cochlear implant recipients: retrospective analysis of auditory outcomes
    Mertens, Griet
    Andries, Ellen
    Clement, Charis
    Cochet, Ellen
    Hofkens-Van den Brandt, Anouk
    Jacquemin, Laure
    Joossen, Iris
    Vermeersch, Hanne
    Lammers, Marc Jan-Willem
    Van Rompaey, Vincent
    Vanderveken, Olivier
    [J]. INTERNATIONAL JOURNAL OF AUDIOLOGY, 2023,
  • [10] Benefit of contralateral hearing aid in adult cochlear implant bearers
    Bouccara, D.
    Blanchet, E.
    Waterlot, P. E.
    Smadja, M.
    Frachet, B.
    Meyer, B.
    Sterkers, O.
    [J]. EUROPEAN ANNALS OF OTORHINOLARYNGOLOGY-HEAD AND NECK DISEASES, 2016, 133 (03) : 161 - 165