DIAGNOSTIC PERFORMANCE OF ULTRASOUND SHEAR WAVE ELASTOGRAPHY IN SOLID SMALL (≤4 CM) RENAL PARENCHYMAL MASSES

被引:11
|
作者
Cai, Yingyu [1 ]
Li, Fan [1 ]
Li, Zhaojun [1 ]
Du, Lianfang [1 ]
Wu, Rong [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Dept Ultrasound, Sch Med, 100 Haining Rd, Shanghai 200080, Peoples R China
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2019年 / 45卷 / 09期
关键词
Kidney neoplasms; Ultrasonography; Shear wave elastography; Differential diagnosis; Renal cell carcinoma; CONTRAST-ENHANCED ULTRASOUND; FORCE IMPULSE ELASTOGRAPHY; WFUMB GUIDELINES; CELL CARCINOMA; CLINICAL-USE; MINIMAL FAT; ANGIOMYOLIPOMA; KIDNEY; RECOMMENDATIONS; LESIONS;
D O I
10.1016/j.ultrasmedbio.2019.05.010
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim of the study was to analyze the diagnostic performance of shear wave elastography (SWE) in differentiating between malignant and benign solid renal parenchymal masses <= 4 cm, compared with conventional ultrasound. A total of 20 healthy volunteers and 117 patients had been included in this study. Conventional ultrasound and SWE were performed in all volunteers and patients. The elasticity of healthy cortex and the elastic parameters of tumors such as mean elasticity (E-mean), minimum elasticity (E-min), maximum elasticity (E-max), standard deviation and elasticity ratio of the lesion to surrounding cortex (E-ratio) were measured on SWE images. Diagnostic performance of SWE was compared with that of conventional ultrasound. The cortical elasticity values of healthy right and left kidneys were 4.7 +/- 1.7 and 4.5 +/- 1.5 kPa, respectively. Of the 117 renal tumors, 68 were renal cell carcinomas (RCCs) and 49 were benign. E-mean, E-min and E-ratio were significantly lower in RCCs compared with benign lesions: E-mean 7.2 +/- 2.5 kPa versus 10.0 +/- 2.4 kPa, E-min 2.5 +/- 2.4 kPa versus 5.6 +/- 2.3 kPa, E-ratio 1.6 +/- 0.5 versus 2.2 +/- 0.6 (all p values < 0.001). The cutoff values of 9.15 kPa for E-mean, 3.55 kPa for E-min and 1.99 for E-ratio had the highest areas under the receiver operating characteristics curve (0.801 for E-mean, 0.832 for E-min and 0.806 for E-ratio). Combining E-mean, E-min and E-ratio with conventional ultrasound improved the specificity for predicting RCCs to 87.8%, but the sensitivity was not increased. (C) 2019 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
下载
收藏
页码:2328 / 2337
页数:10
相关论文
共 50 条
  • [31] Classification of breast masses on ultrasound shear wave elastography using convolutional neural networks
    Fujioka, Tomoyuki
    Katsuta, Leona
    Kubota, Kazunori
    Mori, Mio
    Kikuchi, Yuka
    Kato, Arisa
    Oda, Goshi
    Nakagawa, Tsuyoshi
    Kitazume, Yoshio
    Tateishi, Ukihide
    ULTRASONIC IMAGING, 2020, 42 (4-5) : 213 - 220
  • [32] Comparison of the diagnostic performance of Real time tissue elastography as strain elastography with that of FibroScan as shear wave elastography
    Morikawa, Hiroyasu
    Uchida, Sawako K.
    Fujii, Hideki
    Hagihara, Atsushi
    Kawamura, Etsushi
    Iwai, Shuji
    Enomoto, Masaru
    Murakami, Yoshiki
    Tamori, Akihiro
    Kawada, Norifumi
    HEPATOLOGY, 2013, 58 : 955A - 955A
  • [33] Combination of shear wave elastography and BI-RADS in identification of solid breast masses
    Xue Zheng
    Fei Li
    Zhi-Dong Xuan
    Yu Wang
    Lei Zhang
    BMC Medical Imaging, 21
  • [34] Combination of shear wave elastography and BI-RADS in identification of solid breast masses
    Zheng, Xue
    Li, Fei
    Xuan, Zhi-Dong
    Wang, Yu
    Zhang, Lei
    BMC MEDICAL IMAGING, 2021, 21 (01)
  • [35] Diagnostic Performance of Shear Wave Elastography of the Breast According to Scanning Orientation
    Kim, Solip
    Choi, SeonHyeong
    Choi, Yoonjung
    Kook, Shin-Ho
    Park, Hee Jin
    Chung, Eun Chul
    JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (10) : 1797 - 1804
  • [36] Diagnostic Performance of Shear Wave Elastography in Patients With Autoimmune Liver Disease
    Li, Changtian
    Dhyani, Manish
    Bhan, Atul K.
    Grajo, Joseph R.
    Pratt, Daniel S.
    Gee, Michael S.
    Samir, Anthony E.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (01) : 103 - 111
  • [37] Ultrasound shear wave elastography for the evaluation of renal pathological changes in adult patients
    Leong, Sook Sam
    Jalalonmuhali, Maisarah
    Nazri, Mohammad
    Ng, Kwan Hoong
    Vijayananthan, Anushya
    Hisham, Ranitha
    Wong, Jeannie Hsiu Ding
    BRITISH JOURNAL OF RADIOLOGY, 2023, 96 (1144):
  • [38] Comparison of the Diagnostic Performance of Strain Elastography and Shear Wave Elastography for the Diagnosis of Carpal Tunnel Syndrome
    Park, Eun Joo
    Hahn, Seok
    Yi, Jisook
    Shin, Kyong Jin
    Lee, Yedaun
    Lee, Ho-Joon
    JOURNAL OF ULTRASOUND IN MEDICINE, 2021, 40 (05) : 1011 - 1021
  • [39] Are growth patterns on MRI in small (< 4 cm) solid renal masses useful for predicting benign histology?
    Robert S. Lim
    Matthew D. F. McInnes
    Mahadevaswamy Siddaiah
    Trevor A. Flood
    Luke T. Lavallee
    Nicola Schieda
    European Radiology, 2018, 28 : 3115 - 3124
  • [40] Evaluation of Two Ultrasound Systems for Shear Wave Elastography Measurements of Small Targets
    Long, Z.
    Tradup, D.
    Eby, S.
    Song, P.
    Chen, S.
    Glazebrook, K.
    Hangiandreou, N.
    MEDICAL PHYSICS, 2017, 44 (06) : 3239 - 3239