Absolute Quantitation of Intact Recombinant Antibody Product Variants Using Mass Spectrometry

被引:18
|
作者
Macchi, Frank D. [1 ]
Yang, Feng [1 ]
Li, Charlene [1 ]
Wang, Chenchen [2 ]
Anh Nguyen Dang [1 ]
Marhoul, Joseph C. [1 ]
Zhang, Hui-min [1 ]
Tully, Timothy [3 ]
Liu, Hongbin [1 ]
Yu, X. Christopher [1 ]
Michels, David A. [1 ]
机构
[1] Genentech Inc, Prot Analyt Chem, San Francisco, CA 94080 USA
[2] Eurofins Lancaster Labs Inc, Lancaster, PA 17601 USA
[3] Genentech Inc, Purificat Dev, San Francisco, CA 94080 USA
关键词
STANDARD ADDITION METHOD; MONOCLONAL-ANTIBODY; HYDROPHOBIC INTERACTION; BISPECIFIC ANTIBODIES; LC-MS/MS; QUANTIFICATION; PROTEINS; CHROMATOGRAPHY; MS; CALIBRATION;
D O I
10.1021/acs.analchem.5b02627
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Accurate and precise quantitative measurement of product-related variants of a therapeutic antibody is essential for product development and testing. Bispecific antibodies (bsAbs) are Abs composed of two different half antibody arms, each of which recognizes a distinct target, and recently they have attracted substantial therapeutic interest. Because of the increased complexity of its structure and its production process, as compared to a conventional monoclonal antibody, additional product-related variants, including covalent and noncovalent homodimers of half antibodies (hAbs), may be present in the bsAb product. Sufficient separation and reliable quantitation of these bsAb homodimers using liquid chromatography (LC) or capillary electrophoresis-based methods is challenging because these homodimer species and the bsAb often have similar physicochemical properties. Formation of noncovalent homodimers and heterodimers can also occur. In addition, since homodimers share common sequences with their corresponding halves and bsAb, it is not suitable to use peptides as surrogates for their quantitation. To tackle these analytical challenges, we developed a mass spectrometry-based quantitation method. Chip-based nanoflow LC time-of-flight mass spectrometry coupled with a standard addition approach provided unbiased absolute quantitation of these drug-product-related variants. Two methods for the addition of known levels of standard (multi- or single-addition) were evaluated. Both methods demonstrated accurate and reproducible quantitation of homodimers at the 0.2% (w/w) level, with the single-addition method having the promise of higher analytical throughput.
引用
收藏
页码:10475 / 10482
页数:8
相关论文
共 50 条
  • [31] Quantitation of Soybean Allergens Using Tandem Mass Spectrometry
    Houston, Norma L.
    Lee, Dong-Gi
    Stevenson, Severin E.
    Ladics, Gregory S.
    Bannon, Gary A.
    McClain, Scott
    Privalle, Laura
    Stagg, Nicola
    Herouet-Guicheney, Corinne
    MacIntosh, Susan C.
    Thelen, Jay J.
    JOURNAL OF PROTEOME RESEARCH, 2011, 10 (02) : 763 - 773
  • [32] Recombinant staphylokinase variants with altered immunoreactivity .4. Identification of variants with reduced antibody induction but intact potency
    Collen, D
    Stockx, L
    Lacroix, H
    Suy, R
    Vanderschueren, S
    CIRCULATION, 1997, 95 (02) : 463 - 472
  • [33] Development of liquid chromatography/mass spectrometry based screening assay for PfTrxR inhibitors using relative quantitation of intact thioredoxin
    Munigunti, Ranjith
    Calderon, Angela I.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (17) : 2051 - 2056
  • [34] Insights from native mass spectrometry and ion mobility-mass spectrometry for antibody and antibody-based product characterization
    Terral, Guillaume
    Beck, Alain
    Cianferani, Sarah
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1032 : 79 - 90
  • [35] Antibody-Free Detection and Quantitation of TDP-43 by Mass Spectrometry
    Zhengi, Yu Zi
    DeMarco, Mari
    NEUROLOGY, 2016, 86
  • [36] The rapid identification of intact microorganisms using mass spectrometry
    Claydon, MA
    Davey, SN
    EdwardsJones, V
    Gordon, DB
    NATURE BIOTECHNOLOGY, 1996, 14 (11) : 1584 - 1586
  • [37] Characterizing Intact IgA2 Antibody and Its Size Variants Using Native Mass Spectrometry and a Tandem MS-based Charge Reduction Approach
    Chen Q.-R.
    Chaihu L.-X.
    Chen T.
    Wang G.-B.
    Journal of Chinese Mass Spectrometry Society, 2022, 43 (06) : 697 - 706
  • [38] Characterization of charge variants for antibody-based biopharmaceuticals by mass spectrometry
    Guillarme, Davy
    Hage, David S.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2019, 1134
  • [39] Characterization of a recombinant monoclonal antibody by mass spectrometry combined with liquid chromatography
    Fernández, LEM
    Kalume, DE
    Calvo, L
    Mallo, MF
    Vallin, A
    Roepstorff, P
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 752 (02): : 247 - 261
  • [40] AN APPLICATION OF GAS-CHROMATOGRAPHY MASS-SPECTROMETRY TO THE QUANTITATION OF SUBSTANCES AND THEIR LABELED VARIANTS
    SCHRAMM, W
    LOUTON, T
    SCHILL, W
    HOPPEN, HO
    BIOMEDICAL MASS SPECTROMETRY, 1980, 7 (06): : 273 - 276