Localization of Low- and High-Frequency Sounds in Cochlear Implant Recipients Using a Contralateral Hearing Aid

被引:0
|
作者
Zelger, Philipp [1 ]
Zorowka, Patrick [1 ]
Schmutzhard, Joachim [2 ]
Galvan, Oliver [1 ]
Rossi, Sonja [1 ]
Stephan, Kurt [1 ]
Seebacher, Josef [1 ]
机构
[1] Med Univ Innsbruck, Dept Hearing Speech & Voice Disorders, Innsbruck, Austria
[2] Med Univ Innsbruck, Dept Otorhinolaryngol, Innsbruck, Austria
关键词
Asymmetric hearing loss; Bimodal hearing; Cochlear implant; Hearing aid; Sound localization; HORIZONTAL LOCALIZATION; SPEECH-INTELLIGIBILITY; IDENTIFICATION; USERS;
D O I
10.1097/MAO.0000000000004090
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and ObjectivesThe ability to localize sounds is partly recovered in patients using a cochlear implant (CI) in one ear and a hearing aid (HA) on the contralateral side. Binaural processing seems effective at least to some extent, despite the difference between electric and acoustic stimulation in each ear. To obtain further insights into the mechanisms of binaural hearing in these listeners, localization of low- and high-frequency sounds was tested.Study DesignThe study used a within-subject design, where participants were tasked with localizing sound sources in the horizontal plane. The experiment was conducted in an anechoic chamber, where an array of seven loudspeakers was mounted along the 24 azimuthal angle span from -90 degrees to +90 degrees. Stimuli were applied with different frequencies: broadband noise and high- and low-frequency noise.SubjectsTen CI recipients participated in the study. All had an asymmetric hearing loss with a CI in the poorer ear and an HA on the contralateral side.Main Outcome MeasuresAccuracy of sound localization in terms of angular error and percentage of correct localization scores.ResultsThe median angular error was 40 degrees in bimodal conditions for both broadband noise and high-frequency noise stimuli. The angular error increased to 47 degrees for low-frequency noise stimuli. In the unilaterally aided condition with an HA, only a median angular error of 78 degrees was observed.ConclusionsIrrespective of the frequency composition of the stimuli, this group of bimodal listeners showed some ability to localize sounds. Angular errors were larger than those reported in the literature for bilateral CI users or single-sided deaf listeners with a CI. In the unilateral listening condition with HA, only localization of sounds was not possible for most subjects.
引用
收藏
页码:e228 / e233
页数:6
相关论文
共 50 条
  • [41] The RetroX auditory implant for high-frequency hearing loss
    Garin, P
    Genard, F
    Galle, C
    Jamart, J
    OTOLOGY & NEUROTOLOGY, 2004, 25 (04) : 511 - 519
  • [42] HEARING AID FOR SUBJECTS WITH EXTREME HIGH-FREQUENCY LOSSES
    KNORR, SG
    IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1976, 24 (06): : 473 - 480
  • [43] Binaurality in middle ear implant recipients using contralateral digital hearing aids
    Saliba, I
    Calmels, MN
    Wanna, G
    Iversenc, T
    James, C
    Deguine, O
    Fraysse, B
    OTOLOGY & NEUROTOLOGY, 2005, 26 (04) : 680 - 685
  • [44] The smaller the frequency-to-place mismatch the better the hearing outcomes in cochlear implant recipients?
    Griet Mertens
    Paul Van de Heyning
    Olivier Vanderveken
    Vedat Topsakal
    Vincent Van Rompaey
    European Archives of Oto-Rhino-Laryngology, 2022, 279 : 1875 - 1883
  • [45] The smaller the frequency-to-place mismatch the better the hearing outcomes in cochlear implant recipients?
    Mertens, Griet
    Van de Heyning, Paul
    Vanderveken, Olivier
    Topsakal, Vedat
    Van Rompaey, Vincent
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2022, 279 (04) : 1875 - 1883
  • [46] BINAURAL FUSION OF LOW-FREQUENCY AND HIGH-FREQUENCY SOUNDS
    LEAKEY, DM
    SAYERS, BM
    CHERRY, C
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1958, 30 (03): : 222 - 222
  • [47] Clinical Application of Spectral Modulation Detection: Speech Recognition Benefit for Combining a Cochlear Implant and Contralateral Hearing Aid
    Kessler, David M.
    Wolfe, Jace
    Blanchard, Michelle
    Gifford, Rene H.
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2020, 63 (05): : 1561 - 1571
  • [48] Using hearing aid adaptive directional microphones to enhance cochlear implant performance
    Chung, King
    Zeng, Fan-Gang
    HEARING RESEARCH, 2009, 250 (1-2) : 27 - 37
  • [49] Cochlear Dead Regions in Typical Hearing Aid Candidates: Prevalence and Implications for Use of High-Frequency Speech Cues
    Cox, Robyn M.
    Alexander, Genevieve C.
    Johnson, Jani
    Rivera, Izel
    EAR AND HEARING, 2011, 32 (03): : 339 - 348
  • [50] Listening Effort in Prelingual Cochlear Implant Recipients: Effects of Spectral and Temporal Auditory Processing and Contralateral Acoustic Hearing
    Yuksel, Mustafa
    Tasdemir, Ilknur
    Ciprut, Ayca
    OTOLOGY & NEUROTOLOGY, 2022, 43 (10) : E1077 - E1084