DIAGNOSTIC PERFORMANCE OF ULTRASOUND SHEAR WAVE ELASTOGRAPHY IN SOLID SMALL (≤4 CM) RENAL PARENCHYMAL MASSES

被引:11
|
作者
Cai, Yingyu [1 ]
Li, Fan [1 ]
Li, Zhaojun [1 ]
Du, Lianfang [1 ]
Wu, Rong [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Dept Ultrasound, Sch Med, 100 Haining Rd, Shanghai 200080, Peoples R China
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2019年 / 45卷 / 09期
关键词
Kidney neoplasms; Ultrasonography; Shear wave elastography; Differential diagnosis; Renal cell carcinoma; CONTRAST-ENHANCED ULTRASOUND; FORCE IMPULSE ELASTOGRAPHY; WFUMB GUIDELINES; CELL CARCINOMA; CLINICAL-USE; MINIMAL FAT; ANGIOMYOLIPOMA; KIDNEY; RECOMMENDATIONS; LESIONS;
D O I
10.1016/j.ultrasmedbio.2019.05.010
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim of the study was to analyze the diagnostic performance of shear wave elastography (SWE) in differentiating between malignant and benign solid renal parenchymal masses <= 4 cm, compared with conventional ultrasound. A total of 20 healthy volunteers and 117 patients had been included in this study. Conventional ultrasound and SWE were performed in all volunteers and patients. The elasticity of healthy cortex and the elastic parameters of tumors such as mean elasticity (E-mean), minimum elasticity (E-min), maximum elasticity (E-max), standard deviation and elasticity ratio of the lesion to surrounding cortex (E-ratio) were measured on SWE images. Diagnostic performance of SWE was compared with that of conventional ultrasound. The cortical elasticity values of healthy right and left kidneys were 4.7 +/- 1.7 and 4.5 +/- 1.5 kPa, respectively. Of the 117 renal tumors, 68 were renal cell carcinomas (RCCs) and 49 were benign. E-mean, E-min and E-ratio were significantly lower in RCCs compared with benign lesions: E-mean 7.2 +/- 2.5 kPa versus 10.0 +/- 2.4 kPa, E-min 2.5 +/- 2.4 kPa versus 5.6 +/- 2.3 kPa, E-ratio 1.6 +/- 0.5 versus 2.2 +/- 0.6 (all p values < 0.001). The cutoff values of 9.15 kPa for E-mean, 3.55 kPa for E-min and 1.99 for E-ratio had the highest areas under the receiver operating characteristics curve (0.801 for E-mean, 0.832 for E-min and 0.806 for E-ratio). Combining E-mean, E-min and E-ratio with conventional ultrasound improved the specificity for predicting RCCs to 87.8%, but the sensitivity was not increased. (C) 2019 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:2328 / 2337
页数:10
相关论文
共 50 条
  • [1] Quantitative shear wave ultrasound elastography: initial experience in solid breast masses
    Evans, Andrew
    Whelehan, Patsy
    Thomson, Kim
    McLean, Denis
    Brauer, Katrin
    Purdie, Colin
    Jordan, Lee
    Baker, Lee
    Thompson, Alastair
    [J]. BREAST CANCER RESEARCH, 2010, 12 (06)
  • [2] Quantitative shear wave ultrasound elastography: initial experience in solid breast masses
    Andrew Evans
    Patsy Whelehan
    Kim Thomson
    Denis McLean
    Katrin Brauer
    Colin Purdie
    Lee Jordan
    Lee Baker
    Alastair Thompson
    [J]. Breast Cancer Research, 12
  • [3] Diagnostic Performance of Quantitative Shear Wave Elastography in the Evaluation of Solid Breast Masses: Determination of the Most Discriminatory Parameter
    Au, Frederick Wing-Fa
    Ghai, Sandeep
    Moshonov, Hadas
    Kahn, Harriette
    Brennan, Cressida
    Dua, Hemi
    Crystal, Pavel
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (03) : W328 - W336
  • [4] Performance of Shear Wave Elastography for Differentiation of Benign and Malignant Solid Breast Masses
    Li, Guiling
    Li, De-Wei
    Fang, Yu-Xiao
    Song, Yi-Jiang
    Deng, Zhu-Jun
    Gao, Jian
    Xie, Yan
    Yin, Tian-Sheng
    Ying, Li
    Tang, Kai-Fu
    [J]. PLOS ONE, 2013, 8 (10):
  • [5] Reproducibility and diagnostic performance of shear wave elastography in evaluating breast solid mass
    Hong, Sun
    Woo, Ok Hee
    Shin, Hye Seon
    Hwang, Soon-Young
    Cho, Kyu Ran
    Seo, Bo Kyoung
    [J]. CLINICAL IMAGING, 2017, 44 : 42 - 45
  • [6] CHARACTERIZATION OF TESTICULAR MASSES IN ADULTS: PERFORMANCE OF COMBINED QUANTITATIVE SHEAR WAVE ELASTOGRAPHY AND CONVENTIONAL ULTRASOUND
    Rocher, Laurence
    Criton, Aline
    Gennisson, Jean-Luc
    Creze, Maud
    Albiges, Laurence
    Ferlicot, Sophie
    Bellin, Marie-France
    Izard, Vincent
    Correas, Jean-Michel
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (03): : 720 - 731
  • [7] Diagnostic performance of endorectal ultrasound combined with shear wave elastography for rectal tumors staging
    Dong, Xue-Ying
    Li, Qiang-Mei
    Xue, Wei-Li
    Sun, Jia-Wei
    Zhou, Hang
    Han, Ye
    Zhou, Xian-Li
    Hou, Xiu-Juan
    [J]. CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2023, 84 (04) : 399 - 411
  • [8] Enhancement Threshold of Small (&lt; 4 cm) Solid Renal Masses on CT
    Al Harbi, Fawaz
    Tabatabaeefar, Leila
    Jewett, Michael A.
    Finelli, Anthony
    O'Malley, Martin
    Atri, Mostafa
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (03) : 554 - 558
  • [9] Diagnostic performances of shear wave elastography: which parameter to use in differential diagnosis of solid breast masses?
    Lee, Eun Jung
    Jung, Hae Kyoung
    Ko, Kyung Hee
    Lee, Jong Tae
    Yoon, Jung Hyun
    [J]. EUROPEAN RADIOLOGY, 2013, 23 (07) : 1803 - 1811
  • [10] Diagnostic performances of shear wave elastography: which parameter to use in differential diagnosis of solid breast masses?
    Eun Jung Lee
    Hae Kyoung Jung
    Kyung Hee Ko
    Jong Tae Lee
    Jung Hyun Yoon
    [J]. European Radiology, 2013, 23 : 1803 - 1811