DIAGNOSTIC PERFORMANCE OF ULTRASOUND SHEAR WAVE ELASTOGRAPHY IN SOLID SMALL (≤4 CM) RENAL PARENCHYMAL MASSES

被引:11
|
作者
Cai, Yingyu [1 ]
Li, Fan [1 ]
Li, Zhaojun [1 ]
Du, Lianfang [1 ]
Wu, Rong [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Dept Ultrasound, Sch Med, 100 Haining Rd, Shanghai 200080, Peoples R China
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2019年 / 45卷 / 09期
关键词
Kidney neoplasms; Ultrasonography; Shear wave elastography; Differential diagnosis; Renal cell carcinoma; CONTRAST-ENHANCED ULTRASOUND; FORCE IMPULSE ELASTOGRAPHY; WFUMB GUIDELINES; CELL CARCINOMA; CLINICAL-USE; MINIMAL FAT; ANGIOMYOLIPOMA; KIDNEY; RECOMMENDATIONS; LESIONS;
D O I
10.1016/j.ultrasmedbio.2019.05.010
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim of the study was to analyze the diagnostic performance of shear wave elastography (SWE) in differentiating between malignant and benign solid renal parenchymal masses <= 4 cm, compared with conventional ultrasound. A total of 20 healthy volunteers and 117 patients had been included in this study. Conventional ultrasound and SWE were performed in all volunteers and patients. The elasticity of healthy cortex and the elastic parameters of tumors such as mean elasticity (E-mean), minimum elasticity (E-min), maximum elasticity (E-max), standard deviation and elasticity ratio of the lesion to surrounding cortex (E-ratio) were measured on SWE images. Diagnostic performance of SWE was compared with that of conventional ultrasound. The cortical elasticity values of healthy right and left kidneys were 4.7 +/- 1.7 and 4.5 +/- 1.5 kPa, respectively. Of the 117 renal tumors, 68 were renal cell carcinomas (RCCs) and 49 were benign. E-mean, E-min and E-ratio were significantly lower in RCCs compared with benign lesions: E-mean 7.2 +/- 2.5 kPa versus 10.0 +/- 2.4 kPa, E-min 2.5 +/- 2.4 kPa versus 5.6 +/- 2.3 kPa, E-ratio 1.6 +/- 0.5 versus 2.2 +/- 0.6 (all p values < 0.001). The cutoff values of 9.15 kPa for E-mean, 3.55 kPa for E-min and 1.99 for E-ratio had the highest areas under the receiver operating characteristics curve (0.801 for E-mean, 0.832 for E-min and 0.806 for E-ratio). Combining E-mean, E-min and E-ratio with conventional ultrasound improved the specificity for predicting RCCs to 87.8%, but the sensitivity was not increased. (C) 2019 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
下载
收藏
页码:2328 / 2337
页数:10
相关论文
共 50 条
  • [11] Differentiating solid breast masses: comparison of the diagnostic efficacy of shear wave elastography and magnetic resonance imaging
    Farghadani, Maryam
    Barikbin, Rozbeh
    Rezaei, Mostafa Haji
    Hekmatnia, Ali
    Aalinezhad, Marzieh
    Zare, Hosein
    DIAGNOSIS, 2021, 8 (03) : 382 - 387
  • [12] Usability of Transthoracic Shear Wave Elastography in Differentiation of Subpleural Solid Masses
    Ozgokce, Mesut
    Yavuz, Alpaslan
    Akbudak, Ibrahim
    Durmaz, Fatma
    Uney, Ibrahim
    Aydin, Yener
    Yildiz, Hanifi
    Batur, Abdussamet
    Arslan, Harun
    Dundar, Ilyas
    ULTRASOUND QUARTERLY, 2018, 34 (04) : 233 - 237
  • [13] Quantitative shear wave elastography for noninvasive assessment of solid pancreatic masses
    Xie, Juan
    Liu, Hui
    Liu, Wen-sheng
    Li, Jia-wei
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2020, 74 (02) : 179 - 187
  • [14] Shear Wave Elastography: Is It a Valuable Additive Method to Conventional Ultrasound for the Diagnosis of Small (≤2 cm) Breast Cancer?
    Kim, So Jung
    Ko, Kyung Hee
    Jung, Hae Kyoung
    Kim, Hyerin
    MEDICINE, 2015, 94 (42) : e1540
  • [15] Re: Enhancement Threshold of Small (&lt; 4 cm) Solid Renal Masses on CT
    Siegel, Cary
    JOURNAL OF UROLOGY, 2016, 196 (03): : 687 - 687
  • [16] Re: Enhancement Threshold of Small (&lt; 4 cm) Solid Renal Masses on CT
    Siegel, Cary
    JOURNAL OF UROLOGY, 2016, 196 (04): : 1043 - 1043
  • [17] Diagnostic role of shear wave elastography for differentiating benign and malignant breast masses
    Sravani, Nichanametla
    Ramesh, Ananthakrishnan
    Sureshkumar, Sathasivam
    Vijayakumar, Chellappa
    Abdulbasith, K. M.
    Balasubramanian, Gopal
    Toi, Pampa Ch
    SA JOURNAL OF RADIOLOGY, 2020, 24 (01):
  • [18] Diagnostic utility of strain and shear wave ultrasound elastography in differentiation of benign and malignant solid breast lesions
    Ahmed Tohamy Ahmed
    Egyptian Journal of Radiology and Nuclear Medicine, 51
  • [19] Diagnostic utility of strain and shear wave ultrasound elastography in differentiation of benign and malignant solid breast lesions
    Ahmed, Ahmed Tohamy
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2020, 51 (01):
  • [20] Diagnostic Performance of Contrast-Enhanced Ultrasound (CEUS) in the Evaluation of Solid Renal Masses
    Geyer, Thomas
    Schwarze, Vincent
    Marschner, Constantin
    Schnitzer, Moritz L.
    Froelich, Matthias F.
    Ruebenthaler, Johannes
    Clevert, Dirk-Andre
    MEDICINA-LITHUANIA, 2020, 56 (11): : 1 - 8